Product Features
  • Performance and Sound Level: The units are engineered to minimize noise and vibrations, achieving sound levels as low as 28 dB(A). Key features include an acoustic jacket on scroll compressors, a fan speed controller, and insulation with acoustic foam.
  • Accessibility: Easy access is facilitated through three hinged doors with ¼ turn locks, allowing direct access to components, fans, and condensers.
  • Innovative Design: The design incorporates a hidden fan for improved aesthetics and unique airflow management, with a mini channel condenser reducing refrigerant charge by 40%.
  • Compactness: The units have optimized dimensions to reduce surface area to less than 0.6m², featuring a single fan design for all housing sizes and stackable options.
  • Flexibility: The platform supports multiple refrigerants (R404A, R449A, R452A, R134a, R513A) and includes a fully equipped electrical box and corrosion-resistant condenser treatment.
Product Information
  • High Capacity Range: The BIOMA range offers capacities from 0.5 kW to 10 kW, suitable for various refrigerants and applications (MBP and LBP).
  • Three Sizes Available: Housing dimensions are provided for three different sizes, ensuring a complete range to meet diverse needs.
  • Nomenclature: Detailed model descriptions include information on compressor family, production plant, cooling system, temperature, configuration, nominal capacity, application, and refrigerants.
General Data & Performance
  • Condensing Units: Specifications include input power, dimensions, weight, acoustics, cooling capacity, and connection diameters for various models, ensuring detailed performance data for different ambient temperatures and conditions.
Digital Tools
  • Not explicitly detailed in the provided text, but likely refers to tools for monitoring and managing unit performance.
General Overview: This document provides detailed specifications and performance data for various condensing units and compressors. It includes information on cooling capacities, power inputs, and dimensions for different models under varying ambient temperatures.
Specifications: The document lists multiple models of condensing units, each with specific voltage requirements, cooling capacities, and compressor models. For example, the UP-SE6043GS-EAE00 model operates at 400V-3ph-50Hz with a fan at 230V-1ph-50Hz, offering a cooling capacity range from 4421W to 14344W depending on the temperature.
Performance Data: Performance is measured across a range of temperatures, with cooling capacities provided for each model at specific ambient conditions. The document also includes Coefficient of Performance (COP) values, which indicate the efficiency of each unit.
Design and Dimensions: Each unit's design specifications include dimensions (width, depth, height), weight (net and gross), and acoustic levels. The document specifies the number of fans, fan diameter, and swept volume, which are critical for understanding the airflow and cooling efficiency.
Connection and Installation: Details on liquid receiver connection diameters and internal volumes are provided, which are essential for installation and integration into existing systems.
Refrigerants and Standards: The document mentions the use of refrigerants like R404A, R134a, and R452A, and references standards such as EN13215 for subcooling and midpoint calculations.
Notes: The document includes a disclaimer that specifications are subject to change without prior notice, emphasizing the need for users to verify details before application.
General Overview: The document provides detailed technical specifications and performance data for various condensing units and compressors. It includes information on cooling capacities, input power, dimensions, weight, acoustics, and connection diameters for different models.
Specifications: Each model is specified with its condensing unit model number, compressor model, voltage requirements, and cooling capacities at various ambient temperatures ranging from -35°C to -10°C. The document also lists the input power in watts, dimensions in millimeters, and weight in kilograms.
Performance Data: The performance data includes cooling capacities at different ambient temperatures, input power requirements, and COP/SEER values. The document provides detailed tables for each model, showing performance metrics at specific temperature points.
Procedures and Standards: The document references the EN13215 standard for subcooling and mid-point calculations. It also notes that the data is subject to alteration without prior notice, indicating adherence to industry standards and practices.
Recommendations and Notes: The document includes a note that the specifications are subject to change without notice, suggesting that users should verify the data before making decisions based on it.
Key Data Extraction: The tables provide cooling capacities and input power for each model at specified temperatures. The document also includes dimensions, weight, and acoustic data, which are critical for installation and operational considerations.
General Overview: The document provides technical specifications and performance data for various models of compressors, specifically focusing on hermetic reciprocating and scroll compressors. It includes details on configurations, stackability options, and wiring diagrams.
Specifications: The document lists multiple compressor models with their respective power requirements, fan specifications, and performance metrics. For example, models like UP-SE2006GK-EAE00 and UP-SE2006GS-EAE00 are detailed with their voltage, phase, and frequency requirements, along with performance data at different operational conditions.
Performance Data: Performance metrics are provided in tabular form, showing values such as capacity and power consumption at various conditions. These tables are crucial for understanding the operational efficiency and suitability of each compressor model for specific applications.
Configurations and Accessories: The document outlines different housing configurations and accessory codes, indicating compatibility and installation options. It also mentions stackability options and provides dimensions for different housing sizes.
Wiring Diagrams: Detailed wiring diagrams are included for both hermetic reciprocating and scroll compressors, specifying configurations for 230V single-phase and 400V three-phase systems.
Digital Tools: The document highlights the Embraco Toolbox App, which offers functionalities like a product selector, cross-reference, product catalogue, distributor locator, unit converter, refrigerant slider, and troubleshooting guide. It also promotes the Refrigeration Club for exclusive content and updates for refrigeration professionals.
Note: The document is subject to alterations without prior notice, with the last update noted as February 2020.
See more

Catalog excerpts

BIOMA-1

New Silent Units Range BIOMA Multi-Refrigerant Platform

 Open the catalog to page 1
BIOMA-2

GENERAL DATA & PERF ORMANCE

 Open the catalog to page 2
BIOMA-3

BIOMA PRODUCT FEATURES BIOMA PRODUCT FEATURES BIOMA RANGE MAIN FEATURES PERFORMANCE AND OPTIMIZED SOUND LEVEL • Robust design to absorb vibrations and noise • Sound level as low as 28 dB (A) • Acoustic jacket on scroll compressors • Fan speed controller as standard • 5 faces insulated with acoustic foam ACCESSIBILITY • 3 door access on hinges - ¼ turn door lock to open • Direct access to any component to be set or changed • Direct access to fan and condenser INNOVATIVE DESIGN • Hidden fan - stylish design for a new experience • Unique airflow management • Mini channel condenser: 40% less refrigerant...

 Open the catalog to page 3
BIOMA-4

BIOMA PRODUCT INFORMATIONS BIOMA PRODUCT INFORMATIONS THREE SIZES: A COMPLETE RANGE REFRIGERANTS MAP AND EQUIPMENT LEVEL COMPRESSORS FAMILY NOMINAL CAPACITY The first digit is the number of zeros that must be added to the last two digits to get (approximately) the cooling capacity in kcal/h at 50Hz. E.g: 214 --> 1400kcal/h at 50Hz Scroll: in BTU/h at 60Hz x 1000 - ARI conditions COOLING SYSTEM PRODUCTION PLANT

 Open the catalog to page 4
BIOMA-5

GENERAL DATA & PERFORMANCE GENERAL DATA & CONDENSING UNITS AMBIENT TEMP. CONNECTION DIAMETERS CONDENSING UNIT MODEL Seer WMtM ffleptW Wdglfl (kg) (kg) diameter volume Power Suction Liquid Suction Liquid Note: Subject to alteration without previous notice

 Open the catalog to page 5
BIOMA-6

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE R452A - MBP - SH10K CONDENSING UNITS AMBIENT TEMP. CONNECTION DIAMETERS CONDENSING UNIT MODEL Seer (Mil,) (Depth) OtelghU (kg) (kg) 'ewe! f°a'n diameter volume Power Suction Liquid Suction Liquid Note: Subject to alteration without previous notice

 Open the catalog to page 6
BIOMA-7

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE R449A - MBP - RTG20 CONDENSING UNITS AMBIENT TEMP. CONDENSING UNIT MODEL COMPRESSOR MODEL Note: Subject to alteration without previous notice

 Open the catalog to page 7
BIOMA-8

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE R449A - MBP - SH10K CONDENSING UNITS AMBIENT TEMP. CONNECTION DIAMETERS CONDENSING UNIT MODEL Seer (Mil,) (Depth) WagW (kg) (kg) 'ewe! f°a'n diameter volume Power Suction Liquid Suction Liquid Note: Subject to alteration without previous notice

 Open the catalog to page 8
BIOMA-9

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE R404A - MBP - RTG20 CONDENSING UNITS AMBIENT TEMP. CONNECTION DIAMETERS CONDENSING UNIT MODEL Seer WMtM (DeptW Wdglfl (kg) (kg) diameter volume Power Suction Liquid Suction Liquid Note: Subject to alteration without previous notice

 Open the catalog to page 9
BIOMA-10

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE AMBIENT TEMP. CONNECTION DIAMETERS CONDENSING UNIT MODEL diameter volume Power Suction Liquid Suction Liquid Note: Subject to alteration without previous notice

 Open the catalog to page 10
BIOMA-11

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE CONDENSING UNITS AMBIENT TEMP. CONNECTION DIAMETERS CONDENSING UNIT MODEL COMPRESSOR MODEL Sound Sound Number Note: Subject to alteration without previous notice 20

 Open the catalog to page 11
BIOMA-12

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE CONDENSING UNITS AMBIENT TEMP. CONNECTION DIAMETERS CONDENSING UNIT MODEL COMPRESSOR MODEL Sound Sound Number Note: Subject to alteration without previous notice 22

 Open the catalog to page 12
BIOMA-13

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE CONDENSING UNITS AMBIENT TEMP. LIQUID RECEIVER CONNECTION DIAMETERS CONDENSING UNIT MODEL COMPRESSOR MODEL (Width) (Depth) (Height) (kg) Sound Sound Number diameter volume Note: Subject to alteration without previous notice 24

 Open the catalog to page 13
BIOMA-14

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE CONDENSING UNITS AMBIENT TEMP. LIQUID RECEIVER CONNECTION DIAMETERS CONDENSING UNIT MODEL COMPRESSOR MODEL (Width) (Depth) (Height) (kg) Sound Sound Number diameter volume Note: Subject to alteration without previous notice 26

 Open the catalog to page 14
BIOMA-15

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE AMBIENT TEMP. LIQUID RECEIVER CONNECTION DIAMETERS CONDENSING UNIT MODEL COMPRESSOR MODEL (Width) (Depth) (Height) (kg) Sound Sound Number diameter volume Note: Subject to alteration without previous notice

 Open the catalog to page 15
BIOMA-16

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE AMBIENT TEMP. LIQUID RECEIVER CONNECTION DIAMETERS CONDENSING UNIT MODEL COMPRESSOR MODEL (Width) (Depth) (Height) (kg) Sound Sound Number diameter volume Note: Subject to alteration without previous notice

 Open the catalog to page 16
BIOMA-17

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE AMBIENT TEMP. CONNECTION DIAMETERS COMPRESSOR MODEL Note: Subject to alteration without previous notice

 Open the catalog to page 17
BIOMA-18

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE AMBIENT TEMP. EN13215 - SUBCOOLING OK - MID POINT ECO DESIGN RECEIVER CONNECTION DIAMETERS CONDENSING UNIT MODEL CONDENSING UNITl BOM VOLTAGE (V) COMPRESSOR MODEL Sound Sound Number Note: Subject to alteration without previous notice

 Open the catalog to page 18
BIOMA-19

EXTERNAL VIEWS HOUSING 2 (mm) STACKABILITY OPTIONS DIFFERENT HOUSING SIZES SAME HOUSING SIZE Different housing sizes with complementary bracket ACCESSORY CODE Housing 1 on Housing 2 Housing 1 on Housing 3 Housing 2 on Housing 3 SCREW M8x25 EXAGONAL HEAD

 Open the catalog to page 19
BIOMA-20

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE i POWER SUPPLY CABLE i (NOT SUPPLIED) GD CONNECTED TO I MAIN SWITCH TERMINALS I I CONNECTION ESTABLISHED FOR PUMP-DOWN, i | IN CASE OF EXTERNAL CONSENT REMOVE THE [ I BRIDGE FROM TERMINALS 3-4 AND CONNECT | I VOLTAGE FREE CONTACT (NOT SUPPLIED) :________________________________i I CONNECTION ESTABLISHED FDR PUMP-DOWN, I [IN CASE OF EXTERNAL CONSENT REMOVE THE| [BRIDGE FROM TERMINALS 3-4 AND CONNECT | I VOLTAGE FREE CONTACT (NOT SUPPLIED) I i________________________________i

 Open the catalog to page 20
BIOMA-21

GENERAL DATA & PERFORMANCE GENERAL DATA & PERFORMANCE LI L2L3 N I POWER SUPPLY CABLE I (NOT SUPPLIED) GO CONNECTED TO I MAIN SWITCH TERMINALS I i__________________i ["fan cdnnectidn"] IBU=BLUE |GY=GRAY i BN=BRDWN jjBK=BLACK iCONNECTION ESTABLISHED FOR PUMP-DOWN, I | IN CASE OF EXTERNAL CONSENT REMOVE THE| |BRIDGE FROM TERMINALS 3-4 AND CONNECT | I VOLTAGE FREE CONTACT (NOT SUPPLIED) I i________________________________i I CONNECTION ESTABLISHED FOR PUMP-DOWN, I [IN CASE OF EXTERNAL CONSENT REMOVE the] I BRIDGE FROM TERMINALS 3-4 AND CONNECT | I VOLTAGE FREE CONTACT (NOT SUPPLIED) I i________________________________i...

 Open the catalog to page 21
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.