Catalog excerpts
System Automation: Test Place Automation 1 Test Place Automation PS3-Brief Overview . . . . . . . . . . . . . . . . . . . . 2 PS3-Applicable standards . . . . . . . . . . . . . . . . . 2 PS3-Test System Overview . . . . . . . . . . . . . . . . . 4 PS3-Generator Specifi cations . . . . . . . . . . . . . . . . 9 PS3-Software . . . . . . . . . . . . . . . . . . . . . . 9 ICON3000 - Overview . . . . . . . . . . . . . . . . . . 11 Various accessories . . . . . . . . . . . . . . . . . . 12 EMC PARTNER’s Product Range . . . . . . . . . . . . . . 15 System Automation Hardware accessories
Open the catalog to page 12 System Automation: Test Place Automation Test laboratories are confronted by a huge range of electrical and electronic products with vastly differing power requirements. Frequency and voltage combinations not available from the mains power outlet. Test samples that cause inadequate supplies to cave-in under load. PS3, from EMC PARTNER, solves these problems instantly. Convert the mains wall plug into a custom AC and DC power supply, changeable at the push of a button to any pre-selected frequency or voltage combination. PS3 is fl exible enough to perform EMC immunity tests for CE mark...
Open the catalog to page 2System Automation: Test Place Automation 3 PS3 with TRA2000 and MF1000-x IEC 61000-4-9: (A2:2000).Testing and measurement techniques - Section 9: Pulse magnetic fi eld immunity test PS3 with MF1000-x IEC 61000-4-8: (A2:2000).Testing and measurement techniques - Section 8: Power frequency magnetic fi eld immunity test. PS3 with avionics test system Radio Technical Commission for Aeronautics RTCA DO-160D (change No.3 December 5, 2002) -Environmental Conditions and Test Procedure for Airborne Equipment. -Sections 17, 19, 22 European Organisation for Civil Aviation Equipment EUROCAE / ED-84...
Open the catalog to page 34 System Automation: Test Place Automation Test System Features - Preset Voltage/Frequency combinations - Flexible programming capability - Rapid switching between voltages and frequencies. - DC output 10 to 350V - AC up to 400Hz - 3000W power at 230V User Benefi ts - Preset outputs – enable a quick start without the concern that the last voltage settings may be incorrect and damage equipment. - User programmable output selection – one output selector is user programmable with any Voltage / Frequency combination. - User software – extends PS3 from a power source to a fully programmable...
Open the catalog to page 48 System Automation: Test Place Automation PS3 DO160 Single Stroke and Multiple Stroke EUT Public power supply 115V 60Hz or 230V 50Hz PS3 Immunity tests: DO 160 S22 Single and Multiple Stroke 115V 400Hz MIG0600MS SYNC-ADAPTER Coupling Pulses PS3 Spikes EUT Public power supply 115V 60Hz or 230V 50Hz PS3 Immunity tests: DO 160 S17 Spikes on power supply NATO Fast/Slow MIL461C 115V 400Hz MIG2000-6 SYNC-ADAPTER PLUG IN's Spikes Avionic Test System MIG2000-6
Open the catalog to page 8System Automation: Test Place Automation 9 PS3-Generator Specifi cations PS3 Specififi cations Input range 100V up to 240V, 47 to 63Hz Maximum Current 20A2) rms Power factor 0.98 a.c. IN = 100V 0.95 a.c. IN = 200V Public power supply fuse Safety fuse 20 AT Over current trip 20A type C Power 3000W 3) Output supplies pre-programmed 230V/50Hz; 230V/16.7Hz, 115V/60Hz; 115V/400Hz Maximum current 16A3) rms Output frequency accuracy < 0.3% for 16.7, 50, 60Hz < 0.6% for 400Hz Output voltage accuracy a.c. 2% Output voltage accuracy d.c ±1.5V from ±10 to 49V, 1A load ±3V from 50 to 100V, 0.5A load...
Open the catalog to page 910 System Automation: Test Place Automation AC/DC program AC Voltage variation program Sequences of IEC 61000-4-28 In general, electrical and electronic equipment are not susceptible to minor variations of the power frequency. Testing according to this standard should be limited to products which are assessed to be susceptible to power frequency variations by virtue of design, environment or failure consequences. The immunity test levels required for a specififi c electromagnetic environment together with the performance criteria are indicated in the product, product family or generic...
Open the catalog to page 10System Automation: Test Place Automation 11 ICON3000 - Overview ICON3000 Description ICON3000 control and peak measuring system 19” plug-in 4 UH for use with Marx impulse generators, current generators and high voltage d.c. supplies. With rear plate, connector sockets and special interface. Applications - Control of Insulation withstand test generators After the design and the production of an equipment, tests must be carried out to verify the insulation voltage withstand capability. - Control of energy impulse test generators (current generators) - Control of special impulse test...
Open the catalog to page 1112 System Automation: Test Place Automation Various accessories TC-MIG24 Test cabinet made of acrylic glass, for EUT with max. dimensions 30x20x20cm. Insulation withstand 1.2/50ìs up to max. 36kV. With interlock safety switch and warning lamps green/red. Usable with all generators with output on top. TC-MIG24 TC-MIG24 HL TC-MIG24 HL Test cabinet for heavy loads, made of acrylic glass, for EUT with max. dimensions 30x20x20cm. Insulation withstand 1.2/50ìs up to max. 36kV. With interlock safety switch and warning lamps green/red. Can be stood next to generator. COVER BOX LARGE COVER BOX LARGE...
Open the catalog to page 12System Automation: Test Place Automation 13 CN-MIG18 SHOE CN-MIG18 SHOE Two test pistols, cable length 1.5m with cable shoes. The test pistols can be used together with MIG systems with TC-MIG24 for insulation tests. Can not be used for CWG or current generators. CN-MIG18 AMP CN-MIG18 AMP Two test pistols for conducted tests. Cable length 1m with AMP plugs. The test pistols can be used together with MIG systems equipped with AMP plug outputs. CN-MIG24 CN-MIG24 EUT connection box with two test pistols, interlock and warning lamps green/red. Usable with MIG systems with output on top up to...
Open the catalog to page 1314 System Automation: Test Place Automation RS232CB Serial connection of two generators e.g. MIG and HAR. RS232CB USB-RS232 ADAPTER RS232 / USB adapter for remote control of EMCP generators from PC with USB. USB-RS232 ADAPTER OPTICAL LINK Serial, optical connection between PC and generator, length 20 m. Incl. 1 Gender Changer f.-f. 25pole. OPTICAL LINK AUX-SYNC-ADAPTER External synchronisation of generators with the AUX-SYNC-ADAPTER for 50/60Hz power supplies e.g. MIG1203CWG AUX-SYNC-APDAPTER SYNC-ADAPTER External synchronisation of generators with the SYNC-ADAPTER galvanically decoupled...
Open the catalog to page 14All EMC PARTNER AG catalogs and technical brochures
-
Conducted Immunity Testing
64 Pages
-
Component Testing
60 Pages
-
Service & Calibration
12 Pages
-
Military & Aerospace Testing
20 Pages
-
Electrostatic Discharge Testing
20 Pages
-
IMU3000 Test System
20 Pages
-
Oscillatory Test System
16 Pages
-
Transient 3000 Test System
20 Pages
-
Avionic Test System
20 Pages
-
Software Accessories
16 Pages
-
Electricity Meter Test System
16 Pages
-
Hardware Test Automation
12 Pages
-
Indirect Lightning Test System
20 Pages
-
ESD Test system
16 Pages
-
Telecom Test System
16 Pages
-
Protection Device Test Equipment
20 Pages
-
Low Frequency Measuring System
12 Pages
-
e-test_place_automation
12 Pages
-
Insulation Test System
12 Pages
-
Avionics Test System
20 Pages
-
Combination Wave Test System
16 Pages
-
Oscillatory Wave Test System
16 Pages
-
Capacitor Test Systems
12 Pages
-
Military Test Systems
12 Pages