Catalog excerpts
MONITORING RELAYS TECHNICAL CATALOGUE
Open the catalog to page 1The company ELKO EP has been one of the leading European players in the field of residential and industrial electrical devices for more than 24 years. Since 2007, the company has been developing and producing its own system of Smart Home & Building Solutions called iNELS. EXPORT ANNUAL TURNOVER BRANCHES OVER THE WORLD EXPORTING COUNTRIES iNELS INSTALLATION At present, ELKO EP employs nearly 240 people, exports to 70 countries around the world and already has 13 foreign branches. The company is justly proud to produce it´s own components, and to have its own development and innovation of new...
Open the catalog to page 2NEW RANGE with new solution Product Lines ELKO EP RELAYS - Modular electronic devices A wide range of electronic modular devices, which bring new possibilities to home and office control, monitoring and security, as well as to industrial process control: time relays, installation contactors, staircase automatic switches, time switches clocks, dimmers, thermostats, power supplies units, control and signalling devices,GSM gates, etc. iNELS RF Control - Wireless control A unique wireless control system providing you perfect control over your home! The RF Control system enables you to control...
Open the catalog to page 3Catalogue content Product identification - explanation
Open the catalog to page 4Overview of monitoring relays Voltage monitoring relays - single-phase Under voltage monitoring relays Over voltage monitoring relays Under and over voltage monitoring relays Synchro-check monitoring relays DC Low voltage monitoring relays Voltage monitoring relays - three-phase Under voltage monitoring relays Over voltage monitoring relays Under and over voltage monitoring relays Under voltage monitoring relays Over voltage monitoring relays Under and over voltage monitoring relays Failure and phase sequence monitoring relays Failure and phase sequence monitoring relays Phase balance and...
Open the catalog to page 5VROU1-28 | Under and over voltage monitoring relays • These units monitor a single phase supply and operate relays if the phase voltage goes below or above set levels. Front panel controls allow selection of: • Under- and Over-voltage trip levels, • nominal rated voltage, • differential voltage for operating hysteresis and • time delay before a trip triggers a relay response. • LEDs indicate power on and trip status. A relay with two changeover volt-free contacts is fitted. • These instructions contain important safety information. Please read them thoroughly before commissioning, operating...
Open the catalog to page 6VRU1-18, VRO1-18 | Voltage monitoring relays • These units monitor a single phase supply and operate relays if the phase voltage goes below or above set levels. Front panel controls allow selection of: • Under (VRU1-18)- and Over- (VRO1-18) voltage trip levels, • nominal rated voltage, • differential voltage for operating hysteresis and • time delay before a trip triggers a relay response. The time delay and differential trip levels help to prevent relay chatter as the monitored voltage level varies. As the relays have changeover contacts, the relay outputs can be inverted by wiring to the...
Open the catalog to page 7VRSC1-28 | Synchro-check monitoring relays • This unit compares the voltage, frequency and phase angle of two supplies and operates a relay according to the synchronicity of the supplies. If the two supplies cease to match, the relay operates to provide a control output. The relay output can be used for alarm or control purposes. • These units monitor a voltage of 50, 75 or 150 mV, e.g. from a standard current shunt, and operates one of two relays if the voltage goes above or below set levels. Front panel controls allow selection of: • under- and over-voltage trip levels Umax, Umin •...
Open the catalog to page 8VROU3-28 | Under and over voltage monitoring relays VRU3-18, VRU3-28 | Under voltage monitoring relays • These units monitor a 3-phase 3-wire supply and operate relays if a phase-phase voltage goes below or above set levels. Front panel controls allow selection of: • Under- and Over-voltage trip levels, • nominal rated voltage, • differential voltage for operating hysteresis and • time delay before a trip triggers a relay response. • These units monitor a 3-phase 3-wire supply and operate relays if a phase-phase voltage goes below set levels. Front panel controls allow selection of: • Under...
Open the catalog to page 9VRO3-18, VRO3-28 | Over voltage monitoring relays VROU3N-28 | Under and over voltage monitoring relays 19 • These units monitor a 3-phase 3-wire supply and operate relays if a phase-phase voltage goes below set levels. Front panel controls allow selection of: • Over voltage trip levels, • nominal rated voltage, • differential voltage for operating hysteresis and • time delay before a trip triggers a relay response. • LEDs indicate power on and trip status. A relay with two changeover volt-free contacts is fitted. • These instructions contain important safety information. Please read them...
Open the catalog to page 10VRU3N-18, VRU3N-28 | Under voltage monitoring relays VRO3N-18, VRO3N-28 | Overvoltage monitoring relays 21 • These units monitor a 3-phase 4-wire supply and operate relays if a phase-neutral voltage goes below set levels. Front panel controls allow selection of: • Under voltage trip levels, • nominal rated voltage, • differential voltage for operating hysteresis and • time delay before a trip triggers a relay response. • LEDs indicate power on and trip status. A relay with two changeover volt-free contacts is fitted. • These instructions contain important safety information. Please...
Open the catalog to page 11VRSF3, VRSF3N | Failure and phase sequence monitoring relays VRSF3, VRSF3N | Failure and phase sequence monitoring relays • This unit monitors the voltage levels and phase sequence of a threephase supply and operates a relay if any phase voltage goes below a set level or if the phase sequence (L1, L2, L3) is incorrect. A front panel control allows selection of minimum voltage level. LEDs indicate power on and trip status. • Versions are available to suit 3-wire, 3ph (VRSF3) and 4-wire, 3ph+N (VRSF3N) supplies of 110V, 220V and 430V nominal. The 110V and 230V versions occupy a single module...
Open the catalog to page 12All ELKO catalogs and technical brochures
-
RFSA-66MI, RFSA-66M |
1 Pages
-
RFDEL-76M
1 Pages
-
Company profile
36 Pages
-
We make World smarter
44 Pages
-
Wireless electro-installation
64 Pages
-
Highlights 2019
28 Pages
-
Wired electro-installation
60 Pages
-
Smart Home & Building Guide
36 Pages
-
ELKO LIGHTING
32 Pages
-
Product overview
52 Pages
-
Lighting control
76 Pages
-
Switches and sockets
60 Pages
-
Smart Agriculture
32 Pages
-
Wired (BUS) electro-installation
100 Pages
-
Modular electronic devices
176 Pages
-
Smart Street Lighting
24 Pages
-
Smart City
44 Pages
-
iNELS BUS general catalogue
33 Pages
-
DIM-5 | Controlled dimmer
1 Pages
-
Modular electronic devices
136 Pages
Archived catalogs
-
Product overview
36 Pages
-
RF-Control
22 Pages
-
Product Highlights
19 Pages