Fittings & Accessories
32Pages

{{requestButtons}}

Catalog excerpts

Fittings & Accessories - 1

Fittings & Accessories Fittings & Accessories for accurate measurements

Open the catalog to page 1
Fittings & Accessories - 2

GLK20050C005/GLJ25050C005 - for platic ampoules & syringe barrels...

Open the catalog to page 2
Fittings & Accessories - 5

Fittings, Accessories & Spare parts GKJ Packing Gland Normal & vacuum sealed cans and glass jars. Packing Glands for Probes 1.2 mm Stainless steel tube Type Description Ordering code No.

Open the catalog to page 5
Fittings & Accessories - 6

TPJ Packing Gland Stainless steel frame for plastic & aluminium doypacks and flatpouches. Packing Glands for Probes 1.2 mm Type Description Ordering code No.

Open the catalog to page 6
Fittings & Accessories - 7

GEJ Packing Gland Packing gland for small plastic and aluminium containers. Packing Glands for Probes 1.2 mm Type Description Ordering code No. Packing Glands for Loggers 2 mm Type Fitting Ordering code No. Spare Parts Type Description Ordering code No. TEJ21080C037 Pouch Fixture Packing gland for pouches. Packing Gland for Probes & Loggers Type Description Ordering code No.

Open the catalog to page 7
Fittings & Accessories - 8

RECART Packing Gland Packing gland for retortable cartons. Packing Gland for Probes 1.2 mm and square boxes/bricks 82 mm. Type Description Ordering code No. HBJ-Q Packing gland Packing gland for all kind of ravioli pieces. The packing gland and can also be used for meat balls, chunks, fish etc., in sterilization, pasteurization, cooling and freezing. Packing Gland for Probes & Loggers Type Description Ordering code No.

Open the catalog to page 8
Fittings & Accessories - 9

HBJ-120 Packing Gland Packing gland for all kind of sausages in sterilization, pasteurization, cooling and freezing. Packing Gland for Probes & Loggers Type Description Ordering code No. HBK70000Q Packing Gland Packing gland for all kind of shrimps in sterilization, pasteurization, cooling and freezing. Packing Gland for Probes & Loggers Type Description Ordering code No. Fixture for Shrimps with protection

Open the catalog to page 9
Fittings & Accessories - 10

Feed Through - For STC thermocouples Supports up to 40 thermocouples sensors and pressure sensor. Description Ordering code No.

Open the catalog to page 10
Fittings & Accessories - 11

Rubber Packings - For STC thermocouples (PTFE cables) Hole diameter: 2 mm Type Description Ordering code No.

Open the catalog to page 11
Fittings & Accessories - 12

Spare Parts for TSK/TSJ Packing Gland Type Description Ordering code No.

Open the catalog to page 12
Fittings & Accessories - 13

PAJ Pro Pressure Packing Gland External mounting in vials and bottles. Type Description Ordering code No.

Open the catalog to page 13
Fittings & Accessories - 14

GLK20050C005/ GLJ25050C005 Packing gland for plastic ampoules and syringe barrels with cone. Packing Glands for Probes 1.2 mm & for loggers 2 mm Type Description Ordering code No.

Open the catalog to page 14
Fittings & Accessories - 15

GVK Packing Gland Packing gland for glass and plastic bottles. Packing Gland for Probes 1,2 mm and Loggers 2-3 mm Type Description Ordering code No.

Open the catalog to page 15
Fittings & Accessories - 16

Packing glands for vials Packing gland for vials and lyophilization processes. Packing Glands for flex sensors 01.8 Type Description Ordering code No.

Open the catalog to page 16
Fittings & Accessories - 17

Wall Contact Puck Packing gland for measuring surface temperature. 1 Type Description Ordering code

Open the catalog to page 17
Fittings & Accessories - 18

FIXPRO Case Fixation and protection case in soft silicone material for TSP loggers. Type Description Ordering code No.

Open the catalog to page 18
Fittings & Accessories - 19

ID labels for thermocouples Type Description Ordering code No. Thermal Barriers Special Thermal barrier in PTFE. Description Ordering code PTFE Thermal Barrier 25901507

Open the catalog to page 19
Fittings & Accessories - 20

Thermal Barriers Type Description Ordering code No.

Open the catalog to page 20
Fittings & Accessories - 21

Tools TC89 Can Punch Can punch for all kinds of containers. Type Description Ordering code No.

Open the catalog to page 21
Fittings & Accessories - 22

TC42 Cutting tool Cutting tool for plastic containers 08 mm. Type Description Ordering code No.

Open the catalog to page 22
Fittings & Accessories - 23

Spare Parts Space bar in PEEK Type Description Ordering code No.

Open the catalog to page 23
Fittings & Accessories - 24

Accessory box Type Description Ordering codes No.

Open the catalog to page 24
Fittings & Accessories - 25

Logger Tray Type Description Ordering code No.

Open the catalog to page 25
Fittings & Accessories - 26

Batteries TSP/Compact/Frigo Type Description Ordering code No.

Open the catalog to page 26
Fittings & Accessories - 27

Suitcases / Flightcases Type Description Dimensions Ordering code No.

Open the catalog to page 27
Fittings & Accessories - 28

Type Description Dimensions Ordering code No.

Open the catalog to page 28
Fittings & Accessories - 29

Type Description Dimensions Ordering code No.

Open the catalog to page 29
Fittings & Accessories - 30

Calculation of sensor, gland & space bar specifications C=47 mm D=10 mm A=37 mm B=42 mm The picture shows an example of how to calculate the measuring depth for various types of containers. The measuring depth in which the measuring point - “cold spot” has to be determined. In this case, the cold spot is 37 mm from the lid. The packing gland has to be 5 mm longer than the measuring depth, corresponding to the size of the sealings of the gland and the sensor. The length of the gland is specified in the last three characters of the type designation - GKJ-21009C-042. In this case, the sensor...

Open the catalog to page 30
Fittings & Accessories - 31

Calculation of thermocouple & gland specifications C=76 mm B=57 mm A=51 mm Ø2 GKJ-13009C-057 The picture shows an example of how to calculate the measuring depth for all kinds of containers. The measuring depth in which the measuring point - “cold spot” has to be situated. The packing gland has to be 6 mm longer than the measuring depth, corresponding to the size of the sealings of the gland and the probe. The length of the gland is specified in the last three characters of the type designation - GKJ-13009C-057. In this case, the probe electrode length is 80 mm, specified in the last three...

Open the catalog to page 31
Fittings & Accessories - 32

Since the late 1940’s Ellab A/S has been a leading manufacturer of process validation and monitoring systems used in the food, medical device and pharmaceutical industries. Calibration Certifications and Service Ellab maintains a complete calibration facility for annual certifications and service. Ellab A/S temperature, resistance, pressure and humidity calibration laboratory is accredited according to ISO 17025 by DANAK under registration no. 520. Service and maintenance contracts are available. Rental & Demos Demo systems are available for trial and rental. Please contact your local Ellab...

Open the catalog to page 32

All Ellab Validation & Monitoring Solutions catalogs and technical brochures

  1. SteriSense®

    8 Pages

  2. E-Val™ Pro

    16 Pages