1. Catalogs
  2. Emerson Automation Solutions - ROSEMOUNT
  3. Rosemount E-Series Magnetic Flowmeters

Rosemount E-Series Magnetic Flowmeters

Rosemount E-Series Magnetic Flowmeters

Rosemount E-Series Magnetic Flowmeters

Product catalog summary
Introduction
The document discusses the Rosemount E-Series Magnetic Flowmeters, highlighting their impact on installation, maintenance, and verification processes. The E-Series technology is designed to enhance process management by ensuring reliable flow measurement, improving throughput and quality, and reducing maintenance costs.

Key Features and Benefits
  • Reliability and Availability: The E-Series flowmeters are designed to withstand moisture, vibration, and environmental changes, ensuring reliable operation. They are tested before shipping to guarantee readiness for application.
  • Robust Construction: The flowmeters feature dual compartments and local operator interface technology to prevent moisture ingress and maintain safe configuration in hazardous environments.
  • Superior Accuracy: The E-Series offers a two-fold improvement in accuracy over traditional flowmeters, with standard accuracy of 0.25% +/- 1mm/s and an option for 0.15% +/- 1mm/s.
  • Diagnostics: Advanced diagnostics simplify installation, maintenance, and troubleshooting by providing actionable feedback and verifying meter health throughout its lifecycle.

Installation and Maintenance
  • Simplified Installation: The E-Series includes ground and wiring fault detection diagnostics to ensure correct installation.
  • Improved Process Control: High process noise detection allows for adjustments to stabilize readings, improving process control without adding dead-time.
  • Reduced Maintenance: Emerson meter verification confirms the health of the flowmeter without the need for external equipment.

Product Offering
The E-Series offers a comprehensive range of electrode and liner materials, process connections, and enhanced features to meet diverse industry needs. Various models are available, each suited for specific applications and accuracy requirements.

Conclusion
The Rosemount E-Series Magnetic Flowmeters provide industry-leading performance, reliability, and diagnostics, making them a valuable asset for process industries seeking to optimize operations and reduce costs.
See more

Catalog excerpts

Rosemount E-Series Magnetic Flowmeters-1

Rosemount E-Series Magnetic Flowmeters Making a difference for your process

 Open the catalog to page 1
Rosemount E-Series Magnetic Flowmeters-2

E-Series technology makes the difference Rosemount E-Series technology really does make a difference in how you install, maintain and verify your magnetic flowmeters, allowing you to better manage your process. Availability is critical to a profitable operation Keeping the process running and safe is fundamental to a successful operation. If your flow measurement is unreliable, it can impact your process and shut down your facility. E-Series makes it easier, so you know it is ready to perform in your application. In addition, E-Series diagnostics provide insight into process dynamics and meter...

 Open the catalog to page 2
Rosemount E-Series Magnetic Flowmeters-3

Reliability improves availability Superior accuracy for improved process control Inaccurate flow measurement makes process control and optimization difficult. In addition to reference accuracy, inadequate straight pipe runs, ambient temperature effects and digital to analog (D to A) conversion errors all have an impact on the measurement accuracy achieved in the field. Keeping your process running safely with reliable measurements is critical. Moisture, vibration and changing environmental conditions all work to undermine the reliability of your magnetic flowmeter and the resulting measurement....

 Open the catalog to page 3
Rosemount E-Series Magnetic Flowmeters-4

Diagnostics simplify your life A noisy flow measurement is a common issue in applications where there is a slurry, entrained gas, or an active chemical reaction. E-Series high process noise detection diagnoses these causes and provides a means to remove the variability from your flow measurement. When high process noise is detected, simply adjust from the standard coil drive frequency (5 Hz) to the high coil drive frequency (37 Hz). This will stabilize readings without adding dead-time to your control loop, allowing for tighter set-points and improved process control. Improve process control...

 Open the catalog to page 4
Rosemount E-Series Magnetic Flowmeters-5

Diagnostics when you want them Simplify access to E-Series diagnostics With E-Series Magnetic Flowmeters from Rosemount, enabling diagnostics in the field is easy. Every E-Series transmitter has the capability to field license the advanced diagnostics allowing you to take advantage of the diagnostics when you need them. The Rosemount E-Series Magnetic Flowmeters with the Smart Wireless THUM adapter powers the PlantWeb® digital plant architecture by delivering more advanced field intelligence for better decision-making to help you achieve unparalleled efficiency and productivity.

 Open the catalog to page 5
Rosemount E-Series Magnetic Flowmeters-6

Step 3: Electrode Type and Material Selection Electrode Type Button E-Series delivers a wide offering of electrode and liner materials, process connections, and enhanced features to meet the many needs of the process industries. Standard electrode design. Use for most applications, especially where abrasion is a concern. Has fair resistance to coating which can be improved by properly sizing flowtube sensor. Comprehensive magnetic flowmeter offering Application Notes Use where coating is a concern and no solids are present. Bullet-nose electrode should not be used in abrasive or slurry applications...

 Open the catalog to page 6
Rosemount E-Series Magnetic Flowmeters-7

The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of the Emerson Process Management group of companies. All other marks are the property of their respective owners. ©2010 Rosemount Inc. All rights reserved. Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906 8888 F (952) 949 7001 www.rosemount.com Emerson Process Management Flow Neonstraat 1 6718 WX Ede The Netherlands...

 Open the catalog to page 7

All Emerson Automation Solutions - ROSEMOUNT catalogs and technical brochures

  1. FRL Accessories

    14  Pages

  2. TankRadar Pro

    32  Pages

  3. Roxar PTPT15K

    2  Pages

  4. SW-300

    4  Pages

  5. DL8000

    12  Pages

  6. AMS Suite

    16  Pages

  7. Line Card

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.