video corpo

Trunking systems for air conditioning installation
14Pages

{{requestButtons}}

Catalog excerpts

Trunking systems for air conditioning installation - 1

TRUNKING SYSTEMS

Open the catalog to page 1
Trunking systems for air conditioning installation - 2

MAIN TECHNICAL FEATURES Material: technopolymer on rigid PVC base, self-extinguishing VO (UL94) and high resistant to UV rays. Standard colours: white RAL 9001. System protection degree: IP 40. Resistance to mechanical shocks IK 08 (shocks up to 5 j). Resistance to heat in continuous use: up to +70° C. Resistance to abnormal heat: up to 650° C (Glow Wire Test, Reference Standard IEC 695-2-1). Installation temperature range: minimum -5° C, maximum +60° C. Products complying with the main requirements of the regulation B.T.2006/96/CE. Products complying with the regulation RoHS 2002/95/CE....

Open the catalog to page 2
Trunking systems for air conditioning installation - 3

SPLIT System TECHNICAL SPECIFICATION Perfectly symmetric trunking base: there closing system trunking perfectly different dimensions suitable size Perforated bottom more precise cover without modern design simple click Arrangement boxes complete product trunking system is manufactured with technopolymer on rigid PVC resistant to UV rays, for a long- lasting life and a stability of the white colour RAL 9001, which can be perfectly combined with any cooling unit available on the The wide and complete range of accessories permits to make the trunking system, whether it is ceiling, perfectly...

Open the catalog to page 3
Trunking systems for air conditioning installation - 4

SPLIT System mounting examples

Open the catalog to page 4
Trunking systems for air conditioning installation - 6

SPLIT System ■COMPONENTS OF TRUNKING SYSTEMS FOR AIR CONDITIONING INSTALLATION The trunking system for air conditioning installations are composed of the trunking,the accessories for the change of direction, the joining and the derivation, that, together with the supports and the brackets, form a complete system for any installation need. The accessories for the change of direction are set directly on the trunking with a click. TRUNKING WITH WRAP-AROUND COVER MADE OF SELF-EXTINGUISHING TECHNOPOLYMER RESISTANT TO UVRAYS 90° INTERNAL ANGLE FOR CHANGE OF DIRECTION 90° EXTERNAL ANGLE FOR CHANGE...

Open the catalog to page 6
Trunking systems for air conditioning installation - 7

SPLIT System ■TRUNKING SYSTEM 60x40 SPLITsystem MAIN TECHNICAL FEATURES! ■ Made of self-extinguishing technopolymer on rigid PVC base. ■ Perforated bottom for fixing by screws or plugs. ■ Protection degree IP 40 only if installed with the proper accessories. ■ Accessories are set onto the trunking with a simple click. ■ Packed in strong cardboard boxes suitable for transport and storage. Duct for air conditioned installation Internal angle External angle Flat angle Straight joint Wall through straight joint Wall through bent joint Conduit retainer

Open the catalog to page 7
Trunking systems for air conditioning installation - 8

SPLIT System ■TRUNKING SYSTEM 70x55 SPLITsystem MAIN TECHNICAL FEATURES! ■ Made of self-extinguishing technopolymer on rigid PVC base. ■ Perforated bottom for fixing by screws or plugs. ■ Protection degree IP 40 only if installed with the proper accessories. ■ Accessories are set onto the trunking with a simple click. ■ Packed in strong cardboard boxes suitable for transport and storage. Duct for air conditioned installation Internal angle External angle Flat angle Straight joint Wall through straight joint Wall through bent joint Conduit retainer

Open the catalog to page 8
Trunking systems for air conditioning installation - 9

SPLIT System ■TRUNKING SYSTEM 80x60 SPLITsystem MAIN TECHNICAL FEATURES! ■ Made of self-extinguishing technopolymer on rigid PVC base. ■ Perforated bottom for fixing by screws or plugs. ■ Protection degree IP 40 only if installed with the proper accessories. ■ Accessories are set onto the trunking with a simple click. ■ Packed in strong cardboard boxes suitable for transport and storage. Duct for air conditioned installation Internal angle External angle Flat angle Straight joint Wall through straight joint Wall through bent joint Conduit retainer

Open the catalog to page 9
Trunking systems for air conditioning installation - 10

SPLIT System ■TRUNKING SYSTEM 90x65 SPLITsystem MAIN TECHNICAL FEATURES! ■ Made of self-extinguishing technopolymer on rigid PVC base. ■ Perforated bottom for fixing by screws or plugs. ■ Protection degree IP 40 only if installed with the proper accessories. ■ Accessories are set onto the trunking with a simple click. ■ Packed in strong cardboard boxes suitable for transport and storage. Duct for air conditioned installation Internal angle External angle Flat angle Straight joint Wall through straight joint Wall through bent joint Conduit retainer

Open the catalog to page 10
Trunking systems for air conditioning installation - 11

SPLIT System ■TRUNKING SYSTEM 100x60 SPLITsystem MAIN TECHNICAL FEATURES! ■ Made of self-extinguishing technopolymer on rigid PVC base. ■ Perforated bottom for fixing by screws or plugs. ■ Protection degree IP 40 only if installed with the proper accessories. ■ Accessories are set onto the trunking with a simple click. ■ Packed in strong cardboard boxes suitable for transport and storage. Duct for air conditioned installation Internal angle External angle Flat angle Straight joint Wall through straight joint Wall through bent joint

Open the catalog to page 11
Trunking systems for air conditioning installation - 12

SPLIT System ■ACCESSORIES FORTRUNKING SYSTEMS MAIN TECHNICAL FEATURES! ■ Made of self-extinguishing rigid technopolymer. ■ Packed in strong cardboard boxes suitable for transport and storage. I External cooling unit floor supports, with M8/10x25 fixing bolts, nuts and washers

Open the catalog to page 12
Trunking systems for air conditioning installation - 13

■ACCESSORIES FORTRUNKING SYSTEMS MAIN TECHNICAL FEATURES! ■ Made of self-extinguishing technopolymer on rigid base. • Packed in strong cardboard boxes suitable for transport and storage. ■Flexible spiral conduit for condensate draining

Open the catalog to page 13
Trunking systems for air conditioning installation - 14

SPLIT System I CHOICE TABLES FORTRUNKING SYSTEMS FOR AIR CONDITIONING INSTALLATION

Open the catalog to page 14

All Elettrocanali catalogs and technical brochures

  1. CABLE GLANDS

    10 Pages

  2. JUNCTION BOXES

    26 Pages

  3. CABLE REELS

    14 Pages