SIP6 Series
1 /1Page

SIP6 Series

SIP6 Series
1 /1Page

Catalog excerpts

SIP6 Series-1

Contact data - Relay with forcibly guided contacts according to IEC 61810-3 - Application type A - Protective separation (see insulation data) - Suitable for print mounting - High switching capacity - Contact assembly SIP512: 5 NO + 1 NC, SIP422: 4 NO + 2 NC Contact data apply to contacts 11-12, 21-22, 23-24 Contact material AgSnO2 + 0,2, ..., 0,4 μm Au Contact type crown contact Rated switching power 1 500 VA 250 V / 6 A / AC-1 (max.) Electr. life time (0,1 Hz, rel. duty cycle 10%) 100 000 Inrush current 15 A for 20 ms Switching voltage range 5, ..., 250 V DC / AC Switching current range* 5 mA, ..., 6 A Switching power range* 60 mW, ..., 1 500 W (VA) Short circuit resistance of contacts** 1 000 A with pre-fuse SCPD 6 A gG / gL (fuse) Electrical life, Switching capacity, Continuous current see SIR8 series Pin dimension c Recommended drilling on PCB Circuit diagram (top view) 100 mΩ Contact data apply to contacts33-34, 43-44, 53-54, 63-64 Contact material AgSnO2 Contact type single contact Rated switching power 4 000 VA 250 V(400 V / 16 A / AC-1 (max.) Electr. life time (0,1 Hz, rel. duty cycle 10%) 250 000 Inrush current 60 A for 20 ms Switching voltage range 5, ..., 250 V DC (480 V AC) Switching current range* 10 mA, ..., 16 A Switching power range* 120 mW, ..., 4 000 W (VA) Short circuit resistance of contacts** 1 000 A with pre-fuse SCPD 16 A gG / gL (fuse) * Reference values ** Prospective short-circuit current Electrical life (NO contacts) Nominal power (typ.) Holding power (typ.) Coil limit temperature Insulation data Rated insulation voltage (IEC 60664-1) Basic insulation - Air and creepage distance (min.) - Test voltage Double or reinforced insulation - Air and creepage distance (min.) - Test voltage Double or reinforced insulation - Air and creepage distance (min.) - Test voltage Open contact: Test voltage* Creepage resistance Pollution degree Overvoltage category Insulation resistance (min.) - Test voltage 250 VAC 4 mm 2 500 Vrms / 1 min 8 mm 4 000 Vrms / 1 min 10 mm 5 000 Vrms / 1 min 1 500 Vrms / 1 min CTI 250 2 III 100 MΩ 500 VDC Mechanical data * Initial value Mechanical lifetime (min.) 10 x 106 operations Switching frequency (max.) 15 Hz Response time (NO closed) (typ.) 18 ms Drop-out time (NC closed) (typ.)* 5 ms Bounce time (typ.) NO: 8 ms / NC: 12 ms Shock resistance (16 ms) (min.) NO: 10g / NC: 8g Vibr. resistance (10-200 Hz) (min.) NO: 10g / NC: 3,5g Weight approx. 60 g Mounting position any Mounting distance (min.) 5 mm Excitation voltage range Switching capacity (IEC 61810-1) AC-1: 240 V / 16 A MAX AC-15: 240 V / 6 A MAX DC-1: 24 V / 16 A MAX DC-13: 24 V / 8 A / 0,1 Hz MAX Switching capacity (UL 508) Continuous current per contact at load of: 1 or 2 contacts 3 contacts 4 contacts Contact load limit curve (DC) * without coil wiring  Technical data Ambient temperature Thermal resistance Protection class Solder bath temperature Test method (heating) Approvals Flammability class UL File -40 °C, ..., +70 °C 40 K / W RT II 270 °C / 5 s A (group assembly) cULus, TÜV UL 94 V-0 E188 953 Sec. 4 Options, Accessories Other coil designs possible Coils accord. to EN 50155 (railway applications) possible Test conditions: - Graph 1: Contact current contacts 11-12, 21-22, 23-24: 4 A MAX, contacts 33-34, 43-44, 53-54, 63-64: 12 A MAX - Graph 2: without previous operation - Free-standing relay on PCB - Duty cycle 100% ELESTA GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Type designation Number of contacts NO Number of contacts NC Connection

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.