Specifications and Testing Procedures
Columns can be designed and tested with dynamic and static loads exceeding current standards if specifically requested by the client. All columns undergo a series of tests to ensure compliance with structural calculations and suitability for overloads as per the EN 1493 (2010) directive. A specially designed machine is used for these tests, featuring a computerized control unit that manages data from a dedicated load cell interfacing with a hydraulic control unit equipped with special proportional valves and a variable capacity pump. The machine can handle capacities over 100 metric tons and is adaptable for testing columns ranging from 4 tons to over 60 tons.
Testing Procedures- Dynamic Overload: Tested at 15% above the nominal capacity for the entire lifting stroke.
- Static Overload: Tested at 50% above the nominal capacity at maximum height for at least one hour.
- Structural Deflections: Survey of column deflections and potential permanent deformations.
- Vibration Survey: Monitoring of vibrations emitted during dynamic tests.
- Electric Current Absorption: Measurement of current (Ampere) during dynamic tests.
- Safety Systems Functionality: Verification of safety systems such as wear nut sensor, obstacle sensor, lifting sensor, safety electronic endstrokes, and installed buttons.
Contact InformationEMANUEL srl, Via G. Marconi, 3, 40011 Anzola Emilia (BO) Italy. Tel. +39 051 732652 • 735217 • Fax +39 051 734001. Website: www.emanuel.it • Email: