1. Catalogs
  2. ELESTA GmbH
  3. SIR 10 Series

SIR 10 Series
1 /1Page

SIR 10 Series

SIR 10 Series
1 /1Page

Catalog excerpts

SIR 10 Series-1

SIR 10 Series Relais Eckdaten Circuit Diagram (relay top view) Contact Lifetime NO Contacts - Printrelais mit zwangsgefuhrten Kontakten - Sichere Trennung zwischen Spule/Steuerkontakten und Ausgangskontakten (>8 mm), sowie Ausgangskontakte hintereinander (>8 mm) und linker Kontaktseite zu rechter Kontaktseite (>10 mm) - IEC 61810-3 Anwendungstyp A - Kontaktbestuckung: - Spulennennleistung 1,3 W - Halteleistung 0,39 W - Spulen fur Bahnanwendungen nach EN 50155 auf Anfrage Elektr. Lebensdauer AC1(360 S / h)ca.100000 Einschaltstrom max. 25 A fur 20 ms (andere Spannungswerte auf Anfrage) Insulation Data - Test voltage2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - ■ — ■ - - Air and creepage distance >8 mm - Test voltage4000 V / 50 Hz / 1 min Test voltage contact open1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree2_ Overvoltage category III Maximal switching capacity (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each 4 contacts with 7,3 A each 5 contacts with 6,5 A each 6 contacts with 6 A each 8 contacts with 5 A each 9 contacts with 4,2 A each Load Limit Curve with Direct Current Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) 1) Inductive load L/R 40 ms 2) Resistive load Ambient temperature Thermal Resistance Temperature limit for coil Mounting position Mounting distance Test method Solder bath temperature **without spark suppression Excitation Voltage Range Tests, Regulations, Standards Fire protection requirements Options, Accessories none available Ambient Temperature °C ^ 1) Max. excitation voltage with contact load: < 6 A 2) Min. excitation voltage (guaranteed values) without previous operation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%.

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.