1. Catalogs
  2. ELESTA GmbH
  3. SIS 4 sensitive Series

SIS 4 sensitive Series

SIS 4 sensitive Series

Product catalog summary
Specifications:
The document provides detailed specifications for a relay, including insulation data, mechanical endurance, and switching characteristics. The relay offers basic insulation at 250 VAC with air and creepage distances greater than 4 mm, and double or reinforced insulation with distances greater than 5.5 mm and 8 mm, tested at 4000 V / 50 Hz for 1 minute. It has a creepage resistance of CTI 175, pollution degree 2, and overvoltage category III. The insulation resistance at Up 500 VDC is greater than 100 MΩ.
Mechanical and Electrical Data:
The relay has a mechanical endurance of over 10 million operations and a switching frequency of 15 Hz. The response time for all normally open (NO) contacts closed is typically 20 ms, with a drop-out time of 4 ms for normally closed (NC) contacts. The shock resistance is greater than 10g for both NO and NC contacts, and vibration resistance is greater than 10g for NO and 4g for NC contacts. The ambient temperature range is -40°C to +85°C, with a thermal resistance of 45 K/W and a coil temperature limit of 120°C.
Standards and Approvals:
The relay complies with UL File E188953 Sec. 5, insulation class IEC 60664-1 250 VAC, and fire protection requirements UL 94 / V0. It adheres to standards IEC 61810-1 and IEC 61810-3.
Contact Data:
The contact material is AgCuNi with a gold layer of 0.2-0.4 µm. The rated switching capacity is 250 VAC 6 A AC1 1500 VA, with an electrical life of over 90,000 operations at AC1. The inrush current is a maximum of 30 A for 20 ms, with a switching voltage range of 5 to 250 VDC/VAC and a switching current range of 3 mA to 6 A.
Coil Data:
Standard coils for direct current are available with nominal voltages ranging from 3.0 VDC to 60.0 VDC, with corresponding pick-up and drop-out voltages, nominal current, and resistance values provided.
Additional Features:
The relay is a PCB relay with forcibly guided contacts, offering protective separation between control and load circuits with leakage and creepage distances greater than 8 mm. It is suitable for railway applications according to EN 50155 upon request.
See more

Catalog excerpts

SIS 4 sensitive Series-1

SIS 4 sensitive Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contacts - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distances > 8 mm) - IEC 61810-3 Type A - Double and reinforced insulation between the contacts - Contact mounting: SIS312 3 NO / 1 NC SIS222 2 NO / 2 NC - Small external dimensions - Nominal coil power 0,33 W - Holding coil power 0,08 W - Coil for railway application according EN 50155 on request Insulation Data - Test voltage2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - ■ — ■ - - Air and creepage distance >5,5 mm - Test voltage4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC ^■ - Air and creepage distance >8 mm - Test voltage4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistanceCTI 175 Pollution degree 2 Overvoltage categoryIII_ Insulation resistance at Up 500 VDC >100 MQ Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 6 A Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each Additional Data Contact Data Mechanical endurance_ Switching frequency, mechanical Response time (all NO closed) Drop-out time** (NC closed) Bounce time of NO contact_ Bounce time of NC contact Shock resistance 16 ms Contact materialAgCuNi +0,2-0,4 pm Au Type of contact Single contact with notched crown Rated switching capacity250 VAC 6 A AC1 1500 VA Electr. Life AC1 (360 S / h) >90000 Inrush current max.30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range*3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) <100 mQ / 6 V / 100 mA *Guided values >10 x 106 operations 15 Hz typically 20 ms typically 4 ms typically 2 ms typically 15 ms NO > 10g NC > 10g NO > 10g NC > 4g Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Standard Coils for Direct Current Ambient temperature Thermal Resistance Temperature limit for coil Weight Mounting position Mounting distance Test method Type of protection Solder bath temperature -40°C to +85°C _45 K / W _120°C approx. 30 g any rec. >1 mm A / group assembly RT III 270°C / 5 s Excitation Voltage Range (other voltages on request) **without spark suppression Tests, Regulations, Standards Insulation class IEC 60664-1 Fire protection requirements_ Options, Accessories none available _Contact variant _Sensitive coil _Nominal voltage _Solder terminals Number of NC contacts Number of NO contacts _Type designation 1) Max. excitation voltage with contact load: <4 A 2) Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%.