Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances > 8 mm) -- IEC 61 810-3 Type A -- Double and reinforced insulation between the contacts -- Contact mounting: SIS212 2 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,6 W -- Holding coil power 0,18 W -- Coil for railway application according EN 50 155 on request Contact material AgCuNi +0,2-0,4 µm Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) ≤100 mΩ / 6 V / 100 mA *Guided values Standard Coils for Direct Current (other voltages on request) -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 MΩ Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 10 ms Drop-out time (NC closed) typically 3 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 17g NC > 10g Vibration resistance NO > 7g (10-200 Hz) NC > 3g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40°C to +85°C Thermal Resistance 55 K / W Temperature limit for coil 120°C Weight approx. 20 g Mounting position any Mounting distance rec. >1 mm Test method A / group assembly Type of protection RT III Solder bath temperature 270°C / 5 s **without spark suppression Approvals UL File E188 953 Insulation class IEC 60 664-1 Fire protection requirements Standards IEC 61 810-1, IEC 61810-3 none available Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each Load Limit Curve with Direct Current 6 4 3 2 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 2,5 2,0 Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 1) Max. excitation voltage with contact load: ≤4 A 2) Min. excitation voltage (guaranteed values) without previous operation Options, Accessories Tests, Regulations, Standards Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Additional Data Contact Data Insulation Data Contact Lifetime for NO Contacts Nominal voltage Solder terminals Number of NC
Open the catalog to page 11 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
36 Pages
36 Pages