SIS4 Series

SIS4 Series

Product catalog summary
Features
The SIS4 Series relays feature forcibly guided contacts compliant with IEC 61810-3, suitable for print mounting, and offer protective separation. The contact assembly options include SIS222 with 2 NO + 2 NC, and SIS312 with 3 NO + 1 NC configurations.
Dimensions and Mounting
Pin dimensions are specified as 1.0 x 0.3 mm and 1.0 x 0.4 mm, with a recommended PCB drilling diameter of 1.3 mm. The relays can be mounted in any position with a minimum mounting distance of 1 mm.
Coil Data
At 20°C, the nominal power is 0.5 W, and the holding power is 0.15 W. The coil limit temperature is 120°C. Nominal voltages range from 5 VDC to 110 VDC, with corresponding minimum pick-up and drop-out voltages provided.
Insulation Data
The rated insulation voltage is 250 VAC, with basic and reinforced insulation specifications including air and creepage distances and test voltages. The insulation resistance is a minimum of 100 MΩ.
Mechanical Data
The mechanical lifetime is at least 10 million operations, with a maximum switching frequency of 15 Hz. Response and drop-out times are 15 ms and 5 ms, respectively. The relay weighs approximately 30 g.
Environmental and Approval Data
The operating temperature range is -40°C to +85°C, with a thermal resistance of 45 K/W. The protection class is RT III, and the relays are approved by cULus and TÜV, with a flammability class of UL 94 V-0.
Contact Data
Contacts are made of AgCuNi with a gold layer, supporting a rated switching power of 1500 VA. The electrical lifetime is 90,000 operations at 0.1 Hz. The switching voltage range is 5 to 250 V DC/AC, and the switching current range is 3 mA to 6 A.
Switching Capacity
According to IEC 61810-1, the maximum switching capacities are 240 V/6 A for AC-1, 240 V/3 A for AC-15, 24 V/6 A for DC-1, and 24 V/5 A for DC-13. Under UL 508, the capacities are B300 and R300.
See more

Catalog excerpts

SIS4 Series-1

Contact data - Relay with forcibly guided contacts according to IEC 61810-3 - Application type A - Protective separation (see insulation data) - Suitable for print mounting - Contact assembly SIS222: 2 NO + 2 NC, SIS312: 3 NO + 1 NC, SIS312 KV2: 3 NO + 1 NC Contact material AgCuNi + 0,2, ..., 0,4 μm Au Type of contact Single contact with notched crown Rated switching power 1 500 VA 250 V / 6 A / AC-1 (max.) Electr. life time (0,1 Hz, rel. duty cycle 10%) 90 000 Inrush current 30 A for 20 ms Switching voltage range 5, ..., 250 V DC / AC Switching current range* 3 mA, ..., 6 A Switching power range* 40 mW, ..., 1 500 W (VA) Contact resistance as new (max.) 100 mΩ Short circuit resistance of contacts** 1 000 A with pre-fuse SCPD 6 A gG / gL (fuse) Circuit diagram (top view) * Reference values ** Prospective short-circuit current Insulation data Electrical life (NO contacts) 10000 5000 1000 Pin dimension b Pin dimension c Recommended drilling on PCB Nominal power Holding power Coil limit temperature Switching capacity (IEC 61810-1) AC-1: 240 V / 6 A MAX AC-15: 240 V / 3 A MAX DC-1: 24 V / 6 A MAX DC-13: 24 V / 5 A / 0,1 Hz MAX Switching capacity (UL 508) Continuous current per contact at load of: 1 or 2 contacts 3 contacts Contact load limit curve (DC) * Initial value Mechanical data Mechanical lifetime (min.) 10 x 106 operations Switching frequency (max.) 15 Hz Response time (NO closed) (typ.) 15 ms Drop-out time (NC closed) (typ.)* 5 ms Bounce time (typ.) NO: 2 ms / NC: 15 ms Shock resistance (16 ms) (min.) NO: 10g / NC: 10g Vibration resistance (10-200 Hz) (min.) NO: 10g / NC: 4g Weight approx. 30 g Mounting position any Mounting distance (min.) 1 mm Ambient temperature Thermal resistance Protection class Solder bath temperature Test method (heating) Approvals Flammability class UL File -40 °C, ..., +85 °C 45 K / W RT III 270 °C / 5 s A (group assembly) cULus, TÜV UL 94 V-0 E188 953 Sec. 5 Other pin lengths possible Other coil designs possible Coils accord. to EN 50155 (railway applications) possible Options, Accessories Other Data * without coil wiring  Excitation voltage range Rated insulation voltage (IEC 60664-1) Basic insulation - Air and creepage distance (min.) - Test voltage Double or reinforced insulation - Air and creepage distance (min.) - Test voltage Double or reinforced insulation - Air and creepage distance (min.) - Test voltage Open contact: Test voltage* Creepage resistance Pollution degree Overvoltage category Insulation resistance (min.) - Test voltage Test conditions: - Graph 1: Contact current 4 A MAX - Graph 2: without previous operation - Free-standing relay on PCB - Duty cycle 100% ELESTA GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Type designation Number of contacts NO Number of contacts NC Connection technolog

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.