1. Catalogs
  2. Elogen
  3. PEM* ELECTROLYSERS

PEM* ELECTROLYSERS

PEM* ELECTROLYSERS

PEM* ELECTROLYSERS

Product catalog summary
Introduction
PEM Electrolysers offer a flexible and cost-effective solution for on-site hydrogen generation, ensuring reliability, ease of use, cleanliness, and safety.

Technical Specifications
  • Gas Production: Hydrogen output pressure up to 35 Barg with purity >99.9%; Oxygen output pressure 13 Barg with purity >99%.
  • Gas Purification System: Industrial purification with automatic regeneration, achieving H2 quality up to 99.999%.
  • Feeding Water: Conductivity <2000µS/cm, pressure 2 to 6 Bar, pH 4-10, temperature +5/+40°C, with integrated Reverse Osmosis and Electro De Ionisation systems.
  • Process Cooling Water: Max pressure 5 bar, input temperature +5°C to +45°C, quality includes bactericide, anticorrosive, and antifreezing fluid.
  • Installed Power: Voltage 400 V AC, frequency 50 Hz, stack consumption 4.4 kWh/Nm3 of H2.
  • Control System: Industrial SIL 2 PLC with a 15˝ color touch screen, supporting Modbus/Ethernet/analogic and serial communications.
  • Environmental & Operating Conditions: Storage and transport temperature +3 / +60°C, operating temperature +3 / +40°C, humidity 0 to 95% non-condensing.

Safety Norms & Regulations
Compliance with EC, PED, LVD, EMC directives, and ISO 22734-1, IEC 61508, IEC 62061 standards.

Product Line Specifications
  • Hydrogen production ranges from 5 to 120 Nm3/h across different models (E5 to E120).
  • Oxygen production ranges from 2.5 to 60 Nm3/h.
  • Feeding water consumption varies from <10 to <240 L/hr.
  • Process cooling water flow rate ranges from 1 to 24 m3/h.
  • Installed power ranges from 40 to 960 kVA, with system consumption decreasing from 5.7 to 4.8 kWh/Nm3 of H2.

Advantages
  • Efficiency: Stack efficiency over 80%, full system over 70%.
  • Safety: Environmentally friendly with ATEX electrical components.
  • Reliability: Operates 24/7 with a 20-year lifetime.
  • Simplicity: KOH free and cost-efficient.

Additional Features
Optional components available to meet specific customer requirements, with an indoor version offered.
See more

Catalog excerpts

PEM* ELECTROLYSERS-1

PEM* ELECTROLYSERS To d a y ’ s f l e x i b l e & c o s t e f f e c t i v e t e c h n o l o g y For a reliable, easy, clean and safe on site hydrogen generation PEM* : Proton Exchange Membrane STANDARD SUPPLY TECHNICAL SPECIFICATIONS Output pressure GAS PURIFICATION SYSTEM Industrial purification system with automatic regeneration based on deoxidizer & Temperature Swing Absorption Dryers H2 Quality FEEDING WATER (TAP WATER) Conductivity Water treatment Integrated Reverse Osmosis System (ROS) + Electro De Ionisation system PROCESS COOLING WATER Max pressure Input Temperature Bactericide, anticorrosive and antifreezing fluid INSTALLED POWER Voltage Stack consumption Industrial SIL 2 PLC with analogic and digital I/O modules associated to a 15˝ color tactile screen; Process can be controlled by input of : H2 flow, pressure, available power Modbus / Ethernet / analogic and serial communications; modular communication interface for easy add-on capability; others : on demand ENVIRONMENTAL & OPERATING CONDITIONS Storage & Transport temperature Operating temperature Provided from a non-hazardous area SAFETY NORMS & REGULATIONS Compliance EC Compliance - Machinery 2006/42/EC PED 97/23/EC - LVD 2006/95/EC - EMC 2004/108/EC Our equipments comply with major gas companies expectations

 Open the catalog to page 1
PEM* ELECTROLYSERS-2

Today's flexible & cost effective technology PRODUCT LINE SPECIFICATIONS HYDROGEN PRODUCTION OXYGEN PRODUCTION FEEDING WATER PROCESS COOLING WATER INSTALLED POWER Fully integrated outdoor unit and user friendly interface AREVA H2GEN OFFERS A WIDE SELECTION OF OPTIONAL COMPONENTS TO MEET CUSTOMER SPECIFIC REQUIREMENTS Environmental friendly. All electrical components ATEX Full system over 70% Cost efficient 8, avenue du Parana, 91940 Les Ulis

 Open the catalog to page 2

All Elogen catalogs and technical brochures

  1. ELYTE 260

    2  Pages

  2. ELYTE 200

    2  Pages

  3. ELYTE 50

    2  Pages

  4. ELYTE 10

    2  Pages

Archived catalogs

  1. E40

    2  Pages

  2. E20

    2  Pages

  3. Leaflet CETH2

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.