Electromechanical components T-S ERIE S [ REDEFINING STANDARD ]

 Open the catalog to page 1
Outdoor air conditionners Tseries-2

INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 UR/cUR Recognized_ UR/cUR recognized on select models, reference performance data tables. CE EAC Telcordia GR-487 capable C €•<£>■**!.. ER[ LISTED APPLICATION • Industrial automation • Telecommunications equipment • Package handling equipment • Security and defense systems • And more • Painted galvanized sheet-metal cover for rugged factory and outdoor environments • Easy-mount flanges for simple installation • Every unit functionally tested before shipping SPECIFICATIONS • Models for 115, 230 and 460 VAC power input •...

 Open the catalog to page 2
Outdoor air conditionners Tseries-3

^ElMEKO Electromechanical components PERFORMANCE DATA T15 800 BTU/HR. (234 WATT) MODELS Item number Outdoor Model without Heat Pkg. T150116G100 T150126G100 Outdoor Model with Heat Pkg. Outdoor Model/SST/Corrosion/4X Outdoor Model/SST/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watt At 131 °F/131 °F (55 °C/55 °C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 °F/95 °F (35 °C/35 °C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External...

 Open the catalog to page 3
Outdoor air conditionners Tseries-4

Electromechanical components Performance Curves for T15 Models 800 BTU/Hr. (234 Watt) Cooling Capacity (BTU/Hr.) T15-01x6-Gxxx Capacity Curves 50 Hz Ambient Air In (°C) 40 Cooling Capacity (BTU/Hr.) SUBJECT TO CHANGE WITHOUT NOTIC

 Open the catalog to page 4
Outdoor air conditionners Tseries-5

Electromechanical components SUBJECT TO CHANGE WITHOUT NOTICE

 Open the catalog to page 5
Outdoor air conditionners Tseries-6

Electromechanical components PERFORMANCE DATA T20 2000 BTU/HR. (586 WATT) MODELS Item number Outdoor Model without Heat Pkg. T200216G100 T200226G100 T200246G400 Outdoor Model with Heat Pkg. T200216G150 T200226G150 - Outdoor Model/SS/Corrosion/4X Outdoor Model/SS/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watt At 131 °F/131 °F (55 °C/55 °C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 °F/95 °F (35 °C/35 °C): BTU/Hr. (50/60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal...

 Open the catalog to page 6
Outdoor air conditionners Tseries-7

Electromechanical components Performance Curves for T20 Models 2000 BTU/Hr. (586 Watt) T200216Gxxx Capacity Curves at 50hz Hz Ambient Air In (°C) 20 Cooling Capacity (BTU/Hr) T200216Gxxx Capacity Curves at 60Hz Ambient Air In (°C) 20 Cooling Capacity (BTU/Hr) SUBJECT TO CHANGE WITHOUT NOTICE

 Open the catalog to page 7
Outdoor air conditionners Tseries-8

Electromechanical components Performance Curves for T20 Models 2000 BTU/Hr. (586 Watt) T200226Gxxx Capacity Curves at 50 Hz Ambient Air In (°C) 20 Cooling Capacity (BTU/Hr) T200226Gxxx Capacity Curves at 60 Hz Ambient Air In (°C) 40 Cooling Capacity (BTU/Hr) SUBJECT TO CHANGE WITHOUT NOTIC

 Open the catalog to page 8
Outdoor air conditionners Tseries-9

^ElMEKO Electromechanical components MOUNTING HARDWARE FOR FULLY RECESSED MOUNTING IS BEHIND REMOVABLE FRONT COVER. CLEANABLE, REUSABLE ALUMINUM INLET FILTER SLIDES OUT SLOT IN BOTTOM OF FRONT COVER. NOTE: 1. MOUNTING GASKET SUPPLIED (NOT SHOWN) 2. UNITS: in. [mm] Cutout Dimensions (Externally Mounted) Cutout Dimensions (Internally Mounted) SUBJECT TO CHANGE WITHOUT NOTICE

 Open the catalog to page 9
Outdoor air conditionners Tseries-10

^ElMEKO Electromechanical components INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 UR/cUR Recognized UR/cUR recognized on select models, reference performance data tables. CE EAC Telcordia GR-487 capable CO©“c*IusfH[ LISTED APPLICATION • Industrial automation • Telecommunications equipment • Package handling equipment • Security and defense systems • And more SCOPE OF DELIVERY • Air conditioner unit • Mounting gasket and hardware kit • Cutout template • Installation instruction • Compact footprint to minimize real estate and maximize capacity • Reliable mechanical...

 Open the catalog to page 10
Outdoor air conditionners Tseries-11

^ElMEKO Electromechanical components PERFORMANCE DATA T29 4000 BTU/HR. (1173 WATT) MODELS Item number Outdoor Model without Heat Pkg. T290416G100 T290426G100 Outdoor Model with Heat Pkg. T290416G150 T290426G150 Outdoor Model/SS/Corrosion/4X Outdoor Model/SS/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watt At 131 °F/131 °F (55 °C/55 °C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 °F/95 °F (35 °C/35 °C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal...

 Open the catalog to page 11
Outdoor air conditionners Tseries-12

Electromechanical components Performance Curves for T29 Models 4000 BTU/Hr. (1173 Watt) T29-04x6-Gxxx Capacity Curves 50 Hz 20 Cooling Capacity (BTU/Hr.) Cooling Capacity (BTU/Hr.) SUBJECT TO CHANGE WITHOUT NOTIC

 Open the catalog to page 12
Outdoor air conditionners Tseries-13

^ElMEKO Electromechanical components MOUNTING HARDWARE FOR FULLY RECESSED MOUNTING IS BEHIND REMOVABLE FRONT COVER. CLEANABLE, REUSABLE ALUMINUM INLET FILTER SLIDES OUT SLOT IN BOTTOM OF FRON T COVER. -DRAIN STUB 1/4-20 MOUNTING HOLES (16X) (8 ON BACK FACE, 8 BEHIND FRONT COVER) NOTE: 1. MOUNTING GASKET SUPPLIED (NOT SHOWN) 2. UNITS: in. [mm] Cutout Dimensions (Externally Mounted) Cutout Dimensions (Internally Mounted) SUBJECT TO CHANGE WITHOUT NOTICE T-SERIES 13

 Open the catalog to page 13
Outdoor air conditionners Tseries-14

^ElMEKO Electromechanical components PERFORMANCE DATA T43 6000 BTU/HR. (1758 WATT) MODELS 14 T-SERIES SUBJECT TO CHANGE WITHOUT NOTICE

 Open the catalog to page 14
Outdoor air conditionners Tseries-15

Electromechanical components Performance Curves for T43 Models 6000 BTU/Hr. (1758 Watt) T43-06X6-G150 Capacity Curves 50 Hz 20 Cooling Capacity (BTU/Hr.) Cooling Capacity (BTU/Hr.) SUBJECT TO CHANGE WITHOUT NOTICE

 Open the catalog to page 15
Outdoor air conditionners Tseries-16

^ElMEKO Electromechanical components PERFORMANCE DATA T43 8000 BTU/HR. (2344 WATT) MODELS 16 T-SERIES SUBJECT TO CHANGE WITHOUT NOTICE

 Open the catalog to page 16
Outdoor air conditionners Tseries-17

Electromechanical components Performance Curves for T43 Models 8000 BTU/Hr. (2344 Watt) T43-08X6-G150 Capacity Curves 50 Hz 20 Cooling Capacity (BTU/Hr.) 10000 Cooling Capacity (BTU/Hr.) SUBJECT TO CHANGE WITHOUT NOTICE

 Open the catalog to page 17
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.