FMC Biopolymer reduces operating expenses more than 80% with PERpH-X™ sensors. RESULTS • 80% Reduced Maintenance Cost • $200K Yearly OpEx Savings • Measurement Deadtime reduced by 70% APPLICATION pH in a Chemical Processing Plant CUSTOMER FMC Biopolymers in Rockland, Maine, USA CHALLENGE FMC makes ingredients for consumer products such as toothpaste, baking mixes, and other food products. The plant makes carrageenan out of seaweed using a sequence of chemical processing steps that starts with soaking the seaweed at 200°F. The processing tanks and lines are regularly subjected to both acid and base clean in place (CIP) solutions. pH measurement in the recirculation line of the modification tank is used to control acid addition and keep the pH in the range of 7.5 to 8. pH values in this range minimize downstream buildup on filters. Unfortunately, conventional pH electrodes were only lasting less than 1 week in this application, so FMC had installed a triple redundant system to make sure the pH reading is continuously available. The process in the modification tank is a thick brown gel that can be difficult to remove completely from the pH sensor and tends to foul the reference junction, causing the sensor to become nonresponsive. Maintenance on the pH sensor included cleaning the sensor, replacing the glass electrode every week, replacing the reference electrode every 2 weeks, and replacing the pH assembly every 6 months. Every time the sensor was rebuilt, the pH reading required recalibration, which took an average of 30 minutes to complete. Mike McNeil, E/I Planning Engineer at FMC had investigated several pH vendors but was still looking for a more reliable measurement. He For more information: www.EmersonProcess.com/QBR www.raihome.com Rosemount Analytical’s PERpH-X™ model 3400HTVP sensor and loop powered transmitter model XMT were installed in May 2006 to run side by side with 3 sensors from another manufacturer to see if they could provide better results.
Open the catalog to page 1estimated that 20 man-hours a week were required to keep the seven pH loops operating. SOLUTION Rosemount Analytical’s PERpH-X model 3400HTVP sensor and loop powered transmitter model XMT were installed in May 2006 to run side by side with 3 sensors from another manufacturer to see if they could provide better results. FMC had been testing so many different pH products that it was quite simple to install a new test sensor. Paul Geilser of FMC said “we have tested everybody’s pH probe over the last 15 years – we usually trash them within 24 hours.” After 3 months of operation, FMC was amazed...
Open the catalog to page 2All Emerson Automation Solutions - ROSEMOUNT catalogs and technical brochures
-
VPS 53 Vapor Pressure Sensor
2 Pages
-
EasyHeat™ XD Cable Kits
2 Pages
-
FRL Accessories
14 Pages
-
TankRadar Pro
32 Pages
-
Rosemount™ 2140 Level Detector
22 Pages
-
Roxar subsea PIG
2 Pages
-
Roxar subsea Sand monitor
2 Pages
-
Roxar subsea CM10K
2 Pages
-
Roxar PTPT15K
2 Pages
-
Rosemount TankRadar OFC
2 Pages
-
SW-300
4 Pages
-
DL8000
12 Pages
-
DeltaV Analyze
8 Pages
-
AMS Machine Works
4 Pages
-
DeltaV Executive Portal
7 Pages
-
1500XA Gas Chromatograph
8 Pages
-
Rosemount 975UR
4 Pages
-
Rosemount 975HR
4 Pages
-
Rosemount 975UF
4 Pages
-
Rosemount 975MR
4 Pages
-
CT5400 Process Gas Analyzer
4 Pages
-
CT2211 Leak Detection System
4 Pages
-
Desalination of Seawater
2 Pages
-
700XA Process Gas Chromatograph
12 Pages
-
SafeGuard Alarm Controller
2 Pages
-
Safety Monitoring
6 Pages
-
AMS Suite
16 Pages
-
Drinking Water Sht 2V2
2 Pages
-
Line Card
2 Pages
-
Drinking Water Industry
16 Pages
-
Explosion Proof Video Camera
2 Pages
-
Net Safety UV Flame Detector
4 Pages
Archived catalogs
-
UV/IRS Flame Detector
4 Pages
-
UVS Flame Detector
4 Pages