Electrostatic Discharge Testing
20Pages

{{requestButtons}}

Catalog excerpts

Electrostatic Discharge Testing - 1

ESD3000 - MODULAR HANDHELD TESTER Electrostatic Discharge Testing

Open the catalog to page 1
Electrostatic Discharge Testing - 2

This document has been optimized for electronic media Smart navigation through technical specifications. Click the green links. Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management system. This is the foundation for an ISO 17025 accreditation verified by the Swiss Calibration Service (SCS). SCS No. 146 is the accreditation number of EMC PARTNER AG. Locally accredited but recognized worldwide through affiliation with the ILAC organisation

Open the catalog to page 2
Electrostatic Discharge Testing - 3

POWER AT YOUR FINGER TIPS WESHALB BRAUCHT ES EINEN STYLE GUIDE ? Electrostatic Discharge (ESD) is the most common test procedure applied to any electronic or electrical equipment. Used extensively to test: ›› ›› ›› ›› ›› ›› ›› ›› ›› Commercial products Industrial systems Military electronics Automotive electronics Fuses and detonators Railway electronics Avionic equipment qualification Telecom equipment Electronic components The easily changeable and fully calibrated discharge networks, quickly adapt ESD3000 to the requirements of any new appli

Open the catalog to page 3
Electrostatic Discharge Testing - 4

ESD3000 is designed with the user in mind. The modular design allows configuration according to customer wishes, addition of more networks when adding applications and easy extension from 16kV to 30kV using the same generator. Automatic network recognition means ESD3000 is always ready. Included Rechargable Long-life batteries Up to 3 test tips (Sharp, Round, Corona) Charger & Firmware update cable Handy, robust carrying case

Open the catalog to page 4
Electrostatic Discharge Testing - 5

AVAILABLE MODULES Commercial & Industrial IEC 61000-4-2 Component Test IEC 61340-3-1 / JEDEC 22-A114 / MIL-STD-750D Automotive ISO 10605 / SAEJSSI-IS/FORD AB/AC /GMW 3097

Open the catalog to page 5
Electrostatic Discharge Testing - 6

UNIQUE FEATURES The original 30kV battery powered generator with a unique system of changeable modules. Flexibility and power combined. AA battery powered Electronic polarity change Long life standard battery. Up to 8 hours on full battery charge. Readily available in any store. Single key press switches polarity before and during the test. Extend testing capability Add calibrated modules to maintain the system value. Unique modules and accessories for special applications. Compact solution Ergonomic hand held tester without additional base unit. Program directly on generator.

Open the catalog to page 6
Electrostatic Discharge Testing - 7

Tradition meets Technology Over 20 years devoted to combining latest technologies into the best products. + 100% Swiss made products

Open the catalog to page 7
Electrostatic Discharge Testing - 8

Technical Specifications

Open the catalog to page 8
Electrostatic Discharge Testing - 9

* DN1 as alternative to DM1. Standard requires only 15 kV.

Open the catalog to page 9
Electrostatic Discharge Testing - 11

1.1. TECHNICAL SPECIFICATIONS ESD3000 Mainframe To be used with modules Construction Control Maximum voltage Voltage steps Discharge polarity Discharge modes Discharge frequency CD Discharge frequency AD Counter Discharge detection Holding time Trigger Ramps Reporting with TEMA Dimensions Weight mainframe Weight equipped Power supply Included Requires all modules from this document are compatible fully portable, no additional basic unit LCD and 6 menu buttons, 1 trigger button 16 kV or 30 kV, depending on modules chosen 100 V - test positive, negative, alternating contact discharge (CD) and...

Open the catalog to page 11
Electrostatic Discharge Testing - 12

Storage capacitor 150 pF according to IEC61000-4-2 Discharge resistor 330 Q according to IEC61000-4-2 Current rise time into 2 O 0.8 ± 25 % First I peak into 2 O CD 7.5 A @ 2 kV - 37.5 A @ 10 kV (± 15 %) Current rise time into 2 O < 10 ns @ 0.2 - 8 kV I peak into 2 O (CD) 2.66 A @ 4 kV, 3.33 A @ 5 kV Storage capacitor 100 pF according to IEC61000-4-2 Discharge resistor 1500 Q according to IEC61000-4-2 Current rise time into 2 O 2 - 10 ns @ 0.25 - 8 kV

Open the catalog to page 12
Electrostatic Discharge Testing - 13

30 KV These extensions need the module ESD3000RM32 Storage capacitor 150 pF according to IEC61000-4-2 Discharge resistor 330 Q according to IEC61000-4-2 Current rise time into 2 O 0.8 ± 25 % First I peak into 2 O CD 7.5 A @ 2 kV - 112.5 A @ 30 kV Included in ESD3000RM32 Detachable module for faster tr (<700ps) Optional ESD-TARGET2 DN, ESD-HCP-AUTO Storage capacitor 330 pF according to IEC61000-4-2 Discharge resistor 2000 Q according to IEC61000-4-2 Current rise time into 2 O 0.7 - 1 ns First I peak into 2 O CD 7.5 A @ 2 kV - 112.5 A @ 30 kV (- 0 / + 30 %) Storage capacitor 150 pF according...

Open the catalog to page 13
Electrostatic Discharge Testing - 14

I rise time into 2 Q CD 0.7 - 1 ns Optional ESD3000 SAFETY-S, DM-EXT, TC-MIG24ED I rise time into 2 Q CD 0.7 - 1 ns Optional ESD3000 SAFETY-S, DM-EXT, TC-MIG24ED Storage capacitor 330 pF according to IEC61000-4-2 Discharge resistor 330 Q according to IEC61000-4-2 Current rise time into 2 Q 0.7 - 1 ns RC time constant 300 ± 130

Open the catalog to page 14
Electrostatic Discharge Testing - 15

Power consumption ON < 20 VA, standby < 5 VA Shipping weight 2.4 kg plus selected modules Carrying case dimensions 46 x 41 x 17 cm Included in delivery User manual with conformity declaration Calibration certificate factory calibration for selected modules

Open the catalog to page 15
Electrostatic Discharge Testing - 16

2.1. TECHNICAL SPECIFICATIONS EARTH CABLE Application connection of HCP or VCP to ground plane Connectors 2 x banana plugs ESD-VCP50 Application indirect ESD application as per IEC 61000-4-2 Spacer in between 10 cm wooden spacer Application points one on each side Included 2 m earth cable (with 2 x 470 kQ) Application current target for calibration of ESD generator Current range 0 - 50 A standard, could be extended Transfer function 0.2 V / 1 A with 20 dB Weight 398 g including attenuator Fixing 8 x M3 screws, included in delivery Included 20 dB att., 50 Q coax. cable (1 m) with SMA out...

Open the catalog to page 16
Electrostatic Discharge Testing - 17

Application target for ESD DC voltage measurement Input voltage range 0 - 32 kV Output voltage range 0 - 1.6 V in 10MO or 1MO Dimensions 17 cm height, 5.5 cm diameter Included earth conductor, BCN adapter, BNC termination ESD-STAND Ed2 Application stand for supporting ESD gun, fixed point test Included cable holder for calibration ESD-HCP-AUTO Application coupling plane as per ISO 10605 annex F Test level 8 - 20 kV, as per standard Included EARTH CABLE ESD3000DM-EXT Application 1 m extension cable for ESD3000 modules Weight 0.5 kg including accessories Can be used with DN modules...

Open the catalog to page 17

All EMC PARTNER AG catalogs and technical brochures