SIS 3 Series
1 /1Page

SIS 3 Series

SIS 3 Series
1 /1Page

Catalog excerpts

SIS 3 Series-1

Circuit Diagram (relay top view) -- PCB relay with forcibly guided contacts -- Protective separation between control and load circuit (leakage and creepage distances > 8 mm) -- IEC 61 810-3 Type A -- Double and reinforced insulation between the contacts -- Contact mounting: SIS212 2 NO / 1 NC -- Small external dimensions -- Nominal coil power 0,6 W -- Holding coil power 0,18 W -- Coil for railway application according EN 50 155 on request Contact material AgCuNi +0,2-0,4 µm Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1 500 VA Electr. Life AC1 (360 S / h) >90 000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) ≤100 mΩ / 6 V / 100 mA *Guided values Standard Coils for Direct Current (other voltages on request) -- Basic insulation at 250 VAC -- Air and creepage distance >4 mm -- Test voltage 2500 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >5,5 mm -- Test voltage 4000 V / 50 Hz / 1 min -- Double or reinforced insulation at 250 VAC -- Air and creepage distance >8 mm -- Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 MΩ Mechanical endurance >10 x 106 operations Switching frequency, mechanical 15 Hz Response time (all NO closed) typically 10 ms Drop-out time (NC closed) typically 3 ms Bounce time of NO contact typically 2 ms Bounce time of NC contact typically 15 ms Shock resistance 16 ms NO > 17g NC > 10g Vibration resistance NO > 7g (10-200 Hz) NC > 3g Resistance to short circuiting contacts 1 000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40°C to +85°C Thermal Resistance 55 K / W Temperature limit for coil 120°C Weight approx. 20 g Mounting position any Mounting distance rec. >1 mm Test method A / group assembly Type of protection RT III Solder bath temperature 270°C / 5 s **without spark suppression Approvals UL File E188 953 Insulation class IEC 60 664-1 Fire protection requirements Standards IEC 61 810-1, IEC 61810-3 none available Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each Load Limit Curve with Direct Current 6 4 3 2 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 2,5 2,0 Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. ELESTA GmbH, Heuteilstrasse 18, Phone: CH - 7310 Bad Ragaz, Switzerland 1) Max. excitation voltage with contact load: ≤4 A 2) Min. excitation voltage (guaranteed values) without previous operation Options, Accessories Tests, Regulations, Standards Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Additional Data Contact Data Insulation Data Contact Lifetime for NO Contacts Nominal voltage Solder terminals Number of NC

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.