Group: GTT
Catalog excerpts
PROTON EXCHANGE MEMBRANE Purity without additional purification Hydrogen Purification System Industrial purification system with automatic regeneration. The hydrogen purity according to ISO 14687-2 for the use in fuel cell vehicles is met. Max. hydrogen purity Feeding Water (Tap Water) Water quality acc. Water treatment Integrated Reverse Osmosis System (ROS) + electro de-ionisation system Power Input Voltage From 400 V AC to high voltage, alternatively a transformer can be included Safety Norms and Regulations Compliance 8 Avenue du Parana | 91940 Les Ulis| France | Tel. +33 181 871 240 contact@elogenh2.com Machine directive 2006/42/CE Pressurised equipment directive 2014/68/UE Low voltage directive 2014/35/UE Electromagnetic compatibility directive 2014/30/UE ATEX directive 2014/34/UE CE Mark Eupener Straße 165 | 50933 Köln | Germany | Tel. +49 221 291 907 30 info@elogenh2.com
Open the catalog to page 1Specification Hydrogen Production H2 flow rate [Nm3/h] Oxygen Production O2 flow rate [Nm3/h] Operating range Hydrogen production [%] Power input [%] Feeding Water Consumption [l/Nm3 H2] Installed Power Electrolysis [kW] Power [kVA] Specific Energy consumption Stack consumption [kWh/Nm3 H2] System consumption [kWh/Nm3 H2] Footprint Dimensions 8 Avenue du Parana | 91940 Les Ulis| France | Tel. +33 181 871 240 contact@elogenh2.com Eupener Straße 165 | 50933 Köln | Germany | Tel. +49 221 291 907 30 info@elogenh2.com