Overview: The PI-01V is an isotropic dual band electric field probe designed for selective RF measurements, particularly useful for cell phone tower certification. It operates within the 900/1900 MHz frequency range and is compatible with Smart Fieldmeter® and Smart Fieldmeter® Digital meters.
Main Specifications:
  • Sensor Type: Diode based, 3-axial isotropic sensor.
  • Sensitivity: High sensitivity at 0.2 V/m.
  • Linearity: +/- 0.5 dB within 1-400 V/m range.
  • Dynamic Range: Greater than 66 dB in a single range.
  • Frequency Range: Selective frequency range of 900-1900 MHz.
  • Calibration Frequency Ranges: 925-960 MHz and 1805-1880 MHz.
  • Response Flatness: +/- 1 dB for both 925-960 MHz and 1805-1880 MHz ranges.
  • Off Band Attenuation: 3 dB at 880 MHz, >10 dB for frequencies below 750 MHz, 3 dB at 1950 MHz, >10 dB for frequencies above 2050 MHz.
  • Calibration Accuracy: Less than 1 dB at specified frequencies.
  • Operating Conditions: Temperature range of 5-40 °C and humidity range of 10-90% RH, non-condensing.
  • Temperature Error: Less than 0.05 dB/°C for fields greater than 2 V/m.
  • Calibration Traceability: UK NPL or NIST traceable calibration.
  • Physical Dimensions: Size of 9.0x2.25 inches (230x58 mm) and weight of 0.2 lb (100 g).
  • Compatibility: Operates with both RFP-04 and RFP-05 meters.
  • Origin: Designed and made in the USA.
Additional Information: All system parameters are specified for the RFP-05 meter, and specifications may change to reflect design progress.
See more

Catalog excerpts

Probe PI-01V-1

for Smart Fieldmeter® and Smart Fieldmeter® Digital meters Isotropic Dual Band Electric Field Probe PI-01V: 900/1900 MHz, 0.2 - 400 V/m Dual band probe PI-01V was designed for selective RF measurements. The ability to select only specified frequency bands and reject all the rest makes it invaluable tool for cell phone tower certification. Main Parameters∗ • • • • Diode based: 3-Axial isotropic sensor. High Sensitivity: 0.2 V/m. Linearity: +/- 0.5 dB (1-400 V/m). Dynamic range: >66 dB (single range). Selective frequency range: 900-1900 MHz. Calibration frequency ranges: 925-960 MHz and 1805-1880 MHz In band response flatness: +/- 1 dB (925-960 MHz), +/- 1 dB (1805-1880 MHz), Off band attenuation: 3 dB @ 880 MHz, >10 dB @ F<750 MHz, 3 dB @ 1950 MHz, >10 dB @ F>2050 MHz. Calibration accuracy (at specified freq.) <1 dB. Temperature: 5-40 °C, Humidity: RH 10-90%, non-condensing. Temperature error: <0.05 dB/°C (field > 2 V/m). UK NPL or NIST traceable calibration. Small size: LxD: 9.0x2.25 inch, 230x58 mm. Weight: 0.2 lb, 100 g. Operates with both RFP-04 and RFP-05 meters. Designed and made in the USA. All system parameters are given for RFP-05 meter. Specification may be changed to reflect the design progress. EMC Test Design, LLC® P.O. Box 600532, Newton, MA 02460, USA. ww

 Open the catalog to page 1

All EMC Test Design, LLC catalogs and technical brochures

  1. Probe PI-01E

    1  Page

  2. Probe PI-3P

    1  Page

  3. RFP-05M

    2  Pages

  4. SFA-G

    2  Pages

  5. PI-03

    1  Page

  6. PI-07P

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.