Overview: The Smart Discharging System (SDS) is designed to eliminate disruptive static charges over medium distances. It features integrated high voltage generation, a robust and compact design, and is shockless, ensuring safety for personnel. The system is easy to install and maintain, with function and malfunction monitoring capabilities.
Specifications:
  • Supply Voltage: 24 V DC ±10%
  • Input Current: max. 0.5 A
  • Power Input: max. 12 W
  • Output Voltage: SDS/N: ±7 kV; SDS/E: ±11 kV
  • Working Distance: SDS/N: min. 100 mm; SDS/E: min. 150 mm
  • Operating Temperature: +5...+50°C (+41...+122°F)
  • Storage Temperature: -20...+80°C (-4...+176°F)
  • Humidity: max. 80% r.F., non-dewing
  • Protection Class: IP 66 according to EN 60529
Variants: The SDS is available in four variants, differentiated by operating range and interface:
  • SDS/N for close range with active lengths from 330 mm to 3,990 mm and grid spacing of 60 mm.
  • SDS/E for enlarged range with active lengths from 315 mm to 3,905 mm and grid spacing of 90 mm.
  • SDS/_S with fault signal output.
  • SDS/_C with CANopen® interface.
Installation and Mounting: The discharging bar features a groove for positioning holders at regular intervals. It is secured by tightening bolts. The bar should be positioned so that the distance between emission tips and the object is less than the distance to grounded components.
Connection Details:
  • Fault Signal Output Variant: 5-pin connector with specific pin functions for fault signal, supply voltage, and grounding.
  • CANopen® Variant: 5-pin connector with specific pin functions for CAN High and CAN Low signals.
Contact Information: Eltex-Elektrostatik-Gesellschaft mbH, Blauenstraße 67-69, D-79576 Weil am Rhein. Phone: +49 (0) 76 21/ 79 05 - 230, Email: [email protected], Website: www.eltex.com
See more

Catalog excerpts

Technical information SDS-1

The Smart Discharging System is used mainly in cases where disruptive static charges need to be eliminated over medium distances. The advantages of the Smart Discharging System SDS: • integrated high voltage generation • high output voltage for medium discharge range • a long life emission tip realized with an optimized high-performance material of the emission tip • shockless - no danger of electrical shock to personnel • robust, compact design • profile easy to clean • easy installation • function and malfunction monitoring of the system with fault signal output • crosslinking of the bar in CANopen® networks Technical Information Smart Discharging System Discharging Bar SDS for 24 V DC

 Open the catalog to page 1
Technical information SDS-2

1 Connector M12 2 Operating display Status-LED 3 Operating display CANopen®-Status-LED 4 Holder EL = Installation Length AL = Active Length GL = Total Length X = Distance first resp. last tip (depending on the operating space)

 Open the catalog to page 2
Technical information SDS-3

The use of the SDS/N and SDS/E discharging bars depends on the material to be discharged, the process speed, the distance to the material and the required residual charge. Please contact a member of the Eltex sales team to determine the variant required for your application. The discharging bar SDS is available in 4 different variants. Different configurations with regard to operating range and/or interface are available: • Operating range SDS/N Close range: Active length: 330 mm - 3,990 mm grid spacing 60 mm SDS/E Enlarged range: Active length: 315 mm - 3,905 mm grid spacing 90 mm • Interface...

 Open the catalog to page 3
Technical information SDS-4

The discharging bar SDS must be positioned such that the distance between the emission tips and the object to be discharged is smaller than the distance to the grounded machine components, in simpler terms, this corresponds to a circle with a radius R around the emission tips. Technical data discharging bar SDS Supply voltage Input Current Power Input Output voltage Working distance Ambient operating temperature Storage temperature Ambient humidity Short-circuit / tip Fault signal output Circular connector Protection class Mounting material Dimensions 24 V DC ±10 % max. 0.5 A max. 12 W SDS/N:...

 Open the catalog to page 4

All Eltex-Elektrostatik-GmbH catalogs and technical brochures

  1. Brochure ESA

    15  Pages

  2. Brochure SDS

    4  Pages

  3. Brochure RX3

    3  Pages

  4. Brochure WM3000

    15  Pages

  5. Brochure SCC

    3  Pages

  6. Brochure RX11

    3  Pages

  7. Brochure MTS

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.