Overview: The document provides technical specifications and ordering information for the Eltra EMB electronic interface signal splitter. It is designed to adjust encoder electronic features to control systems, allowing for signal splitting and adaptation of output stages.
Ordering Code: The ordering code for the EMB series includes options for input voltage, input electronics, output voltage, output electronics, version, and variant. For example, a board with a 5 V DC NPN input and eight 5 V DC line driver outputs is coded as EMB5N5L5L5L5L5L5L5L5L.
Main Features: The EMB board can handle up to two different voltages and must be supplied through the X4 connector with the highest voltage used. It can produce up to 8 outputs from a single input by assembling multiple boards, reducing wiring complexity.
Mechanical Specifications: The enclosure rating is IP00, with an operating and storage temperature range of -20° to +85°C. The board is mounted on a DIN 46277-3 or DIN 46277-2 rail and weighs 150 g per module.
Electrical Specifications: Power supply options include 4.5-5.5 V DC, 7.6-25.2 V DC, and 22.8-25.2 V DC. The maximum current consumption is 1340 mA, considering multiple modules and outputs. The board is compatible with various output types, including NPN, NPN open collector, push-pull, and line driver.
Input Electronic Specifications: The board supports different input types with varying maximum load currents and input frequencies, such as 5P (TTL compatible) and 5L (RS-422 compatible).
Application Examples: The document includes examples of terminal board connections and signal adaptation scenarios, illustrating how the EMB board can be used in different configurations to connect encoders and control systems.
See more

Catalog excerpts

EMB-1

EMB ELECTRONIC INTERFACE SIGNAL SPLITTER MAIN FEATURES This board is used when it is necessary to adjust encoder electronic features to control ones. Main functions of EMB are output signal splitting and adaptation of output stages. For instance, it happens to have an encoder with 5 V DC output and a control that accepts only 24 V DC inputs. It may also happen to use an encoder connected with a control with the same power supply, but different electronics. It can solve a wide range of problems: check the ordering code to find further informations. On the board there can be up to 2 different voltages and it must be supplied through the X4 connector with the higher voltage used. Moreover it is possible to obtain up to 8 outputs from the same input by assembling several boards in a single support in order to reduce wirings drastically. In this case the ordering code will contain informations about all outputs. For example, a board with one 5 V DC NPN input and eight 5 V DC line driver outputs has the following ordering code: EMB5N5L5L5L5L5L5L5L5L. ORDERING CODE SERIES signal splitter EMB INPUT OPTION * add to ordering code for optically isolated input INPUT VOLTAGE X1 CONNECTOR 5 V DC 5 (mod. EMB) 8 ... 24 V DC 8/24 (mod. EMBO) 24 V DC 24 INPUT ELECTRONICS X1 CONNECTOR (mod. EMB) NPN N (mod. EMB) NPN open collector C push-pull P line driver L (mod. EMB) PNP R OUTPUT VOLTAGE (OUT1) X2 CONNECTOR 5 V DC 5 (mod. EMB) 8 ... 24 V DC 8/24 (mod. EMBO) 24 V DC 24 OUTPUT ELECTRONICS (OUT1) X2 CONNECTOR (mod. EMB) NPN N (mod. EMB) NPN open collector C push-pull P line driver L OUTPUT VOLTAGE (OUT2) X3 CONNECTOR 5 V DC 5 (mod. EMB) 8 ... 24 V DC 8/24 (mod. EMBO) 24 V DC 24 OUTPUT ELECTRONICS (OUT2) X3 CONNECTOR (mod. EMB) NPN N (mod. EMB) NPN open collector C push-pull P line driver L VERSION version 2 .2V The following example may explain better a typical EMB application: an encoder with 5 V DC RS-422 output has to be connected to a 24 V DC push-pull input and also to an instrument with 5 V DC RS-422 input. Ordering code will be: EMB5L8/24P5L where VARIANT custom version XXX EMB5L indicates 5 V DC line driver input on X1 connector EMB5L8/24P indicates 24 V DC push-pull output on X2 connector EMB5L8/24P5L indicates 5 V DC line driver output on X3 connector Power supply of this board is 24 V DC, because it is the highest used value, and it will be supplied through X4 connector. © Copyright 2016 Eltra S.p.a. Unipersonale. All rights reserved. All informations in this catalog are subject to change without notice. Eltra takes no responsibility for typographic errors. For the terms of sales please check the website. REV. 160607

 Open the catalog to page 1
EMB-2

Single implementation Multiple implementation (4 modules / 8 outputs max) 90 90 90 90 ELECTRICAL SPECIFICATIONS X1 INPUT ELECTRONIC SPECIFICATIONS Power supply Input type * depending on lenght and cable specs *output levels according to power supply, for further details please see under Technical basics section © Copyright 2016 Eltra S.p.a. Unipersonale. All rights reserved. All informations in this catalog are subject to change without notice. Eltra takes no responsibility for typographic errors. For the terms of sales please check the website. REV. 160607 229

 Open the catalog to page 2
EMB-3

TERMINAL BOARD CONNECTIONS ®<$>® TOCID, board power supply wire insertion side wire insertion side signal connections power supply connections APPLICATION EXAMPLES ELECTRONIC SIGNALS SIGNAL AMPLIFIER © Copyright 2016 Eltra S.p.a. Unipersonale. All rights reserved. All informations in this catalog are subject to change without notice. Eltra takes no responsibility for typographic errors. For the terms of sales please check the website. REV. 160607 230

 Open the catalog to page 3

All Eltra S.p.a. catalogs and technical brochures

  1. EC 34

    3  Pages

  2. EP A / B

    2  Pages

  3. EMD

    2  Pages

  4. EV B / C

    2  Pages

  5. EMI 30 M

    2  Pages

  6. EF 36 K

    2  Pages

  7. EH - EL 88 P

    2  Pages

  8. EH 99 P

    2  Pages

  9. EH 17 - 30 MH

    2  Pages

  10. EH 50 FA / FP

    2  Pages

  11. EL 120 P

    2  Pages

  12. EMI 63 A / D

    2  Pages

  13. EMI 55 A / AY

    2  Pages

  14. EMI 40 A

    2  Pages

  15. EL 48 C / P

    2  Pages

  16. ETMR

    2  Pages

  17. EH 17 - 30 M

    2  Pages

  18. EL - ER 40

    3  Pages

  19. EMI 22 A

    2  Pages

  20. EMI 38 F / G

    2  Pages

  21. EMSPA

    3  Pages

  22. EMSSA

    3  Pages

  23. EPLC

    2  Pages

  24. EBMA

    2  Pages

  25. EMSSS

    3  Pages

  26. EMSPS

    2  Pages

  27. FES

    2  Pages

  28. EMSPB

    2  Pages

  29. EPLB

    2  Pages

  30. ETMA 1 / 2

    2  Pages

  31. FE

    2  Pages

  32. EPLT

    2  Pages

  33. EA 36 A SSI

    2  Pages

  34. EA 63 AX / DX

    2  Pages

  35. EMA 22 A

    2  Pages

  36. EAMX 80 A / D

    3  Pages

  37. EAM 36 A

    2  Pages

  38. EA 36 F / G

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.