1. Catalogs
  2. EMC PARTNER AG
  3. Transient 3000 Conducted Immunity System
video corpo

Transient 3000 Conducted Immunity System

Transient 3000 Conducted Immunity System
1 / 20 PagesView full catalog

Transient 3000 Conducted Immunity System

Product catalog summary
Overview of Phenomena
The Transient 3000 Test System simulates various electromagnetic compatibility (EMC) events, including Electrostatic Discharges (ESD), Electric Fast Transients (EFT), and Voltage Dips/Interrupts. These events can interfere with or damage electronic equipment.
Applicable Standards
The system complies with international standards such as the IEC 61000 series for immunity tests, ITU recommendations for telecommunications, and ANSI standards for surge voltages in low-voltage AC circuits.
Test System Features
The Transient 3000 CE Test System is modular and environmentally friendly, featuring automatic frequency detection, Ethernet and USB ports, and capabilities for ESD up to 16kV and CWG surges up to 4kV/2kA. It supports AC and DC power testing, offering benefits like optimized investment and compatibility with existing accessories.
Generator Specifications
The system operates within a voltage range of 80 to 260V and supports frequencies from 50 to 400Hz. It includes power frequency synchronization, various coupling path selections, and interfaces for Ethernet and RS485 communication, along with atmospheric measurements and power monitoring.
Accessories and Options
The system is compatible with accessories for various testing applications, including three-phase EFT and surge testing, telecom signal lines, and railway electronics testing. It allows on-site configuration changes and supports various power sources.
Software
An internal web server facilitates data presentation and report generation, eliminating the need for proprietary software. Test reports can be customized to include environmental conditions.
EMC PARTNER’s Product Range
EMC PARTNER offers a comprehensive range of EMC testing products, ensuring compatibility and expandability across different models and configurations.
Specifications
1. AC and DC Switching: Sync turn on for AC 0°, DC switching time 1 to 5µs.
2. Power Frequency Tests: DC, 16.7Hz, 50Hz, and 60Hz.
3. Power Harmonic Tests: 1Hz to 150kHz.
4. Sweep Time: 1 decade / 10 to 1000s, Step size 2 to 10%.
5. Short Duration Tests: Up to 300Vrms with accessories.
6. Voltage and Frequency Range: AC voltage 0 to 260Vrms, frequency 48 to 60Hz, DC voltage 0 to 110V.
7. Rated Current: 16A, DIP current variations with external variac.
8. Inrush Current: Greater than 500A.
9. Phase Angle Switching: 0 to 360°.
10. Fast Transient and Surge Tests: Voltage range up to 5.1kV, source impedance 50ohm, pulse front time 5ns, pulse duration 50ns.
11. Immunity Tests: Includes transient test systems, surge combination wave generators, and variation tests.
Procedures
1. Event Duration: Less than 1 period to 29999 dips/ms.
2. Programmable Parameters: Voltage, spike frequency, burst duration, synchronization.
3. Burst Duration and Repetition: 0.01 to 30ms, 1 to 1000ms.
4. Polarity: Positive and Negative.
Standards
1. Compliance with IEC standards such as IEC61000-4-2, IEC61000-4-4, IEC61000-4-5, and others.
2. Options for additional standards compliance.
Accessories and Options
1. Common Mode Tests: DC to 150kHz with various coupling networks.
2. Magnetic Field Tests: Using MF-COIL-HAND and MF-HELMHOLTZ for different field ranges.
3. Three Phase Coupling Networks: For EFT, CWG surge, and ring wave tests.
4. Surge Networks: For data lines and telecom testing.
5. Electrostatic Discharge: ESD discharge module and related accessories.
Software
1. Web Server: Allows access to test reports and service data via PC.
2. GENECS-TRA: Software for remote control and test sequencing.
3. CM-SWEEP: Enables programmable frequency and amplitude variations.
4. Optical Link: Provides EMC isolation for remote control.
General Information
1. EMC PARTNER’s product range includes various test systems and accessories.
2. Contact information for EMC PARTNER headquarters and local representatives.
See more

Catalog excerpts

Transient 3000 Conducted Immunity System-1

Immunity Tests Brief Overview of Phenomena . . Applicable Standards . . . . . . . . . . . . . . . . . . . 3 Test System Overview . . Generator Specifications . . Software . . . . . . . . . . . . . . . . . . . . . . . 18 EMC PARTNER’s Product Range . . . . . . . . . . . . . . 19 Immunity Tests: Transient Test System

 Open the catalog to page 1
Transient 3000 Conducted Immunity System-2

Brief Overview of Phenomena Transient 3000 Test System generates EMC events that can be observed in the low power distribution system, telecommunication or data lines. Transient 3000 Test System replicates the following phenomena: - Electrostatic Discharges (ESD) A person becomes electrostatically charged by walking over an insulating floor surface. The capacity of the body can be charged to several kilovolts and is discharged when contact is made with an electronic unit or system. The discharge is visible as a spark in many cases and can be felt by the person concerned, who receives a „shock“....

 Open the catalog to page 2
Transient 3000 Conducted Immunity System-3

Applicable Standards International Electrotechnical Committee (IEC) IEC 61000-4-2 (Ed2:2008): Testing and measurement techniques - Electrostatic discharge immunity test. IEC 61000-4-4 (Ed3:2012): Testing and measurement techniques - Electrical fast transient / burst immunity test. IEC 61000-4-5 (Ed2:2005): Testing and measurement techniques - Surge immunity test. IEC 61000-4-8 (Ed2:2009): Testing and measurement techniques - Power frequency magnetic field immunity test. IEC 61000-4-9 (Ed1.1:2001): Testing and measurement techniques - Pulse magnetic field immunity test. IEC 61000-4-11 (Ed2:2004):...

 Open the catalog to page 3
Transient 3000 Conducted Immunity System-4

Test System Overview Test System Features Transient 3000 CE Test System has many unique and outstanding features: - Modular design, user configurable - Environmentally friendly - Humidity, pressure and temperature sensor measure lab environment - Automatic frequency detection for mains synchronisation (50 to 400Hz) - Internal web server - Ethernet Port for control, communication and report generation - USB Port: Secure transfer of files, test reports and service data - Common Mode Disturbances DC to 150kHz 30V continuous, 300V short duration - ESD 16kV air / 10kV contact discharge - ESD 16kV...

 Open the catalog to page 4
Transient 3000 Conducted Immunity System-5

Generator Transient 3000 is a technically advanced CE tester. The revolutionary design reinforces EMC PARTNER’s position as a leading technology innovator in the field of EMC tran sient immunity testers. - Environmentally Friendly With less than 50VA power consumption in standby mode and an energy management system that ensures only active circuits are powered, TRA3000 has an extremely low energy footprint. An optimized power consumption also ensures less heat is generated. Coupled to a ventilator with active speed control, noise emissions are drastically reduced. At only 28kg with all modules...

 Open the catalog to page 5
Transient 3000 Conducted Immunity System-6

Vertical Coupling Plate ESD-VCP50 Z:\VK\Verkaufsinstrumente\Brochures\Immunity Tests\Transient Test System\TRA3000\Flowcharts\TRA3000-EFT- Calibration Devices (ESD-Target2, ESD VERI-V) Single Phase AC / DC Power Direct Differential Output Adpater CN-BALUN Three Phase EUT Power Manual Three Phase AC / DC Power CDN2000-06-32 Automatic Three Phase AC / DC Power CDN2000A-06-32 CDN2000A-06-63 CDN-A-3P100-480 F CDN-A-3P100-690 F Calibration Devices (VERI50-EFT, VERI1K-EFT, Adapter EFT-CDN) Immunity Tests: Transient Test System

 Open the catalog to page 6
Transient 3000 Conducted Immunity System-7

Z:\VK\Verkaufsinstrumente\Brochures\Immunity Tests\Transient Test System\TRA3000\Flowcharts\TRA3000-CWG Balanced Telecom Lines CDN-UTP ED8 Railway Application Option NW-TRA-RAIL Single Phase AC / DC Power Direct Coupling Decoupling Modules DN & CN2000-22-5 Direct Injection Probe CN2000TT EUT Manual Three Phase CDN2000-06-32 Three Phase EUT Power Z:\VK\Verkaufsinstrumente\Brochures\Immunity\Transient\TRA3000\Flowcharts\TRA3000-CM-solo.flo Automatic Three Phase CDN2000A-06-32 CDN2000A-06-63 CDN-A-3P100-480 F-S COMMON MODE CDN-A-3P100-690 F-S Common Mode Immunity Tests: Transient Test System

 Open the catalog to page 7
Transient 3000 Conducted Immunity System-8

Single Phase AC / DC Power Direct Three Phase EUT Power Three Phase Interrupt AC / DC Power PFS32 / PFS63 / PFS75 Calibration Device (VERI-DIPS) Single Phase AC Power Direct Three Phase EUT Power Three Phase Interrupt AC / DC Power PFS32 / PFS63 / PFS75 Three Phase DIPS AC Power SRC32 / SRC63 / SRC75 Calibration Device (VERI-DIPS) Immunity Tests: Transient Test System

 Open the catalog to page 8
Transient 3000 Conducted Immunity System-9

Single Phase DC Power Direct Calibration Device (VERI-DIPS) AC Magnetic Field AC MAGNETIC FIELDS Immunity Tests: Transient Test System

 Open the catalog to page 9
Transient 3000 Conducted Immunity System-10

Impulse Magnetic Field IMPULSE MAGNETIC FIELDS Generator Specifications Available Modules TRA3000 BASE Supply voltage range Standby current Internal CDN voltage rating Internal CDN current rating Internal CDN frequency range Power frequency synchronisation Coupling path selection EFT Coupling path selection surge Communication Interface Accessory control interface Memory locations Atmospheric measurement PS3 control EUT Power monitor Surge voltage monitor Surge current monitor Trigger Trigger mode Synchro source Power synchro on/off Power switching before / after test Immunity Tests: Transient...

 Open the catalog to page 10
Transient 3000 Conducted Immunity System-11

EXT-TRA3000 C COMMON Long Duration Voltage Tests Voltage setting range Source Impedance Sync turn on for AC DC switching time Power frequency tests Power harmonic tests Sweep time Step size Short duration tests (with accessories) EXT-TRA3000 D DIPS (Interrupt) AC Voltage range 0 up to 260Vrms Frequency range 48 up to 60Hz Rated current 16A (100% to 0% UT) DIP current 80% 20A (100% to 80% UT & external variac) DIP current 70% 23A (100% to 70% UT & external variac) Switching time 1 up to 5µs DIP modes < 1 period, > 1 period Event duration < 1 period 1 up to 29999 dips Event duration > 1 period...

 Open the catalog to page 11
Transient 3000 Conducted Immunity System-12

EXT-TRA3000 S SURGE Combination Wave Generator (CWG) Voltage Range 0.25 up to 4.1kV Pulse front time at open circuit 1.2µs Pulse duration at open circuit 50µs Source Impedance 2ohm Current range 0.125 up to 2.05kA Pulse front time at short circuit 8µs Pulse duration at short circuit 20µs Pulse repetition up to 20 pulses per minute Programmable parameter ramps voltage, polarity, synchronisation VARIATION 0 up to 260V 6A (100% to 0% UT) Abrupt, Adjust 1 up to 5µs 25 up to 999 periods 1. PS3 can be used for magnetic field testing including 16.7Hz 2. Internal and external variac >500A inrush current...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.