Products and prices 2012 Switchgear, power supply units and electronic energy meters for installation in buildings and use in control technology Switching on the future 02/2012

Open the catalog to page 1
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 2

Pictograms The performance of our switchgear has become so complex that we have devised pictograms to depict technical features of particular importance. min ([) Minimized standby loss of electronic devices supports international efforts to reduce energy consumption. 98% of the switchgear and power supply units produced by ELTAKO have a standby loss of less than 0.6 watt. [X) No standby loss: this has always been a feature of electromechanical switchgear. Now some of our electronic switchgear devices have this capability too due to a patent Eltako technologie. Bistable switching relays help...

Open the catalog to page 2
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 3

Contents ELECTRONICS Electronic impulse switches also with release delay, for central control and with multifunction A Universal dimmer switches, 1-10V controller, capacity enhancer and motor dimmer also for central control and with multifunction B Electronic switching relays, control relays and coupling relays also with multifunction C Staircase time switches and off-delay timers also with multifunction D Time relays. multifunction time relays and timer digital and analogue, settable E Smart Metering - Visualising and indicating the smart way with Eltako single-phase energy meters and...

Open the catalog to page 3
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 4

untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.25pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Arial", sans-serif; } .font4 { font:10.00pt "Arial", sans-serif; } .font5 { font:11.00pt "Arial", sans-serif; } .font6 { font:15.00pt "Arial", sans-serif; } .font7 { font:16.00pt "Arial", sans-serif; } .font8 { font:26.00pt "Arial", sans-serif; } .font9 { font:7.00pt "Franklin Gothic Medium", sans-serif; } .font10 { font:12.00pt "Sylfaen", serif; } Key to type...

Open the catalog to page 4
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 5

ELECTRONICS Slection table electronic impulse switches A0 Impulse switch ES12DX A1 Impulse switch ES12-200 A2 Impulse switch ES12-110 A3 Impulse switch with integrated relay function ESR12NP A4 Digital settable multifunction impulse switch with integrated relay function ESR12DDX A5 Impulse switch with potential free contacts ES12Z, also for central control A6 4-fold impulse switch with integrated relay function ESR12Z-4DX-UC, also for central control and group control A7 Impulse switch ES6 A8 Impulse switch with integrated relay function ESR61NP A9 Multifunction impulse switch with...

Open the catalog to page 5
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 6

untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:9.00pt "Arial", sans-serif; } .font5 { font:15.00pt "Arial", sans-serif; } .font6 { font:20.00pt "Arial Black", sans-serif; } .font7 { font:4.00pt "Lucida Sans Unicode", sans-serif; } Slection Table Electronic Impulse Switches The silent rvolution Without attracting particular attention by switching noise, the importance of...

Open the catalog to page 6
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 7

ipulse Switch ES 121 ELECTRONICS ES12DX-UC cvivlO-MOVDC 53 C3 KO (N) © +A1 5mA 1 1 -A2 2 -A2 2 1 NO contact potential free 16A/250V AC. Incandescent lamp load up to 2000W. No standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18 mm wide, 58 mm deep. With the patented Eltako Duplex technology (DX) the normally potential-free contacts can still switch in zero passage when switching 230 V AC 50 Hz and therefore drastically re˭duce wear. Simply connect the neutral conductor to the terminal (N) and L to 1(L) for this. This results in an standby consumption of only 0.1...

Open the catalog to page 7
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 8

Impulse Switch ES 12-200 ES12-200-8..230V UC [>K] cvivlO-MOVDC 53 C3 1 3 +A1 5mA ^-fAl 1 3 -A2 2 4 -A2 2 4 2 NO contacts potential free 16A/250V AC. Incandescent lamp load up to 2000W. No standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18 mm wide, 58 mm deep. Either universal control voltage 8 to 230V UC at the control input +A1/A2 or 230 V with glow lamp current up to 5 mA at the control input -©- (L)/-A2(N). The simultaneous use of two potentials at the control inputs is not permitted. Very low switching noise. No permanent power supply necessary, therefore no...

Open the catalog to page 8
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 9

ipulse Switch ES12-1H ELECTRONICS ES12-110-8..230V UC cvivlO-MOVDC 53 C3 1 3 +A1 5mA ^+A1 1 3 1 1 1 1 -A2 1 2 4 -A2 2 4 1 NO contact + 1 NC contact potential free 16A/250V AC. Incandescent lamp load up to 2000W. No standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18 mm wide, 58 mm deep. Either universal control voltage 8 to 230V UC at the control input +A1/A2 or 230 V with glow lamp current up to 5 mA at the control input ■& (L)/-A2(N). The simultaneous use of two potentials at the control inputs is not permitted. Very low switching noise. No permanent power...

Open the catalog to page 9
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 10

Impulse Switch with integrated relay function ESR12NP ESR12NP-230V+UC © ® N L +C1 -C2 N L 1 NO contact not potential free 16A/250V AC. Incandescent lamp load up to 2300W. Off delay impulse switch with switch-off early warning and push-button permanent light switchable. Standby loss 0.5 watt only. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18 mm wide, 58 mm deep. Zero passage switching to protect contacts and lamps. This prolongs in particular the lifetime of energy saving lamps. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with...

Open the catalog to page 10
"Switchgear, power supply units and electronic energy meters" 2012, monitor presentation - 11

Digital settable Multifunction Impulse Swit with integrated rolay function ESai2DDX ELECTRONICS ESR12DDX-UC [ -m (D | J 5g[g |gg 3(L) 4 M fBl A2 HA14A31 3 -A2 24 +A3 (N) KL) 2 1+1 NO contacts potential free 16A/250V AC. Incandescent lamp load up to 2000W. Standby loss 0.03-0.4 watt only. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18 mm wide, 58 mm deep. With the patented Eltako Duplex technology (DX) the normally potential-free contacts can still switch in zero passage when switching 230V AC 50 Hz and therefore drastically reduce wear. Simply connect the neutral...