Features:
- The SIS6 sensitive series relay features forcibly guided contacts compliant with IEC 61810-3, suitable for application type A, and offers protective separation. It is designed for print mounting, has a compact design, and operates with low nominal and holding power. The contact assembly is SIS422 SEN: 4 NO + 2 NC.
Dimensions:
- Pin dimensions are 1.0 x 0.3 mm and 1.0 x 0.4 mm, with a recommended PCB drilling diameter of 1.3 mm.
Coil Data at 20°C:
- Nominal power is 0.44 W, holding power is 0.10 W, and the coil limit temperature is 120°C. Nominal voltage ranges from 3.0 VDC to 60.0 VDC with corresponding minimum pick-up and drop-out voltages, nominal current, and resistance values provided.
Insulation Data:
- Rated insulation voltage is 250 VAC with basic and double/reinforced insulation specifications, including air and creepage distances and test voltages. Insulation resistance is a minimum of 100 MΩ.
Mechanical Data:
- The relay has a mechanical lifetime of at least 10 million operations, a maximum switching frequency of 15 Hz, and specific response and drop-out times. It is resistant to shock and vibration, weighs approximately 35 g, and can be mounted in any position.
Other Data:
- The relay operates within an ambient temperature range of -40°C to +85°C, has a thermal resistance of 45 K/W, and is classified under protection class RT III. It is approved by cULus and TÜV, with a flammability class of UL 94 V-0.
Options and Accessories:
- Variations in pin lengths and coil designs are possible, including coils for railway applications according to EN 50155.
Contact Data:
- Contacts are made of AgCuNi with a gold layer, rated for a switching power of 1,500 VA and a maximum of 250 V / 6 A / AC-1. The electrical lifetime is 90,000 operations at 0.1 Hz. The relay can handle inrush currents up to 30 A for 20 ms and has a contact resistance of 100 mΩ when new.
Electrical Life (NO Contacts):
- The relay's switching capacity is specified for various conditions, including AC-1, AC-15, DC-1, and DC-13, with maximum continuous current per contact detailed.
See more

Catalog excerpts

SIS6 sensitive Series-1

Relays SIS6 sensitive Series Contact data - Relay with forcibly guided contacts according to IEC 61810-3 - Application type A - Protective separation (see insulation data) - Suitable for print mounting - Compact design - Low nominal and holding power - Contact assembly SIS422 SEN: 4 NO + 2 NC Contact material AgCuNi + 0,2, ..., 0,4 μm Au Type of contact Single contact with notched crown Rated switching power 1 500 VA 250 V / 6 A / AC-1 (max.) Electr. life time (0,1 Hz, rel. duty cycle 10%) 90 000 Inrush current 30 A for 20 ms Switching voltage range 5, ..., 250 V DC / AC Switching current range* 3 mA, ..., 6 A Switching power range* 40 mW, ..., 1 500 W (VA) Contact resistance as new (max.) 100 mΩ Short circuit resistance of contacts** 1 000 A with pre-fuse SCPD 6 A gG / gL (fuse) Circuit diagram (top view) * Reference values ** Prospective short-circuit current Insulation data Electrical life (NO contacts) Pin dimension b Pin dimension c Recommended drilling on PCB Rated insulation voltage (IEC 60664-1) Basic insulation - Air and creepage distance (min.) - Test voltage Double or reinforced insulation - Air and creepage distance (min.) - Test voltage Double or reinforced insulation - Air and creepage distance (min.) - Test voltage Open contact: Test voltage* Creepage resistance Pollution degree Overvoltage category Insulation resistance (min.) - Test voltage 250 VAC 4 mm 2 500 Vrms / 1 min 5,5 mm 4 000 Vrms / 1 min 8 mm 4 000 Vrms / 1 min 1 500 Vrms / 1 min CTI 175 2 III 100 MΩ 500 VDC * Initial value Nominal power (typ.) Holding power (typ.) Coil limit temperature Switching capacity (IEC 61810-1) AC-1: 240 V / 6 A MAX AC-15: 240 V / 3 A MAX DC-1: 24 V / 6 A MAX DC-13: 24 V / 5 A / 0,1 Hz MAX Switching capacity (UL 508) Continuous current per contact at load of: 1 or 2 contacts 3 contacts 4 contacts Contact load limit curve (DC) Mechanical data Mechanical lifetime (min.) 10 x 106 operations Switching frequency (max.) 15 Hz Response time (NO closed) (typ.) 20 ms Drop-out time (NC closed) (typ.)* 4 ms Bounce time (typ.) NO: 2 ms / NC: 15 ms Shock resistance (16 ms) (min.) NO: 10g / NC: 9g Vibration resistance (10-200 Hz) (min.) NO: 10g / NC: 3g Weight approx. 35 g Mounting position any Mounting distance (min.) 1 mm * without coil wiring  Excitation voltage range Other data Ambient temperature Thermal resistance Protection class Solder bath temperature Test method (heating) Approvals Flammability class UL File -40 °C, ..., +85 °C 45 K / W RT III 270 °C / 5 s A (group assembly) cULus, TÜV UL 94 V-0 E188 953 Sec. 5 Options, Accessories Other pin lengths possible Other coil designs possible Coils accord. to EN 50155 (railway applications) possible Test conditions: - Graph 1: Contact current 4 A MAX - Graph 2: without previous operation - Free-standing relay on PCB - Duty cycle 100% ELESTA GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Type designation Number of contacts NO Number of contacts NC Connection technology Nominal coil voltage