Overview: The document provides technical specifications for the SIM4 Series relays by ELESTA GmbH, highlighting features, dimensions, coil data, insulation data, mechanical data, and contact data.
Features: The SIM4 Series relays have forcibly guided contacts compliant with IEC 61810-3, suitable for print mounting, and offer protective separation. They are available in configurations SIM312 (2 NO + 1 NC) and SIM222 (2 NO + 2 NC).
Dimensions: Pin dimensions are specified as 1.0 x 0.3 mm and 1.0 x 0.4 mm, with a recommended PCB drilling diameter of 1.3 mm.
Coil Data: At 20°C, the nominal power is 1.0 W, with a holding power of 0.29 W. The coil limit temperature is 120°C. Various nominal voltages are provided, ranging from 5.0 VDC to 110.0 VDC, with corresponding pick-up and drop-out voltages, currents, and resistances.
Insulation Data: The rated insulation voltage is 250 VAC, with basic and reinforced insulation specifications including air and creepage distances and test voltages. The insulation resistance is at least 100 MΩ.
Mechanical Data: The relay has a mechanical lifetime of at least 10 million operations, a maximum switching frequency of 15 Hz, and specific response and drop-out times. It is resistant to shock and vibration, with a weight of approximately 25 g.
Other Data: The operating temperature range is -40°C to +70°C, with a thermal resistance of 50 K/W. The protection class is RT II, and the relay is approved by cULus and TÜV, with a flammability class of UL 94 V-0.
Contact Data: Contacts are made of AgSnO2 with a gold layer, capable of switching up to 2,000 VA. The electrical lifetime is 100,000 operations at specified conditions, with a maximum inrush current of 20 A for 20 ms.
Approvals and Options: The relays are approved by cULus and TÜV, with options for mounting rail and PCB sockets. Other coil designs are possible.
See more

Catalog excerpts

SIM4 Series-1

Contact data - Relay with forcibly guided contacts according to IEC 61810-3 - Application type A - Protective separation (see insulation data) - Suitable for print mounting - Contact assembly SIM312: 2 NO + 1 NC, SIM222: 2 NO + 2 NC Contact material AgSnO2 + 0,2, ..., 0,4 μm Au Contact type crown contact Rated switching power 2 000 VA 250 V / 8 A / AC-1 (max.) Electr. life time (0,1 Hz, rel. duty cycle 10%) 100 000 Inrush current 20 A for 20 ms Switching voltage range 5, ..., 250 V DC / AC Switching current range* 10 mA, ..., 8 A Switching power range* 60 mW, ..., 2 000 W (VA) Contact resistance as new (max.) 100 mΩ Short circuit resistance of contacts** 1 000 A with pre-fuse SCPD 10 A gG / gL (fuse) Circuit diagram (top view) * Reference values ** Prospective short-circuit current Insulation data Electrical life (NO contacts) Pin dimension b Pin dimension c Recommended drilling on PCB Rated insulation voltage (IEC 60664-1) Basic insulation - Air and creepage distance (min.) - Test voltage Double or reinforced insulation - Air and creepage distance (min.) - Test voltage Double or reinforced insulation - Air and creepage distance (min.) - Test voltage Open contact: Test voltage* Creepage resistance Pollution degree Overvoltage category Insulation resistance (min.) - Test voltage Nominal power (typ.) Holding power (typ.) Coil limit temperature 250 VAC 4 mm 2 500 Vrms / 1 min 5,5 mm 4 000 Vrms / 1 min 14 mm 5 000 Vrms / 1 min 1 500 Vrms / 1 min CTI 250 2 III 100 MΩ 500 VDC * Initial value Switching capacity (IEC 61810-1) AC-1: 240 V / 8 A MAX AC-15: 240 V / 3 A MAX DC-1: 24 V / 8 A MAX DC-13: 24 V / 6 A / 0,1 Hz MAX Switching capacity (UL 508) Continuous current per contact at load of: 1 or 2 contacts 3 contacts Contact load limit curve (DC) Excitation voltage range Mechanical data Mechanical lifetime (min.) 10 x 106 operations Switching frequency (max.) 15 Hz Response time (NO closed) (typ.) 8 ms Drop-out time (NC closed) (typ.)* 4 ms Bounce time (typ.) NO: 6 ms / NC: 12 ms Shock resistance (16 ms) (min.) NO: 10g / NC: 2,5g Vibration resistance (10-200 Hz) (min.) NO: 10g / NC: 1g Weight approx. 25 g Mounting position any Mounting distance (min.) 5 mm * without coil wiring  Other data Ambient temperature Thermal resistance Protection class Solder bath temperature Test method (heating) Approvals Flammability class UL File -40 °C, ..., +70 °C 50 K / W RT II 270 °C / 5 s A (group assembly) cULus, TÜV UL 94 V-0 E188 953 Sec. 3 Options, Accessories Mounting rail socket PCB socket Other coil designs Test conditions: - Graph 1: Contact current 6 A MAX - Graph 2: without previous operation - Free-standing relay on PCB - Duty cycle 100% ELESTA GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Type designation Number of contacts NO Number of contacts NC Connection technology Nomi