Overview: The Terra-Control TUE30 ground monitoring system is designed for safe handling of potentially explosive materials by eliminating static charges. It ensures proper grounding to reduce risks of explosions or fires.
System Components: The TUE30 system includes two main design versions:
  • TERRACOMPACT II TCO030: A standard enclosure for mounting on a rail in control panels or rooms.
  • TERRABOX TCB030: A wall-mounted enclosure for installation in hazardous zones.
Both versions can connect to ground clamps or cable rewinders, with the capability to connect two ground clamps for BIG BAG grounding.
Technical Specifications:
  • TERRABOX TCB030:
    • Supply Voltage: 24 V DC, 115 V AC, or 230 V AC.
    • Operating Temperature: -20 to +70°C.
    • Protection Class: IP 64.
    • Weight: Approx. 5 kg.
    • Approval: ATEX certified.
  • TERRACOMPACT II TCO030:
    • Supply Voltage: 24 V DC.
    • Operating Temperature: -20 to +70°C.
    • Protection Class: IP 40.
    • Weight: Approx. 200 g.
    • Approval: ATEX certified.
Safety and Compliance: Both systems are intrinsically safe and comply with EN 60079 standards. They feature potential-free changeover contacts and are designed to operate safely within specified voltage and current limits.
Installation and Usage: The TERRACOMPACT II is installed on a standard rail outside explosion hazard areas, while the TERRABOX is suitable for hazardous zones. Both systems provide visual indicators for operational status.
See more

Catalog excerpts

Technical information TUE30 Terracompact-1

The TUE30 Terra-Control ground monitoring system is designed for use when filling or discharging potentially explosive materials. The system effectively eliminates any static charges. The proper ground connection of installations reduces the risk of uncontrolled explosions or fires. The TUE30 system monitors the connection to the bonding conductor and the contact across the ground clamps. This function controls a potential-free changeover contact, which allows to controle optical or acoustic primary detectors, locking mechanisms, pumps, slide valves etc. The modular system of the Terra-Control TUE30 is available in the following design versions: • TERRACOMPACT II TCO030, standard enclosure for mounting on a standard rail NS35 for installation in a control panel or control room • TERRABOX TCB030, wall-mounted enclosure for direct installation in the hazardous zone. Technical Information Ground monitoring system Terra-Control TUE30 TI-en-4003-2002 TERRACOMPACT II and TERRABOX are each designed for connecting one ground clamp or a cable rewinder fitted with ground clamp. For BIG BAG grounding, two ground clamps can be connected to the TERRABOX and to the TERRACOMPACT II.

 Open the catalog to page 1
Technical information TUE30 Terracompact-2

Ground monitoring system TUE30 with TERRACOMPACT II TCO030 and with TERRABOX TCB030 Hazardous area (zone 1/21) Safe area TERRACOMPACT II TCO030 Cable rewinder, aluminum, 601KR/AW or 601KR/DW with ground clamp Cable rewinder, plastic, 601KR/KW with ground clamp Ground clamp Ground cable KG/BNA Ground helix cable KG/BSA TERRABOX TCB030

 Open the catalog to page 2
Technical information TUE30 Terracompact-3

Supply voltage* Ambient operating temperature Storage temperature Ambient humidity Enclosure material Protection class Dimensions Weight Indicator signal (Contact circuit) Measurement circuit Operating points Approval / Identification TCB030/_0: 24 (21. ..31) V DC, 100 mA TCB030/_1: 115 (105.125) V AC 50/60 Hz, 100 mA TCB030/_2: 230 (210.250) V AC 50/60 Hz, 50 mA Maximum safety voltage Um = 250 V -20.+70°C (-4.+158°F) -20.+80°C (-4.+176°F) max. 80% r.h., non-dewing; BIG BAG design: max. 70% r.h. sheet metal steel with wall bracket, enameled IP 64 according to EN 60529 211 x 211 x 123 mm (H x...

 Open the catalog to page 3
Technical information TUE30 Terracompact-4

Technical specifications TERRACOMPACT II TCO030 Supply voltage* Power input Operating ambient temperature Ambient humidity Design Protection class Dimensions Weight Assembly Connection Indicator signal Measurement circuit Operating points Identification Approval 24 (21. ..31) V DC maximum voltage for safety reasons: Um = 250 V IB typical 80 mA -20...+70°C (-4... + 158°F) maximum 70% r.h., non-dewing Standard enclosure for installation on standard rail NS35 Enclosure IP 40; (terminals IP 10) 68 x 45 x 116 mm (H x W x D) approx. 200 g Assembly on NS35 standard rail, path height 15 mm; outside explosion...

 Open the catalog to page 4

All Eltex-Elektrostatik-GmbH catalogs and technical brochures

  1. Brochure ESA

    15  Pages

  2. Brochure SDS

    4  Pages

  3. Brochure RX3

    3  Pages

  4. Brochure WM3000

    15  Pages

  5. Brochure SCC

    3  Pages

  6. Brochure RX11

    3  Pages

  7. Brochure MTS

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.