1. Catalogs
  2. Eltako Electronics
  3. THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER

THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER

THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER
1 / 30 PagesView full catalog

THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER

Product catalog summary
Introduction
The document introduces the Series 15 energy meters, designed for precise metering and visualization of electrical energy consumption. These meters are available in both MID certified and non-certified versions, ensuring compliance with current standards.
Product Overview
The document details various energy meters, including three-phase and single-phase models, highlighting specifications such as maximum current, standby loss, and accuracy class. It also notes the availability of different interfaces like S0, M-bus, and RS485.
Specifications and Features
  • Three-phase Meter DSZ15D-3x80A MID: Features a maximum current of 3x80 A, low standby loss, and an S0 interface, with a 7-segment LC display and double-tariff metering support.
  • CT Operated Three-phase Meter DSZ15WD-3x5A MID: Designed for use with current transformers, allowing CT ratio settings and featuring an S0 interface.
  • M-bus Three-phase Meter DSZ15DM-3x80A MID: Equipped with an M-bus interface for data transfer and supports double-tariff metering.
Installation and Usage
Installation instructions emphasize connecting the N terminal and using MODE and SELECT keys for menu navigation. Guidance is provided for setting CT ratios and changing M-bus addresses.
Technical Data and Compliance
The meters comply with the Measuring Instruments Directive (MID), ensuring EU standards for accuracy and reliability. Technical data includes dimensions and power consumption.
Conclusion
The Series 15 energy meters offer comprehensive solutions for energy measurement and visualization, catering to diverse installation needs with compliance to international standards.
Three-Phase Energy Meters
  • DSZ14DRS-3x80A: A wireless meter with a maximum current of 80A, featuring RS485 interface and MID approval, designed for DIN-EN 60715 TH35 rail mounting.
  • DSZ14WDRS-3x5A: Similar to DSZ14DRS but with a maximum current of 5A and adjustable CT ratios.
Single-Phase Energy Meters
  • WSZ15D-32A MID: A single-phase meter with a maximum current of 32A, featuring an S0 interface and a 7-segment LC display.
  • WSZ15D-65A MID: Similar to WSZ15D-32A but with a maximum current of 65A.
  • WSZ15DE-32A: A non-MID approved meter with a maximum current of 32A and a digital display.
  • WZR12-32A: A meter with reset functionality, without MID approval, featuring a display for cumulative and instantaneous values.
Mobile Single-Phase Energy Meters
  • WSZ110DSS-16A MID: A mobile meter with a German type plug, suitable for indoor and outdoor use, with a maximum current of 16A.
  • WSZ110CEE-16A MID: Similar to WSZ110DSS but with a CEE plug and coupling.
Software and Accessories
  • GFVS-Energy: Wireless visualization and control software for up to 100 electricity meters, requiring a FAM-USB wireless receiver/transmitter for PC reception.
Energy Meter Transmitter Modules
The FSS12 module connects to the S0 interface of meters, featuring a load shedding relay and an exchangeable antenna. It supports up to 100 transmitter modules with GFVS-Energy software.
Functionality
The FSS12 module evaluates signals from meters and transmits wireless telegrams containing consumption and meter readings.
Display and Controls
The display shows unit of meter reading, instantaneous energy consumption, and cumulative meter reading. Wireless telegrams are sent every 130 seconds or sooner if power changes by at least 10%.
Additional Devices
Details on devices like the FEA65D-wg wireless energy consumption indicator and FWZ14-65A RS485 bus wireless single-phase energy meter are provided.
Installation and Operation
Installation involves connecting devices to the Eltako-RS485 bus and configuring settings using MODE and SET buttons.
Pricing
Recommended retail prices are provided for each device, excluding VAT.
Device Specifications
Designed for DIN-EN 60715 TH35 rail mounting, the device connects to the Eltako-RS485 bus, providing data from an electronic domestic supply meter to the RS485 bus.
Functionality and Operation
The device features a green LED for data reception indication and transmits data wirelessly via the FAM14 antenna module.
Operating Modes
The rotary switch allows selection of operating modes based on OBIS codes.
Installation and Connection
The AIR IR scanner connects to the meter's IR output, with pricing details provided.
Wireless Actuator Specifications
FSR61VA-10A and FSVA-230V-10A are wireless actuators with integrated current measurement, supporting encrypted and bidirectional communication.
Technical Data for Energy Meters
Complying with EN 50470, meters require surge protection and feature LC displays and various interfaces.
Installation Instructions
Instructions for electricians are provided, with support available from Eltako GmbH.
See more

Catalog excerpts

THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-1

THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER

 Open the catalog to page 1
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-2

Three-phase and single-phase energy meters

 Open the catalog to page 2
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-3

INTELLIGENTLY MEASURE AND VISUALIZE POWER Our Series 15 three-phase and single-phase energy meters offer you a range of varied and low-cost applications when requirements call for metering and visualising electrical energy consumption. Our modern high quality precision meters conform with current standards and the demands put on them. Our products are guaranteed and great care is taken in their construction in conjunction with Quality Management Processes. You can count on our products, no matter whether you opt for a MID certified device or a lower cost non certified version. Three-phase and...

 Open the catalog to page 3
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-5

Selection table three-phase meters and single-phase energy meters6 Three-phase meter DSZ15D-3x80A MID7 Three-phase meter DSZ15DE-3x80A, without MID approval8 CT operated three-phase energy meter DSZ15WD-3x5A MID9 M-bus three-phase energy meter DSZ15DM-3x80A MID10 M-bus CT operated three-phase energy meter DSZ15WDM-3x5A MID11 RS485 bus wireless three-phase energy meter DSZ14DRS-3x80A MID12 RS485 bus wireless three-phase energy meter DSZ14WDRS-3x5A MID13 Single-phase energy meter WSZ15D-32A MID14 Single-phase energy meter WSZ15D-65A MID15 Single-phase energy meter WSZ15DE-32A, without MID approval16...

 Open the catalog to page 5
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-6

SELECTION TABLE THREE-PHASE AND SINGLE-PHASE ENERGY METERS Depending on the customer's installation, only a conventional meter panel is required for billing with the electricity supply operator. On the other hand, dwellings and businesses can be billed using small three-phase meters installed in power distribution panels. See the installation instructions for electricians on page 10-25. It is then the task of the building management service to read the intermediate meter. This either takes place at the same time as heating consumption is read or centrally, e.g. when the meter interface is evaluated....

 Open the catalog to page 6
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-7

THREE-PHASE ENERGY METER DSZ15D-3X80A MID DSZ15D-3X80A MID Bl Maximum current 3x80 A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70 mm wide and 58 mm deep. Accuracy class B (1%). With S0 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 80 A can be connected. The inrush current is 40 mA. The N terminal must always be connected. The 7 segment LC display...

 Open the catalog to page 7
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-8

soon: aaoos 13 Typical connection 4-wire-connection 3x230/400 V DSZ15DE-3X80A Maximum current 3x80 A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70 mm wide and 58 mm deep. Accuracy class B (1%). With S0 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. 1, 2 or 3 phase conductors with max. currents up...

 Open the catalog to page 8
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-9

CT OPERATED THREE-PHASE ENERGY METER DSZ15WD-3X5A MID DSZ15WD-3X5A MID D CT operated three-phase energy meter with settable CT ratio and MID. Maximum current 3x5 A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70 mm wide and 58 mm deep. Accuracy class B (1%). With S0 interface. This three-phase energy meter measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 5 A can be...

 Open the catalog to page 9
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-10

M-BUS THREE-PHASE ENERGY METER DSZ15DM-3X80A MID Typical connection 4-wire-connection 3x230/400 V DSZ15DM-3X80A MID B M-bus three-phase energy meter. Maximum current 3x80 A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70 mm wide and 58 mm deep. Accuracy class B (1%). With M-bus interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 80 A can be connected. The...

 Open the catalog to page 10
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-11

M-BUS CT OPERATED THREE-PHASE ENERGY METER DSZ15WDM-3X5A MID DSZ15WDM-3X5A MID B M-bus CT operated three-phase energy meter with settable CT ratio and MID. Maximum current 3x5 A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70 mm wide and 58 mm deep. Accuracy class B (1%). With M-bus interface. This three-phase meter measures active energy by means of the currents flowing between inputs and outputs. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. 1, 2 or 3 converters with secondary currents...

 Open the catalog to page 11
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-12

RS485 BUS WIRELESS THREE-PHASE ENERGY METER DSZ14DRS-3X80A MID RS485 bus wireless three-phase energy meter. Maximum current 3x80 A. Standby loss 0.8 W at L1 and only 0.5 W at L2 and L3 each. Modulair device for DIN-EN 60715 TH35 rail mounting in distribution cabinets with IP51 protection class. 4 modules = 70 mm wide and 58 mm deep. Accuracy class B (1%). With RS485 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.8 W or 0.5 W active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents...

 Open the catalog to page 12
THREE-PHASE AND SINGLE-PHASE ENERGY METERS INTELLIGENTLY MEASURE AND VISUALIZE POWER-13

RS485 BUS WIRELESS THREE-PHASE ENERGY METER, MID APPROVAL DSZ14WDRS-3X5A MID PROFESSIONAL STAN DARD DSZ14WDRS-3X5A MID D RS485 bus wireless three-phase energy meter with settable CT ratio and MID. Maximum current 3x5 A. Standby loss 0.8 W at L1 and only 0.5 W at L2 and L3 each. Modulair device for DIN-EN 60715 TH35 rail mounting in distribution cabinets with IP51 protection class. 4 modules = 70 mm wide and 58 mm deep. Accuracy class B (1%). With RS485 interface. This three-phase energy meter measures active energy by means of the current between input and output. The internal power consumption...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.