video corpo

Wired (BUS) electro-installation
100Pages

{{requestButtons}}

Catalog excerpts

Wired (BUS) electro-installation - 1

TECHNICAL CATALOGUE

Open the catalog to page 1
Wired (BUS) electro-installation - 2

We are traditional, innovative and purely Czech development manufacturer of electronic devices and we have been your partner in the field of electroinstallations for 26 years. ELKO EP employs about 330 people, exports its products to more than seventy countries, and has representatives in thirteen foreign branches. Company of the Year of the Zlín Region, Visionary of the Year, Global Exporter of the Year, Participation in the Czech TOP 100, these are just some of the awards received. Still, we are not finnished. We are constantly striving to move forward in the field of innovation and...

Open the catalog to page 2
Wired (BUS) electro-installation - 3

ANNUAL TURNOVER iNELS INSTALLATION 13 BRANCHES OVER THE WORLDS EXPORTING COUNTRIES modern antistatic personal access to more more than 30 engineers spaces, 2x fully auto- than 70 sales representa- vide technical support tives in ELKO EP Holding production lines, existing products provides impeccable services and superior products at an affordable price.

Open the catalog to page 3
Wired (BUS) electro-installation - 4

Choose the right one! WIRELESS ELECTRICAL INSTALLATIONS If you are going to renovate the house but, you do not want to interfere with the existing wiring, take advantage of our wireless solutions. The communication between the components works wirelessly at 868-916 MHz, using our unique RFIO and RFIO2 protocols. Both are proprietary ELKO EP wireless protocols , which have a completely unique structure. Are you building a new house? Then you should consider a BUSbased solution. A BUS in this sense is a data conductor that is distributed in the walls across the entire home. As opposed to a...

Open the catalog to page 4
Wired (BUS) electro-installation - 5

BUS electro-installation The BUS electro installation iNELS BUS System is a unique solution for electrical installation in the implementation of new projects of houses, villas, apartment buildings, office buildings, hotels, restaurants, wellness centres or perhaps even warehouse or production hall. The ability to deploy this solution in such a wide variety of different buildings with various purposes and uses lies in its modularity. Thanks to the modular design, the system is very flexible and allows on the one hand, a solution of single-purpose tasks such as control of lighting in...

Open the catalog to page 5
Wired (BUS) electro-installation - 6

Catalogue content

Open the catalog to page 6
Wired (BUS) electro-installation - 7

Catalogue content

Open the catalog to page 7
Wired (BUS) electro-installation - 8

CU3-01M Central unit Switching actuators CU3-02M Central unit JA3-02B/DC Shutter actuator Converters JA3-018M Shutter Actuator, 18-channel ADC3-60M Analog-digital converter Input units FA3-612M Fan Coil Control Actuator IM3-20B Binary input units Binary input units Binary input units

Open the catalog to page 8
Wired (BUS) electro-installation - 9

MI3-02M/ETH External master BUS with Ethernet communication BPS3-01M BPS3-02M BUS separator from power supply LBC3-02M Dimming actuator for electronic ballasts, 2-channel DCDA-33M Dimming actuator for LED sources, 3-channel RFDA-73M/RGB Dimming actuator for LED (RGB) strips, 3-channel EMDC-64M Gateway iNELS - DALI/DMX DMD3-1 Combined motion and light intensity detector

Open the catalog to page 9
Wired (BUS) electro-installation - 10

Overview of system units Wall units and controllers GGGG GGGG EST3 GSB3-40 Elko smart touch screen Glass switch button GSB3-60 Glass switch button GSB3-80 Glass switch button IDRT3-1 Digital room thermo-regulator Hotel solutions CU3-04M Central unit GCR3-11 Glass card reader GDB3-10 Glass door bell GBP3-60L/2F Glass bedside panel, left GBP3-60R/2F Glass bedside panel, right GBP3-60L/1F Glass bedside panel, left GBP3-60R/1F Glass bedside panel, right

Open the catalog to page 10
Wired (BUS) electro-installation - 11

WMR3-21 Wall card reader Glass wall card reader EHT3 GRT3-50 Elko Hotel Touch screen Glass room thermo-regulator GSP3-100 Glass switch panel GSB3-20/S Glass switch button with symbols GSB3-40/S Glass switch button with symbols GSB3-60/S Glass switch button with symbols

Open the catalog to page 11
Wired (BUS) electro-installation - 12

Overview of system units Multimedia Radio NOW PLAYING: Radio LARA Radio LARA Intercom Connection Server iNELS Touch Panel 10" Internet radio player Multifunctional communications devices Server for integration of third parties Audio zone player Ethernet-IR transmitter iNELS Home Control application Application for Android phones Application for Android tablets Internal antenna External antenna Thermo sensors

Open the catalog to page 12
Wired (BUS) electro-installation - 13

Wired electro-installations Smart home & building solutions

Open the catalog to page 13
Wired (BUS) electro-installation - 14

CU3-01M, CU3-02M | Central unit Technical parameters CU3-01M, CU3-02MLED Indication Green LED RUN: * Max Tightening Torque for antenna connector is 0.56 Nm.

Open the catalog to page 14
Wired (BUS) electro-installation - 15

Operating conditions Technical parameters CU3-03M LED Indication • CU3-03M is a new, enhanced version of CU3-01M and CU3-02M. • The new HW equipment allows communication with the DALI bus to connect up to 64 electronic ballasts (the internal power supply of the CU3-03M is capable of supplying connected ballasts up to a nominal value of 64 mA). • RF Communication Interface for Controlling Wireless Receivers iNELS RF Control (the current list of supported receivers is available in the iNELS Installation Guide). • The CU3-03M is equipped with three Ethernet ports, one for Ethernet (100...

Open the catalog to page 15
Wired (BUS) electro-installation - 16

CU3-01M, CU3-02M, CU3-03M Installation BUS: • Two-wired BUS with an arbitrary topology (not only to be as closed circle). • With its own modulated communications on the DC voltage supply. • One line of BUS allows you to connect up max. 32 units of iNELS3. • The current load of one line is max. 1A. When connecting units which draw greater than 1A, BPS3-01M with 3A sampling can be used. • Maximum length of the BUS is approximately 500 m (depends on the voltage drop). • Recommended cable: - iNELS BUS Cable - Twisted pair of copper wires with size of AWG20 wire (diameter of 0.812 mm,...

Open the catalog to page 16
Wired (BUS) electro-installation - 17

24 V battery battery 1 battery 2 EBM system BUS can be connected to line topology max. 8 units MI3-02M or EMDC-64M and one GSM3-01M. maximum of 32 units per line BUS; maximum 1A per line BUS Basic system connection with the central unit CU3-01M 17

Open the catalog to page 17
Wired (BUS) electro-installation - 18

PS3-100/iNELS | Power supply EAN code Indication LED switching power supply works correctly output voltage 27V is correct (Uout>24V) output voltage 12V is correct batteries are not recharged switching power supply not working correctly - UPS mode output voltage 27V is correct (UOUT>24V) output voltage 12V is correct batteries are not recharged switching power supply works correctly output voltage 27V is correct (UOUT>24V) output voltage 12V is correct batteries are recharged switching power supply not working correctly - UPS mode low output voltage 27V (21V<UOUT<24V) output voltage 12V is...

Open the catalog to page 18

All ELKO catalogs and technical brochures

  1. RFDEL-76M

    1 Pages

  2. ELKO LIGHTING

    32 Pages

  3. Smart City

    44 Pages

Archived catalogs

  1. RF-Control

    22 Pages