SIS 4 Series

SIS 4 Series

Product catalog summary
Specifications:
- Basic insulation at 250 VAC with air and creepage distance >4 mm, test voltage 2500 V / 50 Hz / 1 min.
- Double or reinforced insulation at 250 VAC with air and creepage distance >5.5 mm, test voltage 4000 V / 50 Hz / 1 min.
- Test voltage contact open 1500 V / 50 Hz / 1 min.
- Creepage resistance CTI 175, Pollution degree 2, Overvoltage category III.
- Insulation resistance at Up 500 VDC >100 MΩ.
Additional Data:
- Mechanical endurance >10 x 106 operations, Switching frequency 15 Hz.
- Response time typically 15 ms, Drop-out time typically 5 ms.
- Shock resistance 16 ms NO > 10g, NC > 10g.
- Vibration resistance NO > 10g, NC > 4g.
- Ambient temperature -40°C to +85°C, Thermal Resistance 45 K / W.
- Weight approx. 30 g, Mounting position any, Mounting distance recommended >1 mm.
- Solder bath temperature 270°C / 5 s.
Tests, Regulations, Standards:
- Approvals: UL File E188953 Sec. 5.
- Insulation class IEC 60664-1 250 VAC.
- Fire protection requirements UL 94 / V0.
- Standards: IEC 61810-1, IEC 61810-3.
Contact Data:
- Contact material AgCuNi +0.2-0.4 µm Au.
- Rated switching capacity 250 VAC 6 A AC1 1500 VA.
- Inrush current max. 30 A for 20 ms.
- Switching voltage range 5 to 250 VDC / VAC.
- Switching current range 3 mA to 6 A.
- Contact resistance ≤100 mΩ / 6 V / 100 mA.
Standard Coils for Direct Current:
- Nominal voltages range from 5 VDC to 110 VDC with varying pick-up and drop-out voltages, currents, and resistances.
Relay Key Data:
- PCB relay with forcibly guided contacts.
- Protective separation between control and load circuit with leakage and creepage distances > 8 mm.
- Contact mounting: SIS312 3 NO / 1 NC, SIS222 2 NO / 2 NC.
- Nominal coil power 0.5 W, Holding coil power 0.15 W.
See more

Catalog excerpts

SIS 4 Series-1

SIS 4 Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contacts - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distances > 8 mm) - IEC 61810-3 Type A - Double and reinforced insulation between the contacts - Contact mounting: SIS312 3 NO / 1 NC SIS222 2 NO / 2 NC - Small external dimensions - Nominal coil power 0,5 W - Holding coil power 0,15 W - Coil for railway application according EN 50155 on request Insulation Data - Test voltage2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - ■ — ■ - - Air and creepage distance >5,5 mm - Test voltage4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC ^■ - Air and creepage distance >8 mm - Test voltage4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistanceCTI 175 Pollution degree2_ Overvoltage categoryIII Insulation resistance at Up 500 VDC>100 MQ Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 6 A Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each Additional Data Mechanical endurance_ Switching frequency, mechanical Response time (all NO closed) Drop-out time** (NC closed) Bounce time of NO contact_ Bounce time of NC contact_ Contact Data Contact materialAgCuNi +0,2-0,4 pm Au Type of contact Single contact with notched crown Rated switching capacity250 VAC 6 A AC1 1500 VA Electr. Life AC1(360 S / h) >90000 Inrush current max.30 A for 20 ms Switching voltage range5 to 250 VDC / VAC Switching current range*3 mA to 6 A Switching capacity range*40 mW to 1500 W(VA) Contact resistance (as delivered) <100 mQ / 6 V / 100 mA *Guided values >10 x 106 operations 15 Hz typically 15 ms typically 5 ms typically 2 ms typically 15 ms NO > 10g NC > 10g NO > 10g NC > 4g Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Standard Coils for Direct Current Ambient temperature Thermal Resistance Temperature limit for coil Weight Mounting position Mounting distance Test method Type of protection Solder bath temperature -40°C to +85°C _45 K / W 120°C approx. 30 g any _rec. >1 mm A / group assembly RT III 270°C / 5 s Excitation Voltage Range (other voltages on request) **without spark suppression Tests, Regulations, Standards Insulation class IEC 60664-1 Fire protection requirements_ Options, Accessories none available 1) Max. excitation voltage with contact load: <4 A 2) Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. _Contact variant _Nominal voltage _Solder terminals Number of NC contacts Number of NO contacts _Type designation

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.