SIR 6 Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime NO Contacts - PCB relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (>10 mm), as well as output contacts to each other (>8 mm) - IEC 61810-3 Type A - Contact mounting: SIR332 3 NO / 3 NC SIR422 4 NO / 2 NC SIR512 5 NO / 1 NC - Small external dimensions - Nominal coil power 0,75 W - Holding coil power 0,22 W - Coil for railway application according EN 50155 on request Dimensions Insulation Data - Basic insulation at 250 VAC - Test voltage2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - ■ — ■ - - Air and creepage distance >8 mm - Test voltage4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC ^■ - Air and creepage distance >10 mm - Test voltage5000 V / 50 Hz / 1 min Test voltage contact open1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree2_ Overvoltage category III Maximal switching capacity (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each 4 contacts with 7,3 A each 5 contacts with 6 A each Load Limit Curve with Direct Current Contact Data Additional Data Contact material AgSnO2 + 0,2 pm Au Type of contactcrown contact Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. Life AC1(360 S / h)approx.100000 Inrush current max. 25 A for 20 ms Switching voltage range5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range*60 mW to 2 500 W(VA) Contact resistance (as delivered) <100 mQ / 6 V / 100 mA *Guided values Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact_ >10 x 106 operations 15 Hz typically 15 ms typically 4 ms typically 6 ms typically 12 ms NO > 10g NC > 6g NO > 5g NC > 2g 1) Inductive load L/R 40 ms 2) Resistive load Standard Coils for Direct Current Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature Excitation Voltage Range -40°C to +70°C (other voltages on request) Thermal Resistance 55 K / W Temperature limit for coil Mounting position Mounting distance Test method Solder bath temperature **without spark suppression Tests, Regulations, Standards Approvals cTO'us ^ lilVGh*** UL File E188953Sec. 3 Insulation class IEC 60664-1250 VAC Fire protection requirements UL 94 / V0 1) Max. excitation voltage with contact load: < 6 A 2) Min. excitation voltage (guaranteed values) without previous operation Options, Accessories Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%. none available Product Key ELESTA GmbH, Heuteilstrasse 18, Phone: +41 81 303 54 00CH - 7310 Bad Ragaz, Switzerland © Copyright 02/2019
Open the catalog to page 11 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
36 Pages
36 Pages