Catalog excerpts
Immunity Tests IMU3000 Overview . . . . . . . . . . . . . . . . . . . . 3 Features & Benefits . . Application Options . . Technical Specifications . . EMC PARTNER’s Product Range . . Immunity Tests: IMU3000 Test System
Open the catalog to page 1RINGWAVE R/R6 extension SURGE S/S6 extension COMMON MODE C extension EPOS Module EMC PARTNER Operating System (EPOS) is the heart of IMU3000. The user interface is a modern 7” touch panel display with colour graphics that make parameter entry and system programming an experience that is second to non. Circuits indicated with the Button need a HV Module for correct function. (See Table on page 11) Immunity Tests: IMU3000 Test System
Open the catalog to page 2Electrostatic Discharges (ESD) Connected to the IMU3000 front panel on the RS485 data bus, EXT-TRA3000 E gives 16kV Air discharge and 10kV Contact discharge. The additional “Firing” mode enables fault finding using continuous discharges. Electric Fast Transient / Burst (EFT) Plug-in for the IMU3000 mainframe. EXT-IMU3000 F5 / F6 generates fully compliant impulses up to 5kV / 6kV, meeting and exceeding IEC and EN basic standard requirements. HV output for use with Capacitive coupling clamp and 3-Phase CDNs S extension Combination Wave GeneratorPN: 106536 / 8kV PN: 105679 6kV /Surge (CWG)...
Open the catalog to page 3Easy Programming 7" Colour touch panel Rotary knob for navigation and data entry EPOS (EMC PARTNER Operating System) a new concept in graphical user interface Service Friendly User replaceable extensions Built in self test routines USB port to access service data Highest Test Levels CWG Surge, 100kHz Ringwave, 10/700us Telecom Compatible with existing Transient accessories. Immunity Tests: IMU3000 Test System
Open the catalog to page 4Your aim is to perform testing Minimum learning time Easy to follow user interface :ATOR DETAILS Operator: Anybody nent Under Test) DETAILS Serial Number: Motor drive with PWM control Second production batch Tiqger auto Altern Aig PbtHiiy : starting pmlne Change Ftamp wbe alter 5 pUae{B] Save Time Test setup fast and error free. Get test report information as HTML file Start with a single function tester. Customize to your requirements Keep Testing Maximize system up time Calibrated extensions exchanged on site No disruption to the testing program Only Need One Tester Expandable to include...
Open the catalog to page 5Application Options 3-Phase EFT, SURGE and Ringwave Multi function Coupling Decoupling Networks provide a single EUT connection point for multiple tests. EFT, Surge and Ringwave can all be injected through the same CDN to save setup time. External CDNs either manually operated or automated via the RS485 bus on IMU3000. IMU3000 menu structure updated if an automated CDN is connected. Range of products from 32A up to 200A per phase. 3-Phase AC Dips and Interrupts Units for Interrupt and/or dip testing. Fully automatically controlled via the RS485 bus on IMU3000. Phase angle and amplitude...
Open the catalog to page 6Standards International Electrotechnical Committee (IEC) IEC 61000-4-2 : Testing and measurement techniques - Electrostatic discharge immunity test. IEC 61000-4-4 : Testing and measurement techniques - Electrical fast transient / burst immunity test. IEC 61000-4-5: Testing and measurement techniques - Surge immunity test. IEC 61000-4-8: Testing and measurement techniques - Power frequency magnetic field immunity test. IEC 61000-4-9: Testing and measurement techniques - Pulse magnetic field immunity test. IEC 61000-4-11: Testing and measurement techniques - Voltage dips, short interruptions...
Open the catalog to page 7Technical Specifications Electro Static Discharge EXT-TRA3000 E (ESD) Air discharge Contact discharge Continuous Firing mode Voltage increment resolution Contact discharge repetition interval Discharge detection Discharge counter Discharge polarity Holding time Programmable parameter ramps Discharge trigger 0.5 up to 16kV 0.5 up to 10kV 0.5 up to 16kV 1 volt steps 0.05 to 30s every pulse or real discharges only 1 to 29999 Positive / Negative / Alternating 5s voltage, polarity manual or automatic Electric Fast Transient (Burst) EXT-IMU3000 F5 (EFT 5kV) Voltage range Voltage amplitude into...
Open the catalog to page 8Technical Specifications COMMON SURGE (CWG) SPECIFICATIONS Source impedance Serial resistance common mode Pulse front time at open circuit Pulse duration at open circuit Pulse front time at short circuit Pulse duration at short circuit Pulse repetition Pulse repetition at maximum voltage Polarity Programmable parameter ramps Synchronisation on power line frequencies 2ohm 10ohm 1.2µs 50µs 8µs 20µs up to 60 pulses per minute 6 pulses per minute Positive / Negative / Alternating voltage, synchronisation, polarity Yes EXT-IMU3000 T (TELECOM 8kV) Voltage range Current range EXT-IMU3000 T6...
Open the catalog to page 9Technical Specifications DIPS, Interrupts, Variations EXT-TRA3000 D (AC Dips) Voltage range Frequency range with variac Nominal current Interruption time Amplitude interrupt with internal variac Phase angle to turn on and off Voltage variation with internal variac Interrupt less than 1 period Interrupt more than 1 period Programmable parameter ramps Rise and fall time at 100ohm load 0 up to 250V 48 up to 60Hz 16A 50µs up to 30s 0 up to 100% max. 5A 0° up to 360° 0 up to 110% max. 5A Input by phase angle Input in milliseconds voltage, synchronisation, interrupt 1 up to 5µs EXT-TRA3000 D (DC...
Open the catalog to page 10Technical Specifications Mainframe Specifications IMU3000 Control features User Interface Operating System Communication Interface Accessory control interface Atmospheric measurement BNC monitor ports Trigger mode Synchro source Synchro on / off 7” Colour touch panel EMC PARTNER (EPOS) Ethernet RS485 Temperature, humidity, pressure EUT plus IMPULSE voltage & current Auto, manual, external EUT power, Impulse out, External 0° up to 360° IMU3000 Coupling Decoupling Network Maximum AC voltage Maximum DC voltage Maximum EUT current Frequency range Power frequency synchro Coupling EFT Coupling...
Open the catalog to page 11Accessories and Options COMMON MODE TESTS DC to 150kHz EXT-TRA3000 C-SHORT Extends IMU4000 C with 1s short test. DC, 16.7Hz, 50Hz and 60Hz up to 300V. External box with 50 ohm output. Programming and control from IMU4000 front panel. Coupling network for common mode testing DC to 150kHz. Coupling onto DC, AC single and three phase supplies. CN16T T coupling network for common mode testing DC to 150kHz. Coupling onto telecom lines. One telecom pair per CN16T. Coupling network for 2 port common mode testing in accordance with IEC 60255-22-7. R = 220 ohm and C = 0.47uF. CN16-22-7 D Coupling...
Open the catalog to page 12All EMC PARTNER AG catalogs and technical brochures
-
Conducted Immunity Testing
64 Pages
-
Component Testing
60 Pages
-
Service & Calibration
12 Pages
-
Military & Aerospace Testing
20 Pages
-
Electrostatic Discharge Testing
20 Pages
-
Oscillatory Test System
16 Pages
-
Transient 3000 Test System
20 Pages
-
Avionic Test System
20 Pages
-
Software Accessories
16 Pages
-
Electricity Meter Test System
16 Pages
-
Hardware Test Automation
12 Pages
-
Indirect Lightning Test System
20 Pages
-
ESD Test system
16 Pages
-
Telecom Test System
16 Pages
-
Protection Device Test Equipment
20 Pages
-
Low Frequency Measuring System
12 Pages
-
e-test_place_automation
12 Pages
-
Insulation Test System
12 Pages
-
Avionics Test System
20 Pages
-
Combination Wave Test System
16 Pages
-
Oscillatory Wave Test System
16 Pages
-
Capacitor Test Systems
12 Pages
-
Military Test Systems
12 Pages