Product catalog summary
Overview of Phenomena
Damped oscillatory waves are produced during the operation of high voltage (HV) and medium voltage (MV) power transmission stations. These waves are classified into 'Slow Waves' (up to 1MHz) and 'Fast Waves' (up to 30MHz), based on the insulation type used in switches. The document examines the effects of these waves on power supply communication networks and emphasizes the necessity for testing equipment to simulate these impacts.
Applicable Standards
The document cites several standards for testing and measurement techniques, including IEC 61000-4-18 for damped oscillatory wave immunity tests, IEC 60255-22-1 for electrical disturbance tests, and ANSI C37.90.1 for surge withstand capabilities.
Test System Overview
The test system is capable of generating slow oscillatory waves at 100kHz and 1MHz with amplitudes up to 3000V, and fast oscillatory waves at 3MHz, 10MHz, and 30MHz with amplitudes up to 4000V. It is designed for high automation, featuring automatic coupling path selection and electronic polarity change.
Generator Specifications
The document details several generator models, each with specific capabilities for generating damped oscillatory waves and magnetic fields. Key specifications include oscillation frequencies, voltage ranges, source impedance, and pulse rise times. Antennas are also described for magnetic field testing.
Accessories and Options
The system can be expanded with external three-phase couplers for enhanced testing capabilities. These couplers are compatible with various standards and can be controlled via software or manually.
Specifications and Equipment
The document outlines specifications for various testing equipment used in electromagnetic compatibility (EMC) testing, including line voltages (L to N=280V and L to L=415V or 480V) and line current (25A per phase). Equipment such as CDN2000-06-25 and CDN3000A-06-25 are mentioned for testing with oscillatory waves, surge, EFT/burst, and ring wave impulses. The use of MF1000 coil antennas for generating magnetic fields is also specified.
Testing Standards and Procedures
The document references several IEC standards applicable to EMC testing, including IEC 61000-4-8, IEC 61000-4-9, and IEC 61000-4-10. It describes the use of MIG damped oscillatory wave testers and the extension of slow wave generators to include fast wave impulses at frequencies of 3, 10, and 30MHz.
Software and Automation
Software options for remote control of testing equipment are discussed, including GENECS-MIG and TEMA Software, which facilitate control and test report generation. The document highlights the importance of system automation and the availability of accessories to enhance test systems.
Product Range and Applications
EMC PARTNER offers a wide range of impulse test equipment for various applications, including aircraft, military, and telecom. The document lists equipment for component tests and emission measurements, adhering to standards like IEC/EN 61000-3-2 and 61000-3-3.
Service and Support
EMC PARTNER provides accredited calibration and repair services, supported by a quality management system. Contact information for EMC PARTNER's headquarters in Switzerland and local representatives is provided for further assistance.
See more

Catalog excerpts

Oscillatory Test System-1

Immunity Tests Oscillatory Wave Test System Brief Overview of Phenomena . . Applicable Standards . . . . . . . . . . . . . . . . . . . 3 Test System Overview . . Generator Specifications . . Software . . . . . . . . . . . . . . . . . . . . . . . 14 EMC PARTNER’s Product Range . . . . . . . . . . . . . . 15 Immunity Tests: Oscillatory Wave Test System

 Open the catalog to page 1
Oscillatory Test System-2

Brief Overview of Phenomena Repetitive damped oscillatory waves are phenomena associated with the opening and closing of high voltage (HV) busbars in high voltage (HV) and medium voltage (MV) power transmission stations. The physical environment influences the fundamental oscillation frequency and repetition of the impulses. The most common type of switch used in power distribution is an air insulated type which has been measured as generating damped oscillatory impulses up to 1MHz with a repetition rate up to 400Hz. Damped oscillatory impulses up to 1MHz are termed “Slow Waves”. The modern trend...

 Open the catalog to page 2
Oscillatory Test System-3

Applicable Standards International Electrotechnical Committee (IEC) IEC 61000-4-18 Ed2 (2009): Electromagnetic compatibility (EMC) - Testing and measurement techniques - Damped oscillatory wave immunity test. IEC60255-22-1 Ed3 (2007): Measuring relays and protection equipment - Electrical disturbance tests - 1 MHz burst immunity tests. IEC60947-1 Ed5 (2007): Low-voltage switchgear and control gear - General rules. IEC 61000-6-6 Ed1 (2003): Electromagnetic compatibility (EMC) - Generic standards - HEMP immunity for indoor equipment. IEC61000-4-10 Ed1.1 (2001): Electromagnetic compatibility (EMC)...

 Open the catalog to page 3
Oscillatory Test System-4

Test System Overview Test System Feature - Slow oscillatory waves 100kHz, 1MHz - Pulse repetition up to 400Hz for slow waves - Amplitude up to 3000V - Output impedance 200 ohm - Fast oscillatory waves 3MHz, 10MHz, 30MHz - Pulse repetition 5kHz - Burst duration 1ms to 50s - Burst repetition 20ms to 999s - Amplitude up to 4000V - Output impedance 50 ohm - Automatic coupling path selection - Impulse parameters defined at CDN output - Parameter ramp feature - Electronic polarity change - Semiconductor switches - Compact design - High degree of automation without software - 2 year warranty User Benefits...

 Open the catalog to page 4
Oscillatory Test System-5

- MIG-OS-OS1 The “classic” damped oscillatory wave generator for IEC, EN and ANSI applications. The slow waves are available through either balanced differential or grounded outputs. The 100kHz and 1MHz waveforms can be programmed up to 3000V. This generator is ideal for applications requiring only the slow waves. - MIG0603OSI A combination of slow wave generator up to 3000V, combination wave generator up to 6000V/3000A and 1.2/50µs voltage impulse up to 6000V with 0.5J energy content. All impulses can be used for IEC, EN and ANSI applications. - MIG-OS-OM A combination of the “classic” damped...

 Open the catalog to page 5
Oscillatory Test System-6

Flowcharts Slow Damped Oscillatory Waves TEMA TEST MANAGER customized solution Z:\VK\Verkaufsinstrumente\Brochures\Immunity\Oscillatory\MIG-OS-OSx Fast.flo Fast Damped Oscillatory Waves EUT Fast Damped Oscillatory Waves TEMA TEST MANAGER customized solution Immunity Tests: Oscillatory Wave Test System

 Open the catalog to page 6
Oscillatory Test System-7

Magnetic Field Damped Oscillatory Wave Magnetic Field TEMA TEST MANAGER customized solution MIG-OS-OM MIG-OS-MF Z:\VK\Verkaufsinstrumente\Brochures\Immunity\Oscillatory\MIG-OS-OSx Slow Data.flo Slow Damped Oscillatory Waves Data EUT Slow Damped Oscillatory Waves for Signal and Control Ports TEMA TEST MANAGER customized solution Signal Lines Immunity Tests: Oscillatory Wave Test System

 Open the catalog to page 7
Oscillatory Test System-8

Fast Damped Oscillatory Waves for Signal and Control Ports TEMA TEST MANAGER customized solution Signal Lines Generator Specifications MIG-OS-OS1 Damped Oscillatory Waves Oscillation frequency Voltage range Source impedance Voltage increment Damping rate Pulse rise time Burst repetition at 100kHz Burst repetition at 1MHz Polarity 100kHz & 1MHz 0.2 up to 3kV 200 ohms 1V steps 50% between 3rd and 6th periods 75ns up to 50Hz up to 500Hz Positive, negative, alternating MIG0603OSI Damped Oscillatory Waves Oscillation frequency Voltage range Source impedance Voltage increment Damping rate Pulse rise...

 Open the catalog to page 8
Oscillatory Test System-9

Combination Wave 1.2/50µs (8/20µs) Voltage range Voltage increment Short circuit current Source impedance Energy at 6kV Pulse interval Polarity Programmable parameter ramps 0.5 up to 6kV 1V steps 0.25 up to 3000A 2 ohms 220J 8 seconds at max. voltage Positive, negative, alternating Voltage, synchronisation, polarity Impulse Voltage 1.2/50µs (0.5J) Voltage range Source impedance Voltage increment Energy Pulse interval Polarity Programmable parameter ramps 0.25 up to 6.3kV 500 ohms 1V steps 0.5J 8 seconds at max. voltage Positive, negative, alternating Voltage, synchronisation, polarity MIG-OS-OM...

 Open the catalog to page 9
Oscillatory Test System-10

MIG0603OMI Damped Oscillatory Waves (DOW) Oscillation frequency Voltage range Source impedance Voltage increment Damping rate Pulse rise time Burst repetition at 100kHz Burst repetition at 1MHz Polarity 100kHz & 1MHz 0.2 up to 3kV 200 ohms 1V steps 50% between 3rd and 6th periods 75ns up to 50Hz up to 500Hz Positive, negative, alternating Damped Oscillatory Waves Magnetic Field with MF1000-1 Oscillation frequency Antenna dimension Current range with MF1000-2 (100kHz) Oscillation frequency Antenna dimension Current range with MF1000-2 (1MHz) Oscillation frequency Antenna dimension Current range...

 Open the catalog to page 10
Oscillatory Test System-11

Voltage range Voltage increment Short circuit current Source impedance Pulse interval _ Programmable parameter ramps Positive, negative, alternating Voltage, synchronisation, polarity Waveform at no load No load = R > 100Ohm Time to half value 50us Adjustable voltage range 500V - 6000V Test Energy Generator Impulse Voltage voltage Impedance capacitor Waveform Damped Oscillatory Waves Magnetic Field Oscillation frequency Antenna dimension Current range Oscillation frequency Antenna dimension Current range Immunity Tests: Oscillatory Wave Test Syst

 Open the catalog to page 11
Oscillatory Test System-12

Accessories and Options External Three Phase Couplers Damped oscillatory wave testers can be extended with automatic or manual threephase coupling networks. The CDN2000-06-25 and CDN3000A-06-25 can also be used for EFT, CWG surge and ring wave. Coupling path selection is either from the MIG firmware, from GENECS and TEMA software or manually on the CDN front panel (manual version only). The coupling networks fulfill the requirements laid down in the IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-12 (ring wave), IEC61000-4-18, ANSI C37.90 and ANSI C62.41 standards. CDN2000-06-25 Manual three phase...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.