EMSPALINEAR MAGNETOSTRICTIVE TRANSDUCER WITH ANALOGUE OUTPUT MAIN CHARACTERISTICS EMSPA is an absolute linear magnetostrictive transducer with analog interface. Thanks to the absence of electrical contact on the enclosure there is no issue of wear and deterioration during working life. Magnetostrictive technology guaranties great performances of speed and accuracy. High reliability and simple installation even for applications with mechanical stresses, shocks or high contamination are assured by the compact size and the rugged enclosure. SERIES linear magnetostrictive transducer with analogue output EMSPA STROKE mm from 50 to 1500 see table for stroke availability ENCLOSURE RATING IP 67 S OUTPUT SIGNAL 0 ... 10 VDC / 1 cursor (standard) 10S 0 ... 10 VDC / 1 cursor position/speed 10P 0 ... 10 VDC / 2 cursors (min. stroke 400 mm) 10D 4 ... 20 mA / 1 cursor 20S 4 ... 20 mA / 1 cursor position/speed 20P 4 ... 20 mA / 2 cursors (min. stroke 400 mm) 20D TRAVEL SPEED max speed 10 m/s 10 OUTPUT TYPE cable (standard length 1 m) P M12 5 pin connector S5 M12 8 pin connector S8 M16 DIN 45322 6 pin connector C6 M16 DIN 45326 8 pin connector C8 OUTPUT DIRECTION axial A © Copyright 2016 Eltra S.p.a. Unipersonale. All rights reserved. All informations in this catalog are subject to change without notice. Eltra takes no responsibility for typographic errors. For the terms of sales please check the website. REV. 160607 200
Open the catalog to page 1ELECTRICAL SPECIFICATIONS Resolution Output signal 16 bit (max electrical noise 5 mVpp) 0 ... 10 VDC Output alarm value Power supply Power ripple Current consumption Output load Output ripple Indipendent linearity < ± 0,01 % FS (min ± 0,060 mm) typical with sliding cursor < ± 0,02 % FS with floating cursor (working distance 2 ... 5 mm) < ± 0,04 % FS with floating cursor (working distance 5 ... 7 mm) Protection against overvoltage yes MECHANICAL SPECIFICATIONS Protection against polarity inversion Protection against power supply on output Electrical insulation Electromagnetic compatibility © Copyright...
Open the catalog to page 2CONNECTIONS S5 connector (5 pin) M12 A coded solder side view FV S8 connector (8 pin) M12 A coded solder side view FV C6 connector (6 pin) DIN 45322 solder side view FV C8 connector (8 pin) DIN 45326 solder side view FV The transducer enclosure has to be connected to ground only on the control system side by the cable shield, to guarantee the correct electrical insulation of the transducer from the machine, always assemble the brackets using the plastic washers included. For multi-cursor model, the cursors have to work in the same conditions of distance and temperature. Cursors must be installed...
Open the catalog to page 33 Pages
3 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
2 Pages
2 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
5 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
4 Pages
4 Pages