ELYTE 200

ELYTE 200

ELYTE 200

Product catalog summary
Specifications
The document outlines the specifications for a Proton Exchange Membrane system used for gas production, specifically hydrogen and oxygen. The maximum output pressure for hydrogen is 30 barg and for oxygen is 14 barg. The purity levels without additional purification are >99.9% for hydrogen and >97% for oxygen. The system operates on a voltage range from 400 V AC to high voltage, with a frequency of 50 Hz. An industrial purification system ensures hydrogen purity meets ISO 14687-2 standards, achieving a maximum purity of 99.999%.
Feeding Water Requirements
The system uses tap water with quality according to 98/83/EG, requiring a pressure of 2 to 6 bar, pH between 4 to 10, and temperature from +5 to +35 °C. It includes an integrated Reverse Osmosis System (ROS) and electro de-ionisation system for water treatment.
Safety Norms and Regulations
Compliance with several directives is noted, including the Machine Directive 2006/42/CE, Pressurised Equipment Directive 2014/68/UE, Low Voltage Directive 2014/35/UE, Electromagnetic Compatibility Directive 2014/30/UE, and ATEX Directive 2014/34/UE. The system is CE marked.
Production Capacities
The hydrogen production flow rate is 200 Nm3/h, and the oxygen production flow rate is 100 Nm3/h. The operating range for both hydrogen production and power input is 2.5-100%.
Water and Power Consumption
Water consumption is less than 2 liters per Nm3 of hydrogen produced. The installed power for electrolysis is 1,000 kW, with a total power requirement of 1,240 kVA. Specific energy consumption is 4.3 kWh/Nm3 H2 for stack consumption and 4.9 kWh/Nm3 H2 for system consumption.
See more

Catalog excerpts

ELYTE 200-1

PROTON EXCHANGE MEMBRANE Purity without additional purification Hydrogen Purification System Industrial purification system with automatic regeneration. The hydrogen purity according to ISO 14687-2 for the use in fuel cell vehicles is met. Max. hydrogen purity Feeding Water (Tap Water) Water quality acc. Water treatment Integrated Reverse Osmosis System (ROS) + electro de-ionisation system Power Input Voltage From 400 V AC to high voltage, alternatively a transformer can be included Safety Norms and Regulations Compliance 8 Avenue du Parana | 91940 Les Ulis| France | Tel. +33 181 871 240 [email protected] Machine directive 2006/42/CE Pressurised equipment directive 2014/68/UE Low voltage directive 2014/35/UE Electromagnetic compatibility directive 2014/30/UE ATEX directive 2014/34/UE CE Mark Eupener Straße 165 | 50933 Köln | Germany | Tel. +49 221 291 907 30 [email protected]

 Open the catalog to page 1
ELYTE 200-2

Specification Hydrogen Production H2 flow rate [Nm3/h] Oxygen Production O2 flow rate [Nm3/h] Operating range Hydrogen production [%] Power input [%] Feeding Water Consumption [l/Nm3 H2] Installed Power Electrolysis [kW] Power [kVA] Specific Energy consumption Stack consumption [kWh/Nm3 H2] System consumption [kWh/Nm3 H2] 8 Avenue du Parana | 91940 Les Ulis| France | Tel. +33 181 871 240 [email protected] Eupener Straße 165 | 50933 Köln | Germany | Tel. +49 221 291 907 30 [email protected]

 Open the catalog to page 2

All Elogen catalogs and technical brochures

  1. ELYTE 260

    2  Pages

  2. ELYTE 50

    2  Pages

  3. ELYTE 10

    2  Pages

Archived catalogs

  1. E40

    2  Pages

  2. E20

    2  Pages

  3. Leaflet CETH2

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.