SIS 2 sensitive Series
1Pages

{{requestButtons}}

Catalog excerpts

SIS 2 sensitive Series - 1

SIS 2 sensitive Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contact - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distances > 10 mm) - IEC 61810-3 Type A - Double and reinforced insulation between the contacts - Contact mounting: SIS112 1 NO / 1 NC - Small external dimensions - Nominal coil power 0,2 W - Holding coil power 0,04 W - Test voltage2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC ^■ - Air and creepage distance >10 mm - Test voltage5000 V / 50 Hz / 1 min Test voltage contact open1 500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree2_ Overvoltage category III Maximal switching characteristics (EN60947-5-1) AC 1: 250 V / 6 A Load Limit Curve with Direct Current Additional Data Contact Data Contact materialAgCuNi +0,2-0,4 pm Au Type of contactSingle contact with notched crown Rated switching capacity250 VAC 6 A AC1 1500 VA Electr. Life AC1 (360 S / h) >90000 Inrush current max.30 A for 20 ms Switching voltage range5 to 250 VDC / VAC Switching current range*3 mA to 6 A Switching capacity range*40 mW to 1500 W(VA) Contact resistance (as delivered) <100 mQ / 6 V / 100 mA *Guided values Mechanical endurance Switching frequency, mechanical Response time (NO closed) Drop-out time (NC closed)_ Bounce time of NO contact Bounce time of NC contact_ >10x106 operations 12 Hz typically 15 ms typically 5 ms typically 2 ms typically 15 ms NO > 17g NC > 7g NO > 7g NC > 2g Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Thermal Resistance55 K / W Temperature limit for coil 120 °C Voltage (VDC) ^ 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range Standard Coils for Direct Current (other voltages on request) Weight Mounting position Mounting distance Test method Type of protection Solder bath temperature **without spark suppression approx. 18 g any rec. >1 mm A / group assembly RT III 270 °C / 5 s Tests, Regulations, Standards Fire protection requirements_ Options, Accessories none available 1) Max. excitation voltage with contact load: <4 A 2) Min. excitation voltage (guaranteed values) without previous operation _Sensitive coil _Nominal voltage _Solder terminals Number of NC contacts Number of NO contacts _Type designation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%.

Open the catalog to page 1

All ELESTA GmbH catalogs and technical brochures

  1. SMD4 Series

    1 Pages

  2. SMF5 Series

    1 Pages

  3. SMF3 Series

    1 Pages

  4. SMD4 Series

    1 Pages

  5. SRD SIS3

    1 Pages

  6. SRD SIM4

    1 Pages

  7. SRD SGR2

    1 Pages

  8. SIP6 Series

    1 Pages

  9. SIM4 Series

    1 Pages

  10. SIM3 Series

    1 Pages

  11. SIM2 Series

    1 Pages

  12. SIF4 Series

    1 Pages

  13. SIF6 Series

    1 Pages

  14. SIF4 Series

    1 Pages

  15. SIF3 Series

    1 Pages

  16. SIS4 Series

    1 Pages

  17. SIS3 Series

    1 Pages

  18. SIS2 Series

    1 Pages

  19. SISF2 Series

    1 Pages

  20. SIR10 Series

    1 Pages

  21. SIR8 Series

    1 Pages

  22. SID4 Series

    1 Pages

  23. SIR 8 Series

    1 Pages

  24. SIR 6 Series

    1 Pages

  25. SIR 4 Series

    1 Pages

  26. SLR 4 Series

    1 Pages

  27. SIM 2 Series

    1 Pages

  28. SIF 6 Series

    1 Pages

  29. SIF 4 Series

    1 Pages

  30. SIF 3 Series

    1 Pages

  31. SIS 6 Series

    1 Pages

  32. SIS 4 Series

    1 Pages

  33. SIS 3 Series

    1 Pages

  34. SIS 2 Series

    1 Pages

Archived catalogs