TWINFLOW STDL
14Pages

{{requestButtons}}

Catalog excerpts

TWINFLOW STDL - 2

TWINFLOW STDL Product Overview • 7 standard sizes from 125 mm to 500 mm • Air volume flow rates up to 1.74 m3/s • Static pressures up to 730 Pa • Suitable for operating temperatures up to +60°C • Redesigned casing to improve airflow and reduce specific fan powers • Acoustically lined internally to reduce breakout noise levels • Low Specific Fan Powers • Available in -C Twinflow STDL fans are suitable for external mounting. The range incorporates advanced backward curved impellers. Easy Installation All models are designed for direct connection to standard diameter flexible or rigid circular...

Open the catalog to page 2
TWINFLOW STDL - 3

TWINFLOW STDL Performance Range Curves 800 Elta Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request.

Open the catalog to page 3
TWINFLOW STDL - 4

Data provided is at standard air density of 1.2 kg/m3. ErP data in accordance with Regulation (EU) 1253/2014. Product category is NRVU. Measurement category used to determine energy efficiency: D. A variable speed drive is integrated within the fan. Peak Amps @ 230V / 1PH / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20pPa and is presented for comparative purposes only. Email info@eltauk.com Website eltauk.com

Open the catalog to page 4
TWINFLOW STDL - 5

Data provided is at standard air density of 1.2 kg/m3. ErP data in accordance with Regulation (EU) 1253/2014. Product category is NRVU. Measurement category used to determine energy efficiency: D. A variable speed drive is integrated within the fan. Peak Amps @ 230V / 1PH / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20pPa and is presented for comparative purposes only. Elta Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products...

Open the catalog to page 5
TWINFLOW STDL - 6

Data provided is at standard air density of 1.2 kg/m3. ErP data in accordance with Regulation (EU) 1253/2014. Product category is NRVU. Measurement category used to determine energy efficiency: D. A variable speed drive is integrated within the fan. Peak Amps @ 400V / 3PH / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20pPa and is presented for comparative purposes only. Email info@eltauk.com Website eltauk.com

Open the catalog to page 6
TWINFLOW STDL - 7

Data provided at standard air density of 1.2 kg/m3. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request.

Open the catalog to page 7
TWINFLOW STDL - 8

Data provided at standard air density of 1.2 kg/m3. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Email info@eltauk.com Website eltauk.com

Open the catalog to page 8
TWINFLOW STDL - 9

Data provided at standard air density of 1.2 kg/m3. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW. Elta Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request.

Open the catalog to page 9
TWINFLOW STDL - 10

Email info@eltauk.com Website eltauk.com Rectangular Spigot Version All dimensions are expressed in mm.

Open the catalog to page 10
TWINFLOW STDL - 11

‘Supplied as a single mount. Elta Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request.

Open the catalog to page 11
TWINFLOW STDL - 12

TWINFLOW STDL Email info@eltauk.com Website eltauk.com

Open the catalog to page 12
TWINFLOW STDL - 13

TWINFLOW STDL Elta Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request.

Open the catalog to page 13
TWINFLOW STDL - 14

Tel +44 (0) 1384 275800 Email info@eltauk.com eltauk.com STDL-08-2022 Issue D A member of HEVAC ASSOCIATION PATRONS

Open the catalog to page 14

All ELTA FANS catalogs and technical brochures

  1. VERSALINE VL

    8 Pages

  2. QUBE SQUHT

    14 Pages

  3. EKS

    69 Pages

  4. EKA

    16 Pages

  5. HIDEAWAY SH

    10 Pages

  6. VERSALINE VL

    8 Pages

  7. COMPACT SCD

    12 Pages

  8. COMPACT SCP

    20 Pages