Conducted Immunity Testing
64Pages

{{requestButtons}}

Catalog excerpts

Conducted Immunity Testing - 1

COMPLETE TEST SOLUTIONS FOR Conducted Immunity Testing

Open the catalog to page 1
Conducted Immunity Testing - 2

This document has been optimized for electronic media Smart navigation through technical specifications. Click the green links. Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management system. This is the foundation for an ISO 17025 accreditation verified by the Swiss Calibration Service (SCS). SCS No. 146 is the accreditation number of EMC PARTNER AG. Locally accredited but recognized worldwide through affiliation with the ILAC organisation

Open the catalog to page 2
Conducted Immunity Testing - 3

THE CONDUCTED IMMUNITY TEST SYSTEM MANY CHOICES ONE SOLUTION Basic and product standards require a mix of conducted immunity EMC tests. Required test types can include: › › › › › › › Electric Fast Transient (EFT) Surge (CWG, Ring wave, Telecom) Damped Oscillatory Wave (DOW) AC / DC Dips & Interrupts AC / Impulse / DOW magnetic field Common Mode Differential Mode The ideal is a flexible test equipment that combines any or all of these requirements into one single s

Open the catalog to page 3
Conducted Immunity Testing - 4

CUSTOM IS STANDARD IMU and DOW generators are designed with the user in mind. A modular architecture allows configuration of test circuits to meet any requirement. A solution that can easily be extended with more modules when additional tests are needed. IMU-MGE DOW series DOW Mainframe Unit IMU series IMU Mainframe Unit Available Modules Surge / CWG 4kV / 5 kV / 6kV / 8kV Ring Wave 6kV / 8kV Telecom 6kV / 8kV EFT 4kV / 5kV / 6kV / 7kV / 8kV Common Mode 35V / 330V AC & DC Interrupts 16A / 32A / 75A AC DIPS & Variation 16A Differential Mode voltage / current ESD 16kV WHY MODULARITY ? You get...

Open the catalog to page 4
Conducted Immunity Testing - 5

AVAILABLE TESTS IMU Series ESD Electrostatic Discharges Electric Fast Transient / Burst (EFT) According to IEC/EN 61000-4-4 Combination Wave /Surge (CWG) According to IEC/EN 61000-4-5, ANSI C62.41 Telecom Impulse (10/700) According to IEC/EN 61000-4-5, ITU-T K.44 Ring Wave 100kHz (Ring) According to IEC/EN 61000-4-12, ANSI C62.41 Common Mode (CM) According to IEC/EN 61000-4-16 Differential Mode (DM) According to IEC/EN 61000-4-19 AC & DC Dips, Variations and Interruptions According to IEC/EN 61000-4-11 /-29 /-34 Magnetic Field / Pulse According to IEC/EN 61000-4-8 / -9 SLOW Damped...

Open the catalog to page 5
Conducted Immunity Testing - 6

Enhanced safety is standard Red/Yellow Emergency Stop button on front panel of generator can be complemented with remote option. Add warning lamps and a test cabinet for enhanced test place safety. UNIQUE FEATURES Leading technology - New designs take advantage of latest innovations. Test routines Link together many different test types into one sequence. Generate test reports via USB interface or built in webserver as csv, html and pdf formats. Online updates free of charge Extend testing capability Software download from internet directly into the instrument. Test reporting Hardware...

Open the catalog to page 6
Conducted Immunity Testing - 7

EPOS - BEYOND BETTER EMC PARTNER Operating System (EPOS) is an independent software with free-of-charge updates for lifetime. EPOS is based on a full colour graphic interface and easy to follow onscreen graphics. Pop-up help gives information when needed, directly during the setting process. EPOS is full of features found only in top of the range instrumentation. Test setup libraries Simple touch screen navigation Pre-programmed tests for all basic and generic standards included. Save time with the latest in intuitive menu structures. Power management We speak your language Active monitor...

Open the catalog to page 7
Conducted Immunity Testing - 8

TEMA3000 SOFTWARE SUITE The best solution for professional EMC Test Labs enables comfortable test setups, easy parameter changes, customizable test reports and DSO integration. Want to know more? Further information and demo version available on the website Customizable test reports Manage tests and sequences Customize & edit your protocols Export to multiple file formats Integrate DSO measurements Predefined test setups Save and load own tests and sequences Productive workflow Smart connectivity Minimum learning time Integrated assistant function Transfer tests / reports to PC Integrated...

Open the catalog to page 8
Conducted Immunity Testing - 9

Technical Specifications IMU-MGS | IMU-MGE | DOW-CG1 | CDNs | Accessories

Open the catalog to page 9
Conducted Immunity Testing - 10

Supply Lines CDNs for burst, Surge and Ring wave 4 kV / 6 kV line CDN-DOW-DATA-LF CDN-DOW-

Open the catalog to page 10
Conducted Immunity Testing - 11

EARTH CABLE ADAPTER EFT-CDN EXT-IMU C-SHORT EMERGENCY STOP WARNING LAMP

Open the catalog to page 11
Conducted Immunity Testing - 12

GENERATORS IMU-MGS IMU-MGS Mainframe EUT power input 1 (CDN) EUT power input 2 (CDN) Internal CDN freq. range Power freq. synchr. Coupling Burst Coupling Surge max. AC/DC 300V, 16A (fused 16A) with P module max. AC/DC 300V, 16A (not fused) with P module DC, 50 Hz, 60 Hz 50/60 Hz L, N, PE, L+N, L+PE, N+PE, L+N+PE, direct out 2 Ω: L-N, direct out, 12 Ω: L-PE, N-PE IMU-MGS Control Features Operating system Languages User interface Connectivity Environment meas. EUT power monitor EUT supply voltage waveform EUT supply current waveform Surge monitoring Surge voltage waveform Surge current...

Open the catalog to page 12
Conducted Immunity Testing - 13

power ON/OFF at selectable voltage angle (0 – 359°, 1° step) Impulse polarity positive, negative, alternating Automatic ramps test level, sync. angle, coupling path EUT overcurrent protection automatic programmable fuse up to 16 A PS3 control DC, 16.7 Hz, 50 Hz, 60 Hz supply power Safety features (standard) Emergency stop button on front panel red/yellow as per IEC 60947-5-5, IEC 60204-1, ISO 13850, Safety circuit Safety accessories WARNING LAMP (24 V, max. 2.4 W), (optional) TC-ST test cabinet Remote EMERGENCY STOP button IMU-MGS module: EXT-IMU P Application enhances CDN DC capability...

Open the catalog to page 13
Conducted Immunity Testing - 14

IMU-MGS module: EXT-IMU4000 F5, EFT / Burst extension 5.1 kV Standard Output impedance Voltage OC Voltage into 50 Ω Waveform into 50 Ω Voltage into 1 kΩ Waveform into 1 kΩ Spike frequency Maximum spikes / second Burst duration Burst repetition Polarity Synchronization Ramps Optional accessories IEC 61000-4-4 latest edition 50 Ω 0.2 kV – 5.1 kV 0.1 kV – 2.55 kV ± 10 % 5 ± 1.5 ns / 50 ± 15 ns 0.191 kV – 4.85 kV ± 20 % 5 ± 1.5 ns / 50 ns (-15/+100 ns) 1 kHz - 1 MHz 8000 @ 1 kV 0.01 ms - 30 ms, continuous up to 8 kHz 1 - 1000 ms positive, negative, alternating 0 – 359°, step 1° voltage, spike...

Open the catalog to page 14

All EMC PARTNER AG catalogs and technical brochures