Specifications:
  • Supply: AC 230V (50/60 Hz), with a power consumption of 1W (1.5 VA) and a voltage tolerance of -10% to +10%.
  • Time Circuit: Available in daily and weekly programs with a minimum switching interval of 30 minutes for daily and 3.5 hours for weekly programs. Operating accuracy is 1 second per day.
  • Output: Features 1x changeover contact (AgNi) with a rated current of 16A/AC1 and a breaking capacity of 3500 VA/AC1. The switching voltage is 250 V AC.
  • Mechanical and Electrical Life: Mechanical life is rated at 1,000,000 operations, while electrical life (AC1) is 50,000 operations.
  • Environmental Conditions: Operating temperature ranges from -10 to +50 °C (14 to 122 °F), with a storage temperature range of -10 to +50 °C. Dielectric strength is 4kV (supply-output).
  • Mounting and Protection: Designed for DIN rail EN 60715 mounting with an IP20 protection degree. Overvoltage category III and pollution degree 2.
  • Dimensions and Weight: The device measures 90 x 35 x 60 mm and weighs 117 g.
  • Standards: Complies with EN 61812-1, EN 60669-1, EN 63044-1.
Features:
  • Mechanical time switches offer a cost-effective alternative to digital switches.
  • Includes a sealable transparent front panel cover for protection.
  • Power reserve capability allows operation for up to 150 hours after a full charge.
  • Operating modes can be selected via a switch on the panel, allowing automatic switching according to the set program, permanent closure, or permanent opening.
See more

Catalog excerpts

ATS-2D, ATS-2DR, ATS-2WR | 49 AST-2D AST-2DR AST-2WR + - 1 3 2 45 C NC NO M 16 (4)A 250V 230V  50/60 Hz M ~ Analog time switches with daily/weekly progra-1

ATS-2D, ATS-2DR, ATS-2WR | Analog time switches with daily/weekly program NE Technical parameters Supply Supply terminals: Supply voltage: Power consumption (max.): Supply voltage tolerance: Supply voltage terminals (4-5) Time circuit Program: Number of switching segments: Minimum switching interval: Operating accuracy: Power reserve: Transparent opening cover weekly 3.5 hrs Direction of rotation of the programming dial Output Number of contacts: Rated current: Breaking capacity: Switching voltage: Operating mode switch Mechanical life: Time indicator Sealing spot Other information Operating temperature: Storage temperature: Dielectric strength: Operating position: Protection degree: Overvoltage category: Pollution degree: with sleeve max. 1x 4, max. 2x 1.5 (AWG 12) Dimensions: Weight: Standards: Analog time switches • The mechanical time switch is a simple and inexpensive alternative to digital time switches for controlling heating, ventilation, cooling, lighting systems or pumps depending on real time. • Daily or weekly program • Selection of operating modes using the switch on the panel: switches automatically according to the set program permanently closes permanently opens • Power reserve after power off for up to 150 hours after fully charged. • Sealable transparent front p