SIS2 Series
1Pages

{{requestButtons}}

Catalog excerpts

SIS2 Series - 1

Contact data - Relay with forcibly guided contacts according to IEC 61810-3 - Application type A - Protective separation (see insulation data) - Suitable for print mounting - Small design - Contact assembly SIS112: 1 NO + 1 NC Contact material AgCuNi + 0,2, ..., 0,4 μm Au Type of contact Single contact with notched crown Rated switching power 1 500 VA 250 V / 6 A / AC-1 (max.) Electr. life time (0,1 Hz, rel. duty cycle 10%) 90 000 Inrush current 30 A for 20 ms Switching voltage range 5, ..., 250 V DC / AC Switching current range* 3 mA, ..., 6 A Switching power range* 40 mW, ..., 1 500 W (VA) Contact resistance as new (max.) 100 mΩ Short circuit resistance of contacts** 1 000 A with pre-fuse SCPD 6 A gG / gL (fuse) Circuit diagram (top view) * Reference values ** Prospective short-circuit current Electrical life (NO contacts) Insulation data Rated insulation voltage (IEC 60664-1) 250 VAC Basic insulation - Air and creepage distance (min.) 4 mm - Test voltage 2 500 Vrms / 1 min Double or reinforced insulation - Air and creepage distance (min.) 10 mm - Test voltage 5 000 Vrms / 1 min Open contact: Test voltage* 1 500 Vrms / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance (min.) 100 MΩ - Test voltage 500 VDC * Initial value Mechanical data Pin dimension b Pin dimension c Recommended drilling on PCB Nominal power (typ.) Holding power (typ.) Coil limit temperature Switching capacity (IEC 61810-1) AC-1: 240 V / 6 A MAX AC-15: 240 V / 3 A MAX DC-1: 24 V / 6 A MAX DC-13: 24 V / 5 A / 0,1 Hz MAX Switching capacity (UL 508) Continuous current per contact at load of: 1 contact 4,0 Excitation voltage range * without coil wiring  Other data Ambient temperature Thermal resistance Protection class Solder bath temperature Test method (heating) Approvals Flammability class UL File Mounting rail socket SRD SIS3 Pin lengths for mounting rail socket 3,8 mm Other pin lengths possible Other coil designs possible Coils accord. to EN 50155 (railway applications) possible -40 °C, ..., +85 °C 55 K / W RT III 270 °C / 5 s A (group assembly) cULus, TÜV UL 94 V-0 E188 953 Sec. 5 Contact load limit curve (DC) Mechanical lifetime (min.) 10 x 106 operations Switching frequency (max.) 15 Hz Response time (NO closed) (typ.) 10 ms Drop-out time (NC closed) (typ.)* 3 ms Bounce time (typ.) NO: 2 ms / NC: 15 ms Shock resistance (16 ms) (min.) NO: 17g / NC: 7g Vibration resistance (10-200 Hz) (min.) NO: 7g / NC: 2g Weight approx. 18 g Mounting position any Mounting distance (min.) 1 mm Test conditions: - Graph 1: Contact current 4 A MAX - Graph 2: without previous operation - Free-standing relay on PCB - Duty cycle 100% ELESTA GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Type designation Number of contacts NO Number of contacts NC Connection technology Nominal coil

Open the catalog to page 1

All ELESTA GmbH catalogs and technical brochures

  1. SMD4 Series

    1 Pages

  2. SMF5 Series

    1 Pages

  3. SMF3 Series

    1 Pages

  4. SMD4 Series

    1 Pages

  5. SRD SIS3

    1 Pages

  6. SRD SIM4

    1 Pages

  7. SRD SGR2

    1 Pages

  8. SIP6 Series

    1 Pages

  9. SIM4 Series

    1 Pages

  10. SIM3 Series

    1 Pages

  11. SIM2 Series

    1 Pages

  12. SIF4 Series

    1 Pages

  13. SIF6 Series

    1 Pages

  14. SIF4 Series

    1 Pages

  15. SIF3 Series

    1 Pages

  16. SIS4 Series

    1 Pages

  17. SIS3 Series

    1 Pages

  18. SISF2 Series

    1 Pages

  19. SIR10 Series

    1 Pages

  20. SIR8 Series

    1 Pages

  21. SID4 Series

    1 Pages

  22. SIR 8 Series

    1 Pages

  23. SIR 6 Series

    1 Pages

  24. SIR 4 Series

    1 Pages

  25. SLR 4 Series

    1 Pages

  26. SIM 2 Series

    1 Pages

  27. SIF 6 Series

    1 Pages

  28. SIF 4 Series

    1 Pages

  29. SIF 3 Series

    1 Pages

  30. SIS 6 Series

    1 Pages

  31. SIS 4 Series

    1 Pages

  32. SIS 3 Series

    1 Pages

  33. SIS 2 Series

    1 Pages

Archived catalogs