SMF3 Series
1 /1Page

SMF3 Series

SMF3 Series
1 /1Page

Catalog excerpts

SMF3 Series-1

Relay module SMF3 Series Contact data - Relay module with 3-pole relay with forcibly guided contacts according to IEC 61810-3 - Application type A - Protective separation (see insulation data) - Integration in safety applications according to IEC/EN 62061, ISO/EN 13849 possible* - Mounting on 35 mm mounting rail (IEC 60715) - Switching current max. 10 A - Switching voltage: 250 V AC/DC - Power consumption: 0,7 ... 1,15 W - Overvoltage protection in the control unit - With spring terminals (SMF219) - With screw terminals (SMF218) - Contact assembly SMF218/219: 2 NO + 1 NC Contact material AgCuNi + 0,2, ..., 0,4 μm Au Type of contact Single contact with notched crown Rated switching power 2 500 VA 250 V / 10 A / AC-1 (max.) Electr. life time (0,1 Hz, rel. duty cycle 10%) 100 000 Inrush current 30 A for 20 ms Switching voltage range 5, ..., 250 V DC / AC Switching current range* 3 mA, ..., 10 A Switching power range* 40 mW, ..., 2 500 W (VA) Contact resistance as new (max.) 100 mΩ Short circuit resistance of NO contacts** 1 000 A with pre-fuse SCPD 10 A gG / gL (fuse) Short circuit resistance of NC contacts** 1 000 A with pre-fuse SCPD 6 A gG / gL (fuse) * User is responsible for correct integration! Circuit diagram (top view) * Reference values ** Prospective short-circuit current Insulation data Electrical life (NO contacts) Rated insulation voltage (IEC 60664-1) 250 VAC Basic insulation - Air and creepage distance (min.) 2,5 mm - Test voltage 2 500 Vrms / 1 min Double or reinforced insulation - Air and creepage distance (min.) 5,5 mm - Test voltage 4 000 Vrms / 1 min Open contact: Test voltage* 1 500 Vrms / 1 min Pollution degree 2 Overvoltage category III * Initial value Mechanical data Switching capacity (IEC 61810-1) AC-1: 240 V / 10 A MAX AC-15: 240 V / 5 A MAX DC-1: 24 V / 10 A MAX DC-13: 24 V / 5 A / 0,1 Hz MAX Switching capacity (UL 508) Continuous current per contact at load of: 1 contact 2 contacts Contact load limit curve (DC) Module data excitation side at 20 °C Mechanical lifetime (min.) 10 x 106 operations Switching frequency (max.) 15 Hz Response time (NO closed) (typ.) 12 ms Drop-out time (NC closed) (typ.)* 5 ms Bounce time (typ.) NO: 1,5 ms / NC: 15 ms Shock resistance (16 ms) (min.) NO: 14g / NC: 4g Vibration resistance (10-200 Hz) (min.) NO: 6g / NC: 4g Weight approx. 110 g Mounting position any * without coil wiring Technical data Connection data Screw terminal: - Cross sections for wire: 0,2 - 2,5 mm2 / AWG 24 - 14 - Cross sections for braid: 0,2 - 2,5 mm2 / AWG 24 - 12 - Tightening torque: 0,6 Nm Connection data spring terminal: - Cross sections for wire: 0,2 - 2,0 mm2 / AWG 24 - 14 - Cross sections for braid: 0,2 - 2,5 mm2 / AWG 24 - 12 Other data Ambient temperature Thermal resistance Protection class Approvals UL File Mounting instructions Mounting Options, Accessories Other coil designs Test conditions: - Graph 1: Contact current 6 A MAX - Graph 2: without previous operation - Duty cycle 100% ELESTA GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Type designation Number of contacts NO Number of contacts NC Connection technology Nominal coil voltage Options

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.