E20-1

Hydrogen on demand 20 10 15 5 E E E PEM Electrolyser 20 Nm 3 /h PEM Electrolyser FOR A RELIABLE, EASY, CLEAN AND SAFE ON SITE HYDROGEN GENERATION • • Modular architecture based on a 10 Nm3/h production capacity stack 14 Bar H 2 Output pressure Gas purity from 99.9 to 99.999% Tactile control panel • • Advantages Safety : Physical separation of the H2 and O2 production Efficiency : The current density on PEM electrolyzers can reach more than 1 A/cm2 Reliability : Progressive and discontinuous operation possible Simplicity : Reduced maintenance and autonomous working process PEM Electrolysers : A Product Line from 5 to 160 Nm3/h 5 / 10 E E 20 E 30 E 40 E

 Open the catalog to page 1
E20-2

Te c h n i c a l S p e c i f i c a t i o n s Standard Supply Hydrogen Production Flow Rate Output pressure Purity Output connection Feeding water Consumption Pressure Temperature Quality Input connection Installed Power Power Voltage Frequency System Consumption Control System MPC Nm3/h 20 14 Barg > 99.9 % H2 & Drain H2 : G3/8 < 40 l/h 3 to 6 Bar < 35°C Tap water To be specified Communication Dimensions & Weight Gas Skid Rectifier PLC Environmental & Operating conditions Storage & Transport temperature 3 - 60°C Operating temperature 3 - 40°C Safety Norms & Regulations Compliance O ptions Gas...

 Open the catalog to page 2

All Elogen catalogs and technical brochures

  1. ELYTE 260

    2  Pages

  2. ELYTE 200

    2  Pages

  3. ELYTE 50

    2  Pages

  4. ELYTE 10

    2  Pages

Archived catalogs

  1. E40

    2  Pages

  2. Leaflet CETH2

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.