1. Catalogs
  2. ELESTA GmbH
  3. SIS 2 sensitive Series

SIS 2 sensitive Series
1 /1Page

SIS 2 sensitive Series

SIS 2 sensitive Series
1 /1Page

Catalog excerpts

SIS 2 sensitive Series-1

SIS 2 sensitive Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contact - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distances > 10 mm) - IEC 61810-3 Type A - Double and reinforced insulation between the contacts - Contact mounting: SIS112 1 NO / 1 NC - Small external dimensions - Nominal coil power 0,2 W - Holding coil power 0,04 W - Test voltage2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC ^■ - Air and creepage distance >10 mm - Test voltage5000 V / 50 Hz / 1 min Test voltage contact open1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree2_ Overvoltage category III Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 6 A Load Limit Curve with Direct Current Additional Data Contact Data Contact materialAgCuNi +0,2-0,4 pm Au Type of contactSingle contact with notched crown Rated switching capacity250 VAC 6 A AC1 1500 VA Electr. Life AC1 (360 S / h) >90000 Inrush current max.30 A for 20 ms Switching voltage range5 to 250 VDC / VAC Switching current range*3 mA to 6 A Switching capacity range*40 mW to 1500 W(VA) Contact resistance (as delivered) <100 mQ / 6 V / 100 mA *Guided values Mechanical endurance Switching frequency, mechanical Response time (NO closed) Drop-out time (NC closed)_ Bounce time of NO contact Bounce time of NC contact_ >10x106 operations 12 Hz typically 15 ms typically 5 ms typically 2 ms typically 15 ms NO > 17g NC > 7g NO > 7g NC > 2g Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Thermal Resistance55 K / W Temperature limit for coil 120 °C Voltage (VDC) ^ 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range Standard Coils for Direct Current (other voltages on request) Weight Mounting position Mounting distance Test method Type of protection Solder bath temperature **without spark suppression approx. 18 g any rec. >1 mm A / group assembly RT III 270 °C / 5 s Tests, Regulations, Standards Fire protection requirements_ Options, Accessories none available 1) Max. excitation voltage with contact load: <4 A 2) Min. excitation voltage (guaranteed values) without previous operation _Sensitive coil _Nominal voltage _Solder terminals Number of NC contacts Number of NO contacts _Type designation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%.

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.