Catalog excerpts
CAVI UNIPOLARI LSZH RESISTENTI AL FUOCO A NORMA EN 50264-2-1, EN 50200 PER ROTABILI FERROVIARI LSZH FIRE RESISTANT SINGLE CORE CABLES ACCORDING TO EN 50264-2-1, EN 50200 FOR RAILWAY APPLICATION IMPIEGO: Cavi unipolari resistenti al fuoco esenti da alogeni a basso sviluppo di fumi e gas tossici e corrosivi (LSHZ) per impianti elettrici, componenti, cablaggi e sistemi ferroviari. Temperatura di esercizio: -40 +90°C STANDARD USE: Fire resistant, low smoke, low toxic and corrosive gases, halogen free (LSZH) single core cables for electric cabling and systems for railway applications Temperature range: -40 +90°C CARATTERISTICHE TECNICHE TECHNICAL FEATURES CONDUTTORI: Flessibili in rame stagnato (Cu-ETP1) sec. CEI 20-29 cl.5, EN 60228, IEC 60228 Sezioni (mm2): da 1 a 6 CONDUCTORS: Stranded tinned copper (Cu-ETP1) conductors CEI 20-29 cl.5, EN 60228, IEC 60228 ref. Cross sect. area (mm2): from 1 to 6 ISOLANTE: Nastro di vetro/mica e elastomero reticolato esente da alogeni (LSZH) ritardante la fiamma sec. CEI EN 50264-1 tipo EI101,...EI104 Codici colori: diversamente colorati INSULATION: Glass/Mica tape and LSZH special halogen free flame retardant crosslinked elastomer compound CEI EN 50264-1 class EI101,...EI104 ref. Colour code: differently coloured RAGGIO DI CURVATURA: 5 volte il diametro del cavo BENDING RADIUS: 5 times overall diameter of cable PROVA DI RESISTENZA AL FUOCO: CEI 20-36/4-0 PH 90, CEI EN 50200 PH 90 FIRE RESISTANCE TEST: CEI 20-36/4-0 PH 90, CEI EN 50200 PH 90 PROVA DI NON PROPAGAZIONE FIAMMA: CEI 20-35/1-2, EN 60332-2-1, CEI 20-22/3-4, EN 60332-3-24, IEC 60332-3-24 FLAME RETARDANT TEST: CEI 20-35/1-2, EN 60332-2-1, CEI 20-22/3-4, EN 60332-3-24, IEC 60332-3-24 1 ELETTRONICA CONDUTTORI Via Brandizzo 428/430 - 10088 VOLPIANO TO ITALY tel. +39 011 988 .47.77 - fax +39 011 988.51.23 e-mail: ec@elettronicaconduttori.
Open the catalog to page 1CAVI UNIPOLARI LSZH RESISTENTI AL FUOCO A NORMA EN 50264-2-1, EN 50200 PER ROTABILI FERROVIARI LSZH FIRE RESISTANT SINGLE CORE CABLES ACCORDING TO EN 50264-2-1, EN 50200 FOR RAIL WA Y APPLICA TION EMISSIONE Dl GAS ALOGENIDRICI: < 0,5 % (CEI 20-37/2-1, CEI EN 50267-2-1, IEC 60754-1) CORROSIVITA’ DEI GAS COMBUSTI: pH: >4,3 Conduttivita: < 10 pS/mm (CEI 20-37/2-2, CEI EN 50267-2-2, IEC 60754-2) OPACITA’ DEI FUMI: Trasmittanza: > 60% (CEI 20-37/3-1) INDICE Dl TOSSICITA’: _< 2 (CEI 20-37/7) NON-HALOGEN VERIFICA TION < 0,5 % (CEI 20-37/2-1, CEI EN 50267-2-1, IEC 60754-1) CORROSIVITY OF COMBUSTION...
Open the catalog to page 2All Elettronica Conduttori catalogs and technical brochures
-
Automation
31 Pages
-
Security
60 Pages
-
Automotive
36 Pages