1. Catalogs
  2. Elogen
  3. Multi MW Systems

Multi MW Systems

Multi MW Systems

Multi MW Systems

Product catalog summary
Specifications
  • Gas Production: Hydrogen and Oxygen with maximum output pressures of 30 barg and 14 barg respectively.
  • Purity: Hydrogen purity exceeds 99.9% without additional purification, while oxygen purity exceeds 97%.
  • Power Input: Voltage ranges from 400 V AC to high voltage, with an optional transformer. Frequency is 50 Hz.
  • Hydrogen Purification System: Includes an industrial purification system with automatic regeneration, achieving a maximum hydrogen purity of 99.999% as per ISO 14687-2 standards for fuel cell vehicles.
  • Feeding Water: Tap water with quality according to 98/83/EG, pressure between 2 to 6 bar, pH between 4 to 10, and temperature from +5 to +35 °C. Integrated Reverse Osmosis System (ROS) and electro de-ionisation system for water treatment.
Safety Norms and Regulations
  • Compliance with Machine directive 2006/42/CE, Pressurised equipment directive 2014/68/UE, Low voltage directive 2014/35/UE, Electromagnetic compatibility directive 2014/30/UE, and ATEX directive 2014/34/UE.
  • CE Mark certified.
Production Capacities
  • Hydrogen Production: Minimum flow rate of 2,000 Nm3/h.
  • Oxygen Production: Minimum flow rate of 1,000 Nm3/h.
Operating Range
  • Hydrogen production and power input range from 0.1% to 100%.
Feeding Water Consumption
  • Less than 2 liters per Nm3 of hydrogen produced.
Installed Power
  • Electrolysis requires a minimum of 10,000 kW, and power requires a minimum of 13,000 kVA.
Specific Energy Consumption
  • Stack consumption is 4.3 kWh/Nm3 H2, and system consumption is 4.8 kWh/Nm3 H2.
Footprint
  • Dimensions are less than 31.25 m2/MWel.
See more

Catalog excerpts

Multi MW Systems-1

PROTON EXCHANGE MEMBRANE Purity without additional purification Hydrogen Purification System Industrial purification system with automatic regeneration. The hydrogen purity according to ISO 14687-2 for the use in fuel cell vehicles is met. Max. hydrogen purity Feeding Water (Tap Water) Water quality acc. Water treatment Integrated Reverse Osmosis System (ROS) + electro de-ionisation system Power Input Voltage From 400 V AC to high voltage, alternatively a transformer can be included Safety Norms and Regulations Compliance 8 Avenue du Parana | 91940 Les Ulis| France | Tel. +33 181 871 240 [email protected] Machine directive 2006/42/CE Pressurised equipment directive 2014/68/UE Low voltage directive 2014/35/UE Electromagnetic compatibility directive 2014/30/UE ATEX directive 2014/34/UE CE Mark Eupener Straße 165 | 50933 Köln | Germany | Tel. +49 221 291 907 30 [email protected]

 Open the catalog to page 1
Multi MW Systems-2

Specification Hydrogen Production H2 flow rate [Nm3/h] Oxygen Production O2 flow rate [Nm3/h] Operating range Hydrogen production [%] Power input [%] Feeding Water Consumption [l/Nm3 H2] Installed Power Electrolysis [kW] Power [kVA] Specific Energy consumption Stack consumption [kWh/Nm3 H2] System consumption [kWh/Nm3 H2] Footprint Dimensions 8 Avenue du Parana | 91940 Les Ulis| France | Tel. +33 181 871 240 [email protected] Eupener Straße 165 | 50933 Köln | Germany | Tel. +49 221 291 907 30 [email protected]

 Open the catalog to page 2

All Elogen catalogs and technical brochures

  1. ELYTE 260

    2  Pages

  2. ELYTE 200

    2  Pages

  3. ELYTE 50

    2  Pages

  4. ELYTE 10

    2  Pages

Archived catalogs

  1. E40

    2  Pages

  2. E20

    2  Pages

  3. Leaflet CETH2

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.