1. Catalogs
  2. ELESTA GmbH
  3. SIS 2 sensitive Series

SIS 2 sensitive Series

SIS 2 sensitive Series

Product catalog summary
Insulation Data:
  • Basic insulation at 250 VAC with air and creepage distance >4 mm, test voltage 2500 V / 50 Hz / 1 min.
  • Double or reinforced insulation at 250 VAC with air and creepage distance >10 mm, test voltage 5000 V / 50 Hz / 1 min.
  • Test voltage contact open: 1500 V / 50 Hz / 1 min.
  • Creepage resistance: CTI 175, Pollution degree: 2, Overvoltage category: III.
  • Insulation resistance at Up 500 VDC >100 MΩ.
Additional Data:
  • Mechanical endurance >10x106 operations, switching frequency: 12 Hz.
  • Response time (NO closed): 15 ms, Drop-out time (NC closed): 5 ms.
  • Bounce time: NO contact 2 ms, NC contact 15 ms.
  • Shock resistance: NO > 17g, NC > 7g; Vibration resistance: NO > 7g, NC > 2g.
  • Resistance to short circuiting contacts: 1000 A SCPD 6 A gG / gL (pre-fuse).
  • Ambient temperature: -40°C to +85°C, Thermal Resistance: 55 K / W, Temperature limit for coil: 120°C.
  • Weight: approx. 18 g, Mounting position: any, Mounting distance recommended >1 mm.
  • Test method: A / group assembly, Type of protection: RT III, Solder bath temperature: 270°C / 5 s.
Tests, Regulations, Standards:
  • Approvals: UL File E188953 Sec. 5.
  • Insulation class: IEC 60664-1 250 VAC.
  • Fire protection requirements: UL 94 / V0.
  • Standards: IEC 61810-1, IEC 61810-3.
Product Key:
  • SIS 1 1 2 24VDC SEN - Sensitive coil, Nominal voltage, Solder terminals, Number of NC contacts, Number of NO contacts, Type designation.
Contact Data:
  • Contact material: AgCuNi +0.2-0.4 µm Au, Type of contact: Single contact with notched crown.
  • Rated switching capacity: 250 VAC 6 A AC1 1500 VA, Electr. Life AC1 (360 S / h) >90000.
  • Inrush current max.: 30 A for 20 ms, Switching voltage range: 5 to 250 VDC / VAC.
  • Switching current range: 3 mA to 6 A, Switching capacity range: 40 mW to 1500 W(VA).
  • Contact resistance (as delivered): ≤100 mΩ / 6 V / 100 mA.
Standard Coils for Direct Current:
  • Nominal voltage range from 3.0 VDC to 60.0 VDC with corresponding pick-up and drop-out voltages, nominal current, and resistance values.
Relay Key Data:
  • PCB relay with forcibly guided contacts, protective separation between control and load circuit (leakage and creepage distances > 10 mm).
  • IEC 61810-3 Type A, Double and reinforced insulation between the contacts.
  • Contact mounting: SIS112 1 NO / 1 NC, Small external dimensions.
  • Nominal coil power: 0.2 W, Holding coil power: 0.04 W.
See more

Catalog excerpts

SIS 2 sensitive Series-1

SIS 2 sensitive Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contact - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distances > 10 mm) - IEC 61810-3 Type A - Double and reinforced insulation between the contacts - Contact mounting: SIS112 1 NO / 1 NC - Small external dimensions - Nominal coil power 0,2 W - Holding coil power 0,04 W - Test voltage2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC ^■ - Air and creepage distance >10 mm - Test voltage5000 V / 50 Hz / 1 min Test voltage contact open1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree2_ Overvoltage category III Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 6 A Load Limit Curve with Direct Current Additional Data Contact Data Contact materialAgCuNi +0,2-0,4 pm Au Type of contactSingle contact with notched crown Rated switching capacity250 VAC 6 A AC1 1500 VA Electr. Life AC1 (360 S / h) >90000 Inrush current max.30 A for 20 ms Switching voltage range5 to 250 VDC / VAC Switching current range*3 mA to 6 A Switching capacity range*40 mW to 1500 W(VA) Contact resistance (as delivered) <100 mQ / 6 V / 100 mA *Guided values Mechanical endurance Switching frequency, mechanical Response time (NO closed) Drop-out time (NC closed)_ Bounce time of NO contact Bounce time of NC contact_ >10x106 operations 12 Hz typically 15 ms typically 5 ms typically 2 ms typically 15 ms NO > 17g NC > 7g NO > 7g NC > 2g Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Thermal Resistance55 K / W Temperature limit for coil 120 °C Voltage (VDC) ^ 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range Standard Coils for Direct Current (other voltages on request) Weight Mounting position Mounting distance Test method Type of protection Solder bath temperature **without spark suppression approx. 18 g any rec. >1 mm A / group assembly RT III 270 °C / 5 s Tests, Regulations, Standards Fire protection requirements_ Options, Accessories none available 1) Max. excitation voltage with contact load: <4 A 2) Min. excitation voltage (guaranteed values) without previous operation _Sensitive coil _Nominal voltage _Solder terminals Number of NC contacts Number of NO contacts _Type designation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%.