Millennium II M21 Transmitter - Single Channel Universal Gas Monitoring
4Pages

{{requestButtons}}

Catalog excerpts

Millennium II M21 Transmitter - Single Channel Universal Gas Monitoring - 1

Millennium II Gas Detection Transmitter Product Data Sheet Single Channel Universal Gas Monitoring “SMART” Gas Detector Series The Millennium II (M21) single channel universal transmitters have been engineered from the ground-up to include the innovative features that managers and operators in the field demand, while providing rock solid day-to-day operation, even in the most extreme conditions. The Millennium II redefines what you expect from a fixed gas detection solution. SMART Sensor Technology — Compatible with All Sensor Types (Infrared, Catalytic Bead, Electrochemical, and NE-MOS) Wide Voltage Range Allows For Greater Stability and System Compatibility Intuitive Menu System Provide Operators with a Non-intrusive Set-up and Calibration Interface Lowest Power Consumption Available Field Selectable Gas Curves and Ranges Diagnostics with Event and Data Logging Full Long Range (+2000ft.) Sensor Separation SMART Sensor Technology Superior OLED Display The transmitter can be fitted with a wide range of toxic and/ or combustible gas sensors. SMART (Self Monitoring Analysis and Reporting Technology) sensors are pre-calibrated and easily connected to the transmitter which recognizes a newly fitted sensor, automatically uploading it’s specific configuration profile. The only full graphic OLED display available, easy to read in all ambient lighting conditions and operates down to -55°C! Digital Communications Sensor and transmitter continuously communicate digitally, giving you the confidence of stable, accurate protection with fast response times even over long separation distances. Global Certifications The Millennium II is approved to international hazardous area safety standards for operation and performance. Easy To Use Menus English, French, Portuguese or Spanish display languages included. The full text menu makes installation, operation and calibration simple. No manual necessary! PMS - Uncoated Analog, Relay, Modbus RS485 RTU & HART® Multiple communication protocols are available combined with Relays to allow the M21 Transmitter to work seamlessly with your system. Field-proven Sensor Innovations All of our sensors are engineered to be fast and reliable with field-proven performance in the harshest industrial conditions possible. These include Nano-Enhanced Metal Oxide Semiconductor (NE-MOS) toxic gas sensors that do not “fall asleep” and a full range of fast response Electrochemical toxic gas sensors. For combustible gas detection, poisonresistant Catalytic Bead technology with SensorGuard, which greatly prolongs sensor life and Infrared sensor technology utilizing a dual beam design with no mirrors that can become contaminated (“fogged up”) or misaligned.

Open the catalog to page 1
Millennium II M21 Transmitter - Single Channel Universal Gas Monitoring - 2

Millennium II Gas Detection Transmitter Product Data Sheet “SMART” Gas Detector Series Electrical Power Consumption Voltage Range ORDERING INFORMATION 2.4W @ 24 or 12 Vdc (average - varies by sensor types/quantities) Single Channel - Analog & Relay Organic LED (OLED), Power/Status LED’s Single Channel - Analog Single Channel - Analog & Modbus M21-ARD* Single Channel - Analog & Relay & Modbus Single Channel - Analog & Solid State Relays -55°C to +85°C (-67°F to +185°F) Certified Operating Range Single Channel - Analog & HART Relative Humidity Single Channel - Analog & HART & Relay Enclosures...

Open the catalog to page 2
Millennium II M21 Transmitter - Single Channel Universal Gas Monitoring - 3

Millennium II Gas Detection Transmitter Product Data Sheet Separation Boxes & Accessories SEPARATION BOXES “SMART” Gas Detector Series Class 1, Division 1, Groups BCD - Class 1, Zone 1 -- Enclosure rated NEMA 4X, IP67 (See man-0081 for full specifications) JB-MPD-S Digital Output - Stainless Steel Digital Output - Aluminum Universal duct mount assembly with 1M inlet sampling pipe - Stainless Steel Universal duct mount assembly with 1.5M inlet sampling pipe - Stainless Steel Universal duct mount assembly - Stainless Steel 1M extension - for use with UDM-001 & UDM-002 - Stainless Steel 1.5M...

Open the catalog to page 3
Millennium II M21 Transmitter - Single Channel Universal Gas Monitoring - 4

Millennium II Gas Detection Transmitter Product Data Sheet FCD PDS M21 Gas Detection Transmitter November 2013 Emerson Process Management Calgary, Alberta, Canada T1Y7J7 BLOC LIKE SHARE ©2013 Emerson Process Management. All rights reserved. Emerson Process Management, Rosemount Analytical, and Net Safety Monitoring are marks of Emerson Process Management group of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be...

Open the catalog to page 4