Insulation Data:
  • Double or reinforced insulation at 250 VAC with air and creepage distances greater than 5.5 mm and 14 mm respectively.
  • Test voltages are 4000 V and 5000 V at 50 Hz for 1 minute.
  • Contact open test voltage is 1500 V at 50 Hz for 1 minute.
  • Creepage resistance is CTI 250, pollution degree 2, and overvoltage category III.
  • Insulation resistance at Up 500 VDC is greater than 100 MΩ.
Additional Data:
  • Mechanical endurance exceeds 10 million operations with a switching frequency of 15 Hz.
  • Response time for NO contact is typically 10 ms, and drop-out time for NC contact is typically 3 ms.
  • Bounce times are 6 ms for NO contact and 12 ms for NC contact.
  • Shock and vibration resistance are specified for NO and NC contacts.
  • Ambient temperature range is -40°C to +70°C, with a thermal resistance of 55 K/W.
  • Coil temperature limit is 120°C, and the relay weighs approximately 20 g.
  • Mounting position is flexible, with a recommended distance of more than 5 mm.
  • Type of protection is RT II, and solder bath temperature is 270°C for 5 seconds.
Tests, Regulations, Standards:
  • Approvals include UL File E188953 Sec. 3.
  • Insulation class is IEC 60664-1 250 VAC, and fire protection requirements are UL 94 / V0.
  • Standards include IEC 61810-1 and IEC 61810-3.
Contact Data:
  • Contact material is AgSnO2 with 0.2 μm Au, and type of contact is crown contact.
  • Rated switching capacity is 250 VAC 8 A AC1 2000 VA, with an electrical life of approximately 100,000 operations.
  • Inrush current is a maximum of 20 A for 20 ms.
  • Switching voltage range is 5 to 250 VDC/VAC, and switching current range is 10 mA to 8 A.
  • Contact resistance as delivered is ≤100 mΩ / 6 V / 100 mA.
Standard Coils for Direct Current:
  • Nominal voltages range from 5 VDC to 110 VDC, with specified pick-up and drop-out voltages, nominal current, and resistance values at 20°C.
Relay Key Data:
  • PCB relay with forcibly guided contacts and protective separation between coil and contacts.
  • Contact mounting is SIM112 with 1 NO and 1 NC contact.
  • Nominal coil power is 0.5 W, and holding coil power is 0.15 W.
See more

Catalog excerpts

SIM 2 Series-1

SIM 2 Series Relay Key Data Circuit Diagram (relay top view) Contact Lifetime for NO Contact - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (air and creepage distance >14 mm); protective separation between left and right contact side (air and creepage distance >5,5 mm) - IEC 61810-3 Type A - Contact mounting: SIM112 1 NO / 1 NC - Small external dimensions - Nominal coil power 0,5 W - Holding coil power 0,15 W Insulation Data - Double or reinforced insulation at 250 VAC - ■ — ■ - - Air and creepage distance >5,5 mm - Test voltage4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC ^■ - Air and creepage distance >14 mm - Test voltage5000 V / 50 Hz / 1 min Test voltage contact open1 500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree2_ Overvoltage category III Additional Data Maximal switching capacity (DIN EN 60947-5-1, Tab. C2) AC 1: 250 V / 8 A Load Limit Curve with Direct Current crown contact Rated switching capacity Mechanical endurance Switching frequency, mechanical Response time (NO closed) Drop-out time (NC closed)_ Bounce time of NO contact Bounce time of NC contact_ Switching voltage range >10 x 106 operations 15 Hz typically 10 ms typically 3 ms typically 6 ms typically 12 ms NO > 10g NC > 2,5g NO > 10g NC > 1g 1) Inductive load L/R 40 ms 2) Resistive load Switching current range* Switching capacity range*_ Contact resistance (as delivered) Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature Excitation Voltage Range Thermal Resistance *Guided values Temperature limit for coil Standard Coils for Direct Current Mounting position (other voltages on request) Mounting distance Test method Solder bath temperature **without spark suppression Tests, Regulations, Standards UL File E188953Sec. 3 Insulation class IEC 60664-1250 VAC Fire protection requirements UL 94 / V0 1) Max. excitation voltage with contact load: <6 A 2) Min. excitation voltage (guaranteed values) without previous operation Options, Accessories none available Nominal voltage Solder terminals Type designation Single relay on print, no heat accumulation due to surrounding components with self-heating, duty cycle 100%.