
Catalog excerpts

Rosemount Magnetic Sensor Specifications Long-lasting, reliable performance in even the most challenging applications Applications Process Applications Utility Water-Based Flows High Consistency Slurry Hygienic (Sanitary) High Pressure (Up to ANSI Class 2500) ½ to 36-in 15-900mm Nominal Line Size Standard Accuracy (2) Optional High Accuracy (2) Line sizes up to 120-in (3000mm) available on special request. Consult relevant product data sheet for full accuracy specifications. Process Temp Limits Consult the PDS for specific application velocity limits such as abbrasive slurries. Liner Selection PFA/ PFA+ - Fluoropolymer (5) Polyurethane Liner Selection High temperature chemically aggressive applications. Most common liner - suitable for most applications Improved abrasion resistance liner - good chemically Water applications with limited to no chemicals Oil and gas applications with high pressure, high salinity High temperature chemically aggressive applications. Best for sea water / lower concentration brine solutions Standard liner for Most common streamssuitable debris mining or fluid liner - w/large for most applications 70° C) (-18 to (4) Capable of temperatures up to 355°F (180°C) - Consult factory for details. MS Sensor available starting at 3-in (DN 80) line size. ETFE - Fluoropolymer 1 to 12 inch -20 to 350° F ½ to to 14 inch (25 to 300 mm) (-29 to 177° C) (4) (15 to 350 mm) 1 to 36 inch (25 to 900 mm) ETFE not available on the MS Sensor Limited maximum temperature of 248°F, 120°C. ½ to 16 inch ½ to 8 inch Description to 200 mm) (15 to 400 mm) (15 Standard design. Suitable for most applications including slurries. Used where coating is a concern and no solids are present. -0 to 140° F 1 to 36 inch (-18 to 60° C) (25 to 900 mm) Flat electrode that is flush with the liner to minimize wear and noise in highly abrasive fluids Water applications with limited to no chemicals Flat Head 0-200° F Typically used in medium to high acid concentrations and sea water. 1 to 12 inch (-18 to 93° C) (25 to 300 mm) Typically used in the most aggressive chemical and pulp and paper liquor applications. Typically used in high concentration acids (hydrochloric, hydroflouric). -0 to 176° F 1 to 36 inch Typically used in highto 900 mm) (-18 to 80° C) (25 concentration caustic (sodium, potasium hydroxide). Best Titanium for sea water / lower concentration brine solutions Alternate special materials available upon request. Capable of temperatures up to 355°F (180°C) - Consult factory for details. Local Operator Interface (LOI) 8732E1 to 36 inch 8712E -0 to 158° F (-18 to 70° C) (25 to 900 mm) (11) Integral or Remote Wall Mount Remote Standard liner for mining or fluid streams w/large debris Transmitter Options Linatex Mounting Standard material. Compatible with most water-based applications. Adiprene Alloy 276 Nickel Oil and gas applications with high pressure, high salinity Bullet-Nose Polyurethane Line Size (8750W) ½ to 48 inch (15 to 1,200 mm) Electrode Selection abrasion resistance liner - good chemically Improved Process to 16 inch Line Size (8) to 8 inch Line Size ½ ½ Temp Limits 400 mm) (8705/MS) to 200 mm)(8711) (15 to (15 8782 Wall Mount Remote 8750W Integral, Remote or Wall Mount (6) Fluoropolymer MWP 1000psi. 4-button available on the MS Sensor (7) Limited maximum temperature of 248°F, 4-button or 15-button ETFE not 120°C. Dedicated 15-button Dedicated 15-button MS Sensor available starting at 3-in (DN 80) line size. Output & Communciation Protocols Power Supply Optional Corrosion Protection ©2020 Emerson. All rights reserved. Diagnostic & Enhanced Features Basic Diagnostics - w/ functional electronics and software checks 4-20 mA, HART, Pulse FOUNDATION fieldbus, Profibus PA, Modbus 4-20 mA, HART, 10 kHz Pulse FOUNDATION fieldbus Modbus 4-20 mA, HART, 10 kHz Pulse FOUNDATION fieldbus, Modbus Optional special paint for submersion protection Optional special Off Shore Paint or SST Enclosure Optional ordering codes: DA1/DA2 - HART 4/20 mA D01/DO2 - D
Open the catalog to page 1
Oil and gas applications with high pressure, high salinity Best for sea water / lower concentration brine solutions Linatex Rosemount Magnetic Sensor Specifications Applications Standard liner for mining or fluid streams w/large debris Capable of temperatures up to 355°F (180°C) - Consult factory for details. Process Applications MS Sensor available starting at 3-in (DN 80) line size. Utility Water-Based Flows Electrode Selection High Consistency Slurry Button Type Hygienic (Sanitary) Bullet-Nose High Pressure (Up to ANSI Class 2500) Flat Head Description Used where coating is a concern and...
Open the catalog to page 2All Emerson Automation Solutions - ROSEMOUNT catalogs and technical brochures
-
VPS 53 Vapor Pressure Sensor
2 Pages
-
EasyHeat™ XD Cable Kits
2 Pages
-
FRL Accessories
14 Pages
-
TankRadar Pro
32 Pages
-
Rosemount™ 2140 Level Detector
22 Pages
-
Roxar subsea PIG
2 Pages
-
Roxar subsea Sand monitor
2 Pages
-
Roxar subsea CM10K
2 Pages
-
Roxar PTPT15K
2 Pages
-
Rosemount TankRadar OFC
2 Pages
-
SW-300
4 Pages
-
DL8000
12 Pages
-
DeltaV Analyze
8 Pages
-
AMS Machine Works
4 Pages
-
DeltaV Executive Portal
7 Pages
-
1500XA Gas Chromatograph
8 Pages
-
Rosemount 975UR
4 Pages
-
Rosemount 975HR
4 Pages
-
Rosemount 975UF
4 Pages
-
Rosemount 975MR
4 Pages
-
CT5400 Process Gas Analyzer
4 Pages
-
CT2211 Leak Detection System
4 Pages
-
Desalination of Seawater
2 Pages
-
700XA Process Gas Chromatograph
12 Pages
-
SafeGuard Alarm Controller
2 Pages
-
Safety Monitoring
6 Pages
-
AMS Suite
16 Pages
-
Drinking Water Sht 2V2
2 Pages
-
Line Card
2 Pages
-
Drinking Water Industry
16 Pages
-
Explosion Proof Video Camera
2 Pages
-
Net Safety UV Flame Detector
4 Pages
Archived catalogs
-
UV/IRS Flame Detector
4 Pages
-
UVS Flame Detector
4 Pages