ACH580-01/-31 The ACH580 drive sets new standards in both simplicity and reliability, and ensures smooth, energy-efficient operation of your HVAC systems in normal and mission-critical situations. ACH580-01, wall-mounted base drives The ACH580-01 wall-mounted drives are available from 1 to 100 HP at 208/240 V, 1 to 350 HP at 480 V, and 2 to 250 HP at 575 V. The ACH580-01 drives are available in UL (NEMA) Type 1 and 12 configurations. In standard installations, the drive is mounted directly onto a wall and uses the provided conduit box. Conduit openings are provided for bottom conduit entry & exit. For mounting in a customer-supplied cabinet, the conduit box may be removed. The ACH580-01 is a six-pulse drive that includes a 5% equivalent impedance for harmonic mitigation. The drive has a 100 kA SCCR rating when paired with appropriately sized upstream fuses. ACH580-31, ultra low harmonic wall-mounted base drives The ACH580-31 wall-mounted drives are available from 5 to 150 HP at 480 V. The ACH580-31 are available in UL (NEMA) Type 1 and 12 configurations. In standard installations, the drive is mounted directly onto a wall and uses the provided conduit box. Conduit openings are provided for bottom conduit entry and exit. For mounting in a customersupplied cabinet, the conduit plate may be removed. Features for HVAC The ACH580 comes standard with an intuitive control panel used to configure, control, and monitor the drive. An optional Bluetooth control panel allows the drive to configured via the control panel or the DriveTune app. A robust HVAC firmware package provides drive, motor, and application protection features. Examples of drive protection features include undervoltage, overvoltage, overcurrent, and ground fault protection. The ACH580 also has a variety of motor protection features including overload and stall protections. Application specific features, such as accepting four separate start interlocks (safeties), along with broken belt detection, are also included. The drive includes BACnet MS/TP, Modbus RTU, and Johnson N2 as standard. Additional protocols, such as BACnet/IP and LonWorks (coming 2019), are available with optional fieldbus adapters.

Open the catalog to page 1
ACH580-01/-31 - 2

Communication Protocols as standard (EIA-485): BACnet MS/TP, Modbus RTU, Johnson Controls N2 Available as plug-in options: BACnet/IP, Modbus TCP, PROFIBUS-DP, DeviceNet, EtherNet/IP, LonWorks (coming 2019) Application functions Start interlock Delayed start Run permissive (damper monitoring) Override operation mode Real-time clock (scheduling) PID controllers for motor and process Motor flying start Motor preheating Energy optimizer and calculators Timer 2 or 3 wire start/stop Ramp to stop 2 independent adjustable accel/decel ramp Protection functions Overvoltage controller Undervoltage...

Open the catalog to page 2
ACH580-01/-31 - 3

— Control panel features The ACH580 Assistant Control Panel features: • Intuitive to operate • Primary Setting menu to ease drive commissioning • Real-time clock • Diagnostic and maintenance functions • Full-graphic display, including chart, graph, and meter options • 21 editable home views • USB interface for PC and tool connection as standard • Parameters are alpha-numeric • North American version supports 14 languages as standard • Dedicated “Help” key • 4 user sets • Parameter are stored in control panel memory for later transfer to other drives or for backup of a particular system •...

Open the catalog to page 3
ACH580-01/-31 - 4

— Cable connections The following illustrations show the ACH580-01 and ACH580-31 cable connection points for the base drive. The illustrations indicate the location of input and output power connections as well as equipment and motor grounding connection points. ACH580 drives are configured for wiring access from the bottom only. At least three separate metallic conduits are required, one for input power, one for output power to the motor and one for control signals. BREAKERS MOTOR R+ T1/U T2/V T3/W RUDC+

Open the catalog to page 4
ACH580-01/-31 - 6

— Cable connections

Open the catalog to page 6
ACH580-01/-31 - 7

— Control connections Default I/O connections This is the default configuration of control connections for HVAC applications. 0...10 V DC speed reference signal Start/Stop signal Safety Run status Fault status Reference voltage and analog inputs and outputs SCR Signal cable shield (screen) AI1 Output frequency/speed reference: 0 to 10 V AGND Analog input circuit common +10V Reference voltage 10 V DC +10 V AI2 Actual feedback: 0 to 20 mA AGND Analog input circuit common AO1 Output frequency: 0 to 10 V AO2 Output current: 0 to 20 mA AGND Analog output circuit common Aux. voltage output and...