ELP-PFA

ELP-PFA

ELP-PFA

Product catalog summary
Overview: This document provides technical specifications and guidelines for ELP-PFA trace heaters, which are used in various industries such as chemistry, petrochemistry, building construction, food processing, and paper industry. These heaters are designed for temperature maintenance and freeze prevention in pipelines, silos, vessels, and tanks.
Specifications:
  • Maximum withstand temperature: 260 °C
  • Nominal voltage: 230 VAC up to 277 VAC
  • Max. Current: 40 A
  • Min. Bending radius: 25 mm
  • Min. installation temperature: –60 °C
  • Moisture proof
Construction:
  • Bus wire: Copper
  • 1st and 2nd insulation: Fluoropolymer
  • Heating conductor: Heating conductor alloy
  • Protective braid: Copper, nickel-plated
  • Outer jacket: Fluoropolymer
Certifications:
  • IECEx EPS 12.0009 U
  • IECEx EPS 21.0062 X
  • EPS 12 ATEX 1438 U
  • EPS 21 ATEX 1198 X
Features:
  • Single end power input
  • Can be cut to length
  • Constant power output per meter
  • High chemical resistance
  • UV-resistance
  • Flexible
Installation and Usage:
  • Constant wattage trace heater with resistance wire
  • Quick and easy to assemble, reducing costs
  • Output of up to 60 W/m suitable for high output requirements
  • Connection & end termination sets available for different temperature ranges
Technical Information:
  • Heating circuit lengths depend on circuit breaker and start-up temperature
  • Greater lengths possible with higher rated circuit breakers
  • Protection by circuit breaker RCD 30 mA required
  • Standards to observe: IEC 62395-2, EN 60519-10, EN 62395-2
Ordering Information:
  • ELP/PFA 15 BOT: 15 W/m, max. maintain temperature 200 °C
  • ELP/PFA 30 BOT: 30 W/m, max. maintain temperature 200 °C
  • ELP/PFA 45 BOT: 45 W/m, max. maintain temperature 200 °C
  • ELP/PFA 60 BOT: 60 W/m, max. maintain temperature 180 °C
See more

Catalog excerpts

ELP-PFA-1

Freeze prevention Temperature maintenance Silos, vessels, tanks Chemistry and Petrochemistry Building construction Food Processing Industry Paper industry Benefits Single end power input Can be cut to length Constant power output per meter High chemical resistance UV-resitance flexible Heating conductor alloy Copper, nickel-plated Constant wattage trace heater with resistance wire These parallel trace heaters offer tremendous flexibility in use, as they can easily be cut to the required length off the roll, with the assurance of constant power output. There is no need for a connecting cable and input can be unilateral. It is quick and easy to assemble; this saves a lot of time, and reduces costs considerably as a result. Since output of up to 60 W/m is possible for lengths laid to piping, ELP parallel trace heaters are particularly suitable for piping with high output requirements such as in industrial process technology. The particularly temperature-resistant outer shell in Fluoropolymer and the high level of chemical resistance of the Fluoropolymer ensure a long useful life. Checklist Trace Heater classification II 2G Ex 60079-30-1 IIC Gb II 2D Ex 60079-30-1 IIIC Db System classification II 2G Ex 60079-30-1 IIC T6..T2 Gb II 2D Ex 60079-30-1 IIIC Txx°C Db Certification IECEx EPS 12.0009 U IECEx EPS 21.0062 X EPS 12 ATEX 1438 U EPS 21 ATEX 1198 X Silicone termination cap, transparent; for ELP/PFA up to 200 °C Silicone termination cap, red; for ELP/PFA up to 260 °C Silicone termination cap, red; for ELP/PFA up to 260 °C, Ex-marking Power connection kit, cold assembly, gland M25, PC Power connection kit, cold assembly, gland M25, PE, Ex e Power connection kit, cold assembly, gland M20, brass, Ex d e 122 x 120 x 90 mm, polyester, IP66, 1 - 3 Trace heaters, 1 Power cable 110 x 75 x 57 mm, polyester, IP66, 1 Trace heater, 1 Power cable 122 x 120 x 90 mm, polyester, IP66, 1 - 3 Trace heaters, 1 Power cable

 Open the catalog to page 1
ELP-PFA-2

Technical Information Maximum withstand temperature Nominal voltage Cross section bus wire Moisture proof * 277 VAC operation only approved for ELP/PFA 15W/m, 30 W/m and 45 W/m! Nominal output factor 230 V vs. 277 V = 1,45 Heating zone PE active heating element ELP/PFA 15 BOT ELP/PFA 30 BOT ELP/PFA 45 BOT ELP/PFA 60 BOT Length @ start up temp. Heating circuit lenght factor 230 V vs. 277 V = 0,83 Heating circuit lengths ELP/PFA on the following conditions: 16 A circuit breaker, 80 % utilisation, start up temp. +10°C Max. 10% voltage drop Power connection to one (1) heater end Greater lengths are...

 Open the catalog to page 2

All Eltherm catalogs and technical brochures

  1. ELSR-SH+

    2  Pages

  2. TOOL BOX

    2  Pages

  3. Ex-It-LA

    2  Pages

  4. ELP-FEP

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.