C2+ Measurement Solutions for Turbine Control Using an X-STREAM Enhanced Analyzer

C2+ Measurement Solutions for Turbine Control Using an X-STREAM Enhanced Analyzer

C2+ Measurement Solutions for Turbine Control Using an X-STREAM Enhanced Analyzer

Product catalog summary
Background
Industrial power markets require rapid control to optimize plant performance and prevent turbine damage. The increase in unconventional natural gas sources, such as shale, has heightened the need for maintaining turbine efficiency. Variations in higher hydrocarbons (C2+) can be significant, with fluctuations recorded between 10% to 16% within a minute. Turbines must be flexible to handle these variations over a wide range of loads, especially during peak demand.

Solution
The solution involves using an X-STREAM Enhanced Analyzer with a 0–100% CH4 NDIR bench and a 0–25% C2H6 NDIR bench. This setup provides high selectivity for CH4 against C2H6, C3H8, C4H10, and CO2. The C2H6 bench measures C2H6, C3H8, and C4H10 with specific response factors and corrects for CH4 through cross compensation. Best accuracy is achieved in natural gas mixtures with CH4 as the major component and C2+ up to 20%.

Combination with Other Measurements
CO2 content can be measured alongside hydrocarbons for better control and calorific value calculations. The Wobbe Index can be calculated using relative density from concentration values or an external density signal. Additional channels may be needed for calorific value calculations, which aid in rapid operational adjustments.

Application
Methane and higher hydrocarbons behave differently during combustion, posing challenges for control and optimization in combined cycle turbines. A process gas analyzer (PGA) with specific optical benches and filters provides continuous measurement and rapid response. An approximate calorific value (BTU) can be provided, though it may be underestimated if higher hydrocarbons are present.

System Configuration
Methane (C1) and Ethane plus (C2+) measurements often occur in hazardous areas, recommending the use of an X-STREAM Enhanced flameproof analyzer by Rosemount Analytical.

Analyzer Calibration
Calibration of the X-STREAM Enhanced analyzer measurement cells can be executed manually or automatically using calibration solenoid valves.

Sample Conditioning
The sample system includes a flanged sample probe, heated pressure reduction station, sample filtration, and sample flow control, as shown in the flow diagram.

Contact Information
Contact details for Emerson Process Management across various regions are provided for further inquiries.
See more

Catalog excerpts

C2+ Measurement Solutions for Turbine Control Using an X-STREAM Enhanced Analyzer-1

Application Note C2+ Measurement Solutions for Turbine Control Using an X-STREAM Enhanced Analyzer Background Industrial power markets covering multiple energy sources require rapid control in order to optimize plant performance and prevent costly turbine damage. Lower emission requirements and varying fuel sources due to the increase in unconventional natural gas sources, such as shale, have created a higher priority on maintaining turbine efficiency. Although the plants gas sources are predominantly made up of methane, extensive variations in higher hydrocarbons (C2+) typically exist. In fact, in some cases, over 18 % variation has been recorded with fluctuations from 10% to 16 % within one minute. In addition, turbines have to be more flexible and need to present the above criteria over a wide range of loads because gas turbine power plants are often used only for peak loads. X-STREAM XE Typical Power Plant Turbine Application Methane and higher hydrocarbons like ethane and propane behave differently during combustion. Particularly for combined cycle turbines with lower emissions, variability of fuel sources presents challenges for control and optimization. Although a gas chromatograph can provide all needed measurements, speed of response is sometimes not sufficient for such control. A process gas analyzer (PGA) with a specific configuration of optical benches and filters provides continuous measurement and the rapid response necessary. In addition, an approximate calorific value (BTU) can be provided as long as the higher hydrocarbons are low in content. If this is not the case, the BTU value will be underestimated but never overestimated. Such values cannot be used for custody transfer but may be adequate to prevent turbine damage and optimize performance. If the variation of C2+ in the fuel sources are known, the error can be greatly minimized. Table 1 - Typical Gas Composition in Natural Gas Power Plants Component Butane Carbon Dioxide Oxygen Nitrogen Hydrogen Sulphide Rare Gases Solution With a 0–100 % CH4 NDIR bench measuring 7.85 µm, and a 0–25 % C2H6 NDIR bench measuring 6.6 µm, we designed a solution which provides a high selectivity for CH4 against C2H6, C3H8 and C4H10 as well as CO2. The C2H6 bench measures C2H6, C3H8 and C4H10 with response factors of 1.0, 1.0, 1.1 and gives a low response from CH4, internally corrected by cross compensation. Best accuracy is achieved in Natural Gas mixtures with CH4 as a major component, C2+ up to 20 %, and low water content. Combination with Other Measurements Since CO2 content also varies in fuel sources, this measurement may be combined with the hydrocarbon values for better control and calorific value calculations. Carbon dioxide measurement utilizing optical non-dispersive infrared (NDIR) technology can also be added to the X-STREAM Enhanced analyzer configuration. A calculation of the Wobbe Index is also possible utilizing a calculated relative density from the concentration values or by utilizing an external density signal. Calorific value calculations might require integration of additional channels. As with the BTU calculation, this is not for custody transfer but aids in rapid adjustments to operations if fluctuations occur.

 Open the catalog to page 1
C2+ Measurement Solutions for Turbine Control Using an X-STREAM Enhanced Analyzer-2

System Configuration Methane (CI) and Ethane plus (C2+) measurements for natural gas power applications often take place in hazardous areas. Therefore an X-STREAM Enhanced flameproof analyzer by Rosemount Analytical Sample Conditioning Figure 2 below shows a flow diagram of the recommended analyzer system. Sample extraction, transport, and conditioning occurs using Rosemount Analytical Sample System Modules which include a flanged sample probe, heated pressure reduction station, sample filtration, and sample flow control. Figure 2 - Sample System Flow Diagram Analyzer Calibration Zeroing and...

 Open the catalog to page 2

All Emerson Automation Solutions - ROSEMOUNT catalogs and technical brochures

  1. FRL Accessories

    14  Pages

  2. TankRadar Pro

    32  Pages

  3. Roxar PTPT15K

    2  Pages

  4. SW-300

    4  Pages

  5. DL8000

    12  Pages

  6. AMS Suite

    16  Pages

  7. Line Card

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.