AUDIO SOLUTION REMOTE AUDIO PLUS Product description MAIN FEATURES IR CONTROLLED MOTOR DRIVER KIT FOR ELMA’S TYPE A4, A47 AND 04 SWITCHES › › › › › › REMOTE AUDIO PLUS IR remote controlled with IR teach-in function Adjustable to different switch types Push button and host control remote options Relay mute function Zero EMI emission when not actuated Switch feel virtually not affected by motor (LIN motor option) Customer supplies their own remote Note torque limits per motor type REMOTE AUDIO PLUS with LIN motor 11/65/EU) Remote Audio Plus with LIN motor Standard version with standard motor High-end audio and Pro audio Industrial controls STANDARD VERSION with standard motor * Switch and IR remote unit are not included

Open the catalog to page 1
Remote Audio Plus_Datasheet_E - 2

AUDIO SOLUTION REMOTE AUDIO PLUS ELMA Your Solution Partner Dimensions, pin assignment and circuit diagramSWITCH DESIGN PIN ASSIGNMENT CONTROL MODULE IR RECEIVER Solder jumper ♦12VDC Power Gno input DC motor output 23 (oreen) 2A (btack) Stepper I a (btuel motor 18 (red) t/otor tor due adjustment (C.w. increasing torque) CIRCUIT DIAGRAM FOR RELAY MUTE FUNCTION In Out GND In Out GND Dimensions in mm Tolerances according to DIN ISO 2768-1 (m), unless otherwise specified

Open the catalog to page 2
Remote Audio Plus_Datasheet_E - 3

AUDIO SOLUTION REMOTE AUDIO PLUS Assembling the kit 1. ount the two 30 mm stand-offs to the stepper motor M using the two set screws (do not tighten the set screws). 2. Feed the switch drive linkage onto the shaft of the stepper motor (do not tighten). 3. ssemble the stepper motor with its stand-offs and the linA kage onto the control module using the two M3 screws (be careful when feeding the linkage through the position sensor in the middle of the control module). 4. wist together the stepper motor’s wires (blue with red, T green with black) and solder them to the control module (see pin...

Open the catalog to page 3
Remote Audio Plus_Datasheet_E - 4

AUDIO SOLUTION REMOTE AUDIO PLUS ELMA Your Solution Partner End stop calibration and IR teach-in USING THE TACT SWITCH 1. Push the tact switch until the LED flashes for approximately 1 second. 2. Turn the switch to the fully right position and quickly push the tact switch. The LED flashes for approximately 300 milliseconds for confirmation. 3. Turn the switch to the fully left position and quickly | long push the tact switch. Quick push: The LED flashes for approximately 300 milliseconds for confirmation. Long push: Jumping to #5 (used when no IR receiver connected, e.g. in slave mode). 4....

Open the catalog to page 4
Remote Audio Plus_Datasheet_E - 5

AUDIO SOLUTION REMOTE AUDIO PLUS #1 CLASSIC SINGLE Auf UNIT OPERATION Ab 12 RAPLUS The classic mode of300 mm operationVDC Versorgung a single unit incorporates Max. 12 IR in VDC Versorgung that is either manually or IR controlled. The versatile control +12 GND GND IR Auf Vcc +12 GND module can be adjusted to individual end stop positions, Ab RAPLUS switch resolutions and operating speeds. Any type of NEC Max. 300 mm RAPLUS IR in compliant IR protocol can be used and «taught in». The GND IR Vcc power requirements are 12 VDC nominal at 1.2 A (2.4 A GND SER with LIN motor) peak current VDC...

Open the catalog to page 5
Remote Audio Plus_Datasheet_E - 6

Keep GND wire short, use >= 0.25 mm 2 (AWG23) RAPLUS Slave-Einheit (rechts) AUDIO SOLUTION RAPLUS REMOTE AUDIO PLUS Master-Einheit Max. 300 mm Application examples Aktiviere Löt-Brücke Bei Master-Einheit! RAPLUS Master unit IR in (left) RAPLUS Slave unit (right) Activate soldering jumper at master unit! #4 PUSH BUTTON CONTROL 12 VDC Versorgung The unit can also be controlled by separate up and down buttons instead of turning theAuf rotary switch manually. This +12 GND PB Aufauf way the assembled RAPLUSAb switch combination does not / PB ab Ab RAPLUS need to be attached to the front panel,...

Open the catalog to page 6
Remote Audio Plus_Datasheet_E - 7

AUDIO SOLUTION REMOTE AUDIO PLUS ELMA Your Solution Partner Specifications CONTROL MODULE Operating voltage: Current consumption: 5 VDC output: Switch torque capacity: Indexing resolution: SER interface: 8 to 15 VDC (12 VDC nominal) Standard motor: max. 1.2 A peak2 max. 20 mA stand-by (at 12 VDC, no motor operation, without display module) Regulated, max. 100 mA load Standard motor: max. 6 Ncm | LIN motor: max. 10 Ncm (limitable by trim pot, at 12 VDC) 12, 24 or 48 (47) positions Single pulse PPM (low-active): «up» 500 ps | «down» 1 ms | «mute on» 2 ms | «mute off» 4 ms (all ±20 %) Single...

Open the catalog to page 7

All Elma Electronic AG catalogs and technical brochures

  1. Railway

    32 Pages

  2. Elma bustronic

    68 Pages

  3. PICMG

    136 Pages

  4. FLEXCOM

    4 Pages

  5. Defense

    44 Pages

  6. VITA Catalog

    93 Pages

  7. 9289 XMCStor

    2 Pages

Archived catalogs

  1. MicroTCA

    12 Pages

  2. mtca4

    12 Pages