Catalog excerpts
• RFDEL-76M is a universal 6-channels actuator, which is used to control the brightness intensity of dimmable sources R - L - C - LED - ESL. • The maximum possible load is 150 VA for 230 V and 75 VA for 120 V for each channel. • The individual channels of the dimmer can be connected in parallel and thus increase the maximum output load at the expense of the number of outputs. • Each of the output channels is individually controllable and addressable. • By setting the min. brightness eliminates flickering of different types of light sources, setting min. brightness and type of load is done using the PROG buttons. • Electronic overcurrent, thermal and short-circuit protection, which switches off the output. • 6 galvanically isolated inputs for wired buttons, which can be used to control the outputs independently of the RF. • Communication with bidirectional RFIO2 protocol. The package includes an internal AN-I antenna, in case of placement of a sheet metal distribution element, you can use an external AN-E antenna to improve the signal. Technical parameters Supply voltage: Supply voltage frequency: Power supply indication: Supply voltage tolerance: For external inputs control buttons Output 12x MOSFET transistor R - resistive, L - inductive, C - capacitive, Load type *: Power indication ESL - economical, LED Max. output power/channel: Possible to connect outputs: max. 900 VA Maximum power when Minimum output power: Programming buttons/ Manual control Status indication channel connecting all outputs: thermal/short-term overload/longterm Output protection: Power supply overload/short circuit red LED STATUS Output indication: Control potential "L" or external voltage Wired buttons: AC 20–230 V (50–60 Hz)/DC 20–230 V up to 32-channels (with iNELS RF buttons) Communication protocol: Control voltage Function repeater: L External control buttons Other information Operating temperature: Storage temperature: -30 to +70 °C (-22 to 158 °F) IP20 under normal conditions Ingress protection: Overvoltage category: Contamination degree: Connecting conductor: Operating position: Power supply voltage *Warning: it is not allowed to simultaneously connect loads of inductive and capacitive type in the same channel. The stated outputs apply to the supply voltage AC 230 V Types of connectable loads
Open the catalog to page 1All ELKO catalogs and technical brochures
-
RFSA-66MI, RFSA-66M |
1 Pages
-
Company profile
36 Pages
-
We make World smarter
44 Pages
-
Wireless electro-installation
64 Pages
-
Highlights 2019
28 Pages
-
Wired electro-installation
60 Pages
-
Smart Home & Building Guide
36 Pages
-
ELKO LIGHTING
32 Pages
-
Product overview
52 Pages
-
Lighting control
76 Pages
-
Switches and sockets
60 Pages
-
Smart Agriculture
32 Pages
-
Wired (BUS) electro-installation
100 Pages
-
Modular electronic devices
176 Pages
-
Smart Street Lighting
24 Pages
-
Smart City
44 Pages
-
Monitoring relays
21 Pages
-
iNELS BUS general catalogue
33 Pages
-
DIM-5 | Controlled dimmer
1 Pages
-
Modular electronic devices
136 Pages
Archived catalogs
-
Product overview
36 Pages
-
RF-Control
22 Pages
-
Product Highlights
19 Pages