E-770 SERIES TEMPERATURE CONVERTERS DESCRIPTION E--770 series devices are rail-mountable industrial devices in a plastic case designed to be used as signal converters. E-770 series converters convert resistance thermometer (RTD) and thermocouple (TC) type temperature sensors, resistance and DC mV signals to standard 4 - 20 mA output signals. The input and output signals of the E-770 series devices are not galvanically isolated. E-770 series converters can be ordered as 2-wire or 4-wire types. In 2-wire types, the operating voltage and output signal are not galvanically isolated, in 4-wire types, the operating voltage and output signal are galvanically isolated. E-770 series converters can be configured with special PC software provided by Elimko. EU Directive Compliance; • Electromagnetic Compatibility Directive EN 61326-1 • Low Voltage Directive EN 61010-1 TECHNICAL SPECIFICATIONS Electrical 10 – 30 V DC (2 wire types) Operating Voltage 18 – 36 V DC (4 wire types) Voltage Drop 10 V Environmental Conditions Operating Temperature Between -10 ºC to +55 ºC Operating Humidity < 95 %Rh (non-condensing) Protection Class IP20 Calibration Temperature 25 ºC ± 3 ºC Mechanical Dimensions 90 mm x 112 mm x 6,5 mm Weight (approx.) 60 gr Connection Cables Maximum 1,5 mm2 (AWG 16) Resistance Thermometer (RTD) / Resistance Input Sensor Connection Type 3 wire Max. Wire Resistance 100 Ω Error Signaling Sensor Break Thermocouple (TC) / Millivolt Input Input Impedance > 10 MΩ Max. Wire Resistance 100 Ω Error Signaling Sensor Break Linearization Yes / No Output Output Signal 4 – 20 mA or 20 – 4 mA < ((Voperation-10) / 0,020) Ω Load Resistance ((2 wire types) Maximum 600 Ω (4 twire types) Operation Influences Ambient Temperature < ± 0,01 %/ºC CJC Error (For TC input) < ±1 ºC EMC
Open the catalog to page 1STANDARD WORKING LIMITS Inputs TC Tip B TC Tip E TC Tip J TC Tip K TC Tip L TC Tip N TC Tip R TC Tip S TC Tip T TC Tip U ORDERING GUIDE E-770 Series Signal Converters Standard Features User configurable. Input Signal Thermocouple (TC), Resistance thermometer (RTD), mV and Resistance 0 None Operating Voltage 0 2 wire 10-30 V DC 1 4 wire 18-36 V DC * E-770 series converters can be configured with special PC software to be provided by Elimko. CONNECTION DIAGRAM Connection Diagram for 2-Wire Types DC Power Supply 10 - 30 V DC Measurement / Control Device Connection Diagram for 4-Wire Types DC Power...
Open the catalog to page 27 Pages
3 Pages
4 Pages
4 Pages
5 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages